Bench comparative evaluation of a new generation and standard helmet for delivering non-invasive ventilation.
MedLine Citation:
PMID:  23223773     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: To evaluate the performance of a new helmet (NH) recently introduced into clinical use relative to that of the standard helmet (SH) in terms of delivering non-invasive continuous positive airway pressure (nCPAP) and pressure support ventilation (nPSV). DESIGN: This was a bench study using a mannequin connected to an active lung simulator. The SH was fastened to the mannequin by armpit braces, which are not needed to secure the NH. MEASUREMENTS: The inspiratory and expiratory variations in nCPAP delivered with two different simulated efforts (Pmus), were determined relative to the preset CPAP level. nPSV was applied at two simulated respiratory rates (RR) and two cycling-off flow thresholds. We measured inspiratory trigger delay (Delay(trinsp)), expiratory trigger delay (Delay(trexp)), time of synchrony (Time(sync)), trigger pressure drop (ΔP (trigger)), airway pressure-time product during the triggering phase (PTPt), the initial 200 ms from the onset of the ventilator pressurization (PTP(200)), and the initial 300 and 500 ms from the onset of the simulated effort; this two latter parameters were expressed as the percentage of the area of ideal pressurization (PTP(300-index) and PTP(500-index), respectively). RESULTS: In nCPAP, at both Pmus, the differences between the two interfaces at both Pmus were small and clinically irrelevant. In nPSV, regardless of the setting, NH resulted in significantly smaller trigger delays, ΔP (trigger), and PTPt. Time(sync), PTP(200), PTP(300-index), and PTP(500-index) were also significantly higher with the NH compared to the SH, irrespective of the setting. CONCLUSIONS: Compared to the SH, the NH is equally effective in delivering nCPAP and more effective in delivering nPSV, and it is used to avoid the need for armpit braces.
Authors:
C Olivieri; R Costa; G Spinazzola; G Ferrone; F Longhini; G Cammarota; G Conti; P Navalesi
Related Documents :
9495433 - Small-dose fentanyl: optimal time of injection for blunting the circulatory responses t...
11008443 - Cardiopulmonary side-effects and pharmacokinetics of an emulsion of propofol (disopriva...
11439723 - Power spectral analysis imperfectly informs changes in sympathetic traffic during acute...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-6
Journal Detail:
Title:  Intensive care medicine     Volume:  -     ISSN:  1432-1238     ISO Abbreviation:  Intensive Care Med     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-10     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7704851     Medline TA:  Intensive Care Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Anesthesia and Intensive Care Medicine, Maggiore della Carità University Hospital, Novara, Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Automated sedation outperforms manual administration of propofol and remifentanil in critically ill ...
Next Document:  Prediction of fluid responsiveness in severe preeclamptic patients with oliguria.