Bifurcation Optimisation Stent System (BiOSS Lim) with sirolimus elution: results from porcine coronary artery model.
MedLine Citation:
PMID:  21930466     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Aims: The optimal treatment strategy for coronary bifurcation lesions is still unknown. The BiOSS Lim stents (Bifurcation Optimisation Stent System) is a novel dedicated bifurcation stent introduced over a single wire in to the main vessel, covered with biodegradable polymer and sirolimus. It has wider proximal and narrower distal parts. The aim of the study was to assess applicability of the the BiOSS Lim stent in a porcine coronary model. Methods and results: A total of 14 BiOSS Lims were implanted in normal non-atherosclerotic porcine coronary bifurcations of 14 animals (six stents for 28 days, eight stents for 90 days) using 1.1:1.0 stent-to-artery ratio. Stent geometry and morphology were evaluated by Faxitron imagery (Faxitron Bioptics, LLC, IL, USA). Vascular effects were assessed based on angiographic and histological analysis. Analysis of Faxitron images revealed no major abnormalities except two struts fractures at the place of connection between the mid-portion and proximal wider part of the stent. Histomorphometry showed decreased area stenosis and intimal thickness at 90 days compared with the 28 days cohort. The inflammatory scores were low (<1) at both time points and struts endothelialisation was completed at 28 days. Conclusions: The novel BiOSS Lim stent demonstrates good short- and mid-term vascular effects in a porcine coronary bifurcation model.
Authors:
Dobrin Vassilev; Robert Gil; Krzysztof Milewski
Related Documents :
7752356 - Laparoscopically assisted penile revascularization for vasculogenic impotence.
15745296 - Vasoplegic syndrome after off-pump coronary artery bypass surgery: an unusual complicat...
16844886 - Minor depression as a cardiac risk factor after coronary artery bypass surgery.
11687996 - Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery:...
9555776 - High anti-cytomegalovirus (cmv) igg antibody titer is associated with coronary artery d...
11583676 - Multifocal electroretinograms in patients with branch retinal artery occlusion.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology     Volume:  7     ISSN:  1969-6213     ISO Abbreviation:  EuroIntervention     Publication Date:  2011 Sep 
Date Detail:
Created Date:  2011-09-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101251040     Medline TA:  EuroIntervention     Country:  France    
Other Details:
Languages:  eng     Pagination:  614-20     Citation Subset:  IM    
Affiliation:
National Heart Hospital, Sofia, Bulgaria.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Implantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score ...