Document Detail

Bentall procedure 39 years after implantation of a Starr-Edwards aortic caged-ball-valve prosthesis.
Jump to Full Text
MedLine Citation:
PMID:  20298579     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic--no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial operation, we performed a Bentall-Procedure to treat an aortic ascendens aneurysm with diameters of 6.0 x 6.5 cm: we explanted the old Starr-Edwards-aortic-caged-ball-valve-prosthesis and replaced the ascending aorta with a 29 mm St.Jude Medical aortic-valve-composite-graft and re-implanted the coronary arteries.This case represents the longest time period between Starr-Edwards-caged-ball-valve-prosthesis-implantation and Bentall-reoperation, thereby confirming the excellent durability of this valve.
Authors:
Jan D Schmitto; Philipp Ortmann; Aron F Popov; Kasim O Coskun; Hanna Schotola; Martin Friedrich; Christoph H Wiese; Christian Sohns; Suyog A Mokashi; Vassilios N Didilis; Friedrich A Schoendube
Related Documents :
3945089 - Experimental evaluation of porcine-valved conduits processed with a calcium-retarding a...
646489 - The prevention of bypass enteritis after jejunoileal bypass for morbid obesity.
23466839 - Application of the willis covered stent using the telescopic technique for the treatmen...
7444829 - New technique for construction of tissue heart valves.
23769649 - Pulmonary edema predictive scoring index (pepsi), a new index to predict risk of reperf...
1729819 - Hemodynamic evaluation of the carbomedics prosthetic heart valve in the aortic position...
16285999 - Inter-study reproducibility of 3d volume selective fast spin echo sequence for quantify...
8727509 - Arterial gene transfer for therapeutic angiogenesis in patients with peripheral artery ...
19135389 - A braunwald-cutter valve: a mitral prosthesis at 33 years.
Publication Detail:
Type:  Case Reports; Journal Article     Date:  2010-03-18
Journal Detail:
Title:  Journal of cardiothoracic surgery     Volume:  5     ISSN:  1749-8090     ISO Abbreviation:  J Cardiothorac Surg     Publication Date:  2010  
Date Detail:
Created Date:  2010-03-29     Completed Date:  2010-05-18     Revised Date:  2013-05-29    
Medline Journal Info:
Nlm Unique ID:  101265113     Medline TA:  J Cardiothorac Surg     Country:  England    
Other Details:
Languages:  eng     Pagination:  12     Citation Subset:  IM    
Affiliation:
Department of Thoracic-, Cardiac- and Vascular Surgery, Georg-August-University of Goettingen, Goettingen, Germany. schmitto@med.uni-goettingen.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aortic Valve Insufficiency / surgery*
Blood Vessel Prosthesis Implantation / methods*
Device Removal
Heart Valve Prosthesis*
Heart Valve Prosthesis Implantation / methods*
Humans
Male
Middle Aged
Prosthesis Design
Reoperation
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): J Cardiothorac Surg
ISSN: 1749-8090
Publisher: BioMed Central
Article Information
Download PDF
Copyright ?2010 Schmitto et al; licensee BioMed Central Ltd.
open-access:
Received Day: 2 Month: 11 Year: 2009
Accepted Day: 18 Month: 3 Year: 2010
collection publication date: Year: 2010
Electronic publication date: Day: 18 Month: 3 Year: 2010
Volume: 5First Page: 12 Last Page: 12
Publisher Id: 1749-8090-5-12
PubMed Id: 20298579
DOI: 10.1186/1749-8090-5-12

Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis
Jan D Schmitto12 Email: schmitto@med.uni-goettingen.de
Philipp Ortmann1 Email: ph.ortmann@gmx.de
Aron F Popov1 Email: popov@med.uni-goettingen.de
Kasim O Coskun1 Email: dr_coskunok@yahoo.de
Hanna Schotola3 Email: hschotola@med.uni-goettingen.de
Martin Friedrich1 Email: m.friedrich@med.uni-goettingen.de
Christoph H Wiese3 Email: wiese.christoph@klinik.uni-regensburg.de
Christian Sohns4 Email: christian.sohns@gmx.de
Suyog A Mokashi2 Email: smokashi@partners.org
Vassilios N Didilis1 Email: vdidilis@med.duth.gr
Friedrich A Schoendube1 Email: schondube@med.uni-goettingen.de
1Department of Thoracic-, Cardiac- and Vascular Surgery, Georg-August-University of Goettingen, Goettingen, Germany
2Division of Cardiac Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
3Department of Anesthesiology, Georg-August-University of Goettingen, Goettingen, Germany
4Department of Cardiology and Pneumology, Georg-August-University of Goettingen, Goettingen, Germany

Case report

In 1967, a 23-year-old male presented with severe aortic valve regurgitation. Given the symptoms were refractory to medical management, the decision was made to replace the dysfunctional aortic valve. At that time, 39 years ago, standard care was to implant a Starr-Edwards-caged-ball-valve-prosthesis in aortic position (Figure 1). The surgery and post-operative course were without complications and the patient recovered well after the operation. However, four years later, the ball was damaged and contained thromboembolic formations. Therefore, the decision was made to replace the elastic ball with a structurally similar silicone ball. For the next four decades, the patient remained asymptomatic - no restrictions on his lifestyle and without any complications.

In January 2006, 39 years after the initial operation, the patient became increasingly symptomatic for six weeks - progressive dyspnea and chest pain (angina-pectoris according to CCS III). Myocardial scintigraphy and coronary angiography were performed and revealed diffuse, but insignificant atherosclerosis (possibly explaining his acute deterioration). An aortic angiogram revealed high grade post-valvular aneurysm of the ascending aorta. This was also proven on computed tomography of the thorax: the dimensions of the aortic aneurysm were 6.0 ? 6.5 cm, with normal physiological diameters distally, with no evidence of an aortic dissection. Additionally, echocardiography demonstrated: middle-grade dilatation of the left atrium, high-grade dilatation of the left ventricle and a left ventricular ejection fraction (EF) severely reduced to 30%. The functionality of the prosthesis presented borderline values, but regular flow.

Operative intervention was once again indicated. In February, we decided to perform a Bentall-Procedure: therefore, we explanted the 39-year-old Starr-Edwards-aortic-caged-ball-valve-prosthesis (Figure 2) and replaced the ascending aorta with a 29 mm St. Jude Medical aortic-valve-composite-graft and re-implanted the coronary arteries. Postoperatively, the patient developed AV-block III?, therefore a DDD-pacemaker was implanted four days later (Figure 3). The remainder of the postoperative course was uneventful and he was discharged home on postoperative day 12 with stable hemodynamics. On histological analysis of the aortic wall, a large calcification, bulky mucoid degeneration and destruction of elastic fibres was found.

Of note, this coincidentally is the latest Bentall-procedure after 39 years of survival of a Starr-Edwards-valve implantation found in the literature [1].


Discussion

The Starr-Edwards caged-ball-valve prosthesis (Edwards Lifesciences, Nyon, Switzerland) was implanted routinely for many years in heart centers worldwide. By 1967, nearly 2000 Starr-Edwards-valves had been implanted [2] - establishing the caged-ball-valve prosthesis as the standard surgical treatment for aortic and mitral valve disease. Due to the fact that the Starr-Edwards valves showed a high ventriculo-aortic outflow pressure gradient and also a higher incidence of poststenotic dilations of the ascending aorta in long-term follow-up, newer models had to be developed to increase the valve's hemodynamics. Therefore, new valve prostheses were manufactured using several different materials, including: pericardium, fasciae latae, and dura mater. In the 1960s, Binet and colleagues began to develop tissue valves [2]. Then in 1964, Duran and Gunning (Oxford, England) replaced an aortic valve in a patient using a xenograft porcine aortic valve [3]. The early results of the Starr-Edwards-valve were good [1], however after a few years these patients developed signs of chronic heart failure, due to the poor hemodynamics of the valve. In addition, the caged-ball-valves showed a higher incidence of thrombembolic complications compared to the newer valve developments. However, there is one large series reporting on 2,247 aortic valve replacements with Starr-Edwards prostheses implanted between 1960 and 1997 [1]. In this study, Kaplan-Meier (KM) survival at 10 years was 53% for Aortic Valve Replacement, 23% at 20 years, 8% at 30 years and 4% at 40 years. Even in this study no Bentall operation after such a long time period was presented. We therefore present the longest time period between Starr-Edwards-caged-ball-valve-prothesis implantation and Bentall reoperation of a long-term survivor, thereby confirming the excellent durability of this valve.


Competing interests

The authors declare that they have no competing interests.


Authors' contributions

All authors read and approved the final manuscript.


Consent

Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.


References
Gao G,Wu Y,Grunkemeier GL,Furnary AP,Starr AJ,Forty-year survival with the Starr-Edwards heart valve prosthesisHeart Valve DisYear: 2004131916 discussion 96.
Cohn LH,Cardiac Surgery Textbook "Cardiac surgery in the adult" Stephenson L WiHistory of Cardiac SurgeryYear: 20083New York: McGraw-Hill328
Binet JP,Carpentier A,Langlois J,Implantation de valves heterogenes dans le traitment des cardiopathies aortiquesC R Acad Sci ParisYear: 19652615733

Figures

[Figure ID: F1]
Figure 1 

Pre-operative chest X-ray with the Starr-Edwards-caged-ball-valve in aortic position.



[Figure ID: F2]
Figure 2 

Explanted Starr-Edwards-caged-ball-valve 39 years after implantation.



[Figure ID: F3]
Figure 3 

Post-operative chest X-ray after successfully performed Bentall- and Pacemaker-implantation.



Article Categories:
  • Case report


Previous Document:  EEG alpha phenotypes: linkage analyses and relation to alcohol dependence in an American Indian comm...
Next Document:  Novel model for end-neuroma formation in the amputated rabbit forelimb.