Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery.
MedLine Citation:
PMID:  10794327     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To evaluate the accuracy of a new pulse contour method of measuring cardiac output in critically ill patients. DESIGN: A prospective criterion standard study. SETTING: Cardiac surgery intensive care unit in a university hospital. PARTICIPANTS: Nineteen cardiac surgery patients requiring intensive care treatment with pulmonary artery catheters after surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The pulse contour cardiac output monitor uses transpulmonary bolus thermodilution measurements to calibrate the system. In each patient, the pulse contour cardiac output values were compared with conventional thermodilution. The method described by Bland and Altman and linear regression analysis were used for comparison. The mean difference (bias) +/- standard deviation of differences (precision) was 0.31 +/- 1.25 L/min for pulmonary bolus thermodilution cardiac output versus pulse contour cardiac output and 0.21 +/- 0.73 L/min for pulmonary bolus thermodilution cardiac output versus transpulmonary bolus thermodilution cardiac output. Linear regression (correlation) analyses were pulse contour cardiac output = 0.97 thermodilution + 0.53 (r = 0.88), and transpulmonary cardiac output = 0.87 thermodilution + 1.09 (r = 0.96). There was a small increase 60 minutes after recalibration but not a statistically significant difference between pulse contour cardiac output and pulmonary bolus thermodilution cardiac output (p = 0.52). CONCLUSIONS: Bias and precision are acceptable, and the system provides results that agree with conventional thermodilution. This study demonstrates the clinical applicability of the pulse contour cardiac output monitoring system.
Authors:
C Zöllner; M Haller; M Weis; K Mörstedt; P Lamm; E Kilger; A E Goetz
Related Documents :
10410287 - Diagnosis and management of cardiac tamponade in the era of echocardiography.
10070187 - Left ventricular apical diastolic collapse: an unusual echocardiographic marker of post...
12847947 - Transesophageal echocardiography as an alternative for the assessment of the trauma and...
15541977 - 'tamponade' following cardiac surgery: terminology and echocardiography may both mislead.
16234887 - The history of the coronary care unit.
3871237 - Myocardial surgical revascularization after streptokinase treatment for acute myocardia...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of cardiothoracic and vascular anesthesia     Volume:  14     ISSN:  1053-0770     ISO Abbreviation:  J. Cardiothorac. Vasc. Anesth.     Publication Date:  2000 Apr 
Date Detail:
Created Date:  2000-06-30     Completed Date:  2000-06-30     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9110208     Medline TA:  J Cardiothorac Vasc Anesth     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  125-9     Citation Subset:  IM    
Affiliation:
Department of Anesthesiology, Ludwig-Maximilians University of Munich, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Calibration
Cardiac Output / physiology*
Cardiac Surgical Procedures*
Catheterization, Swan-Ganz
Female
Humans
Intensive Care
Male
Middle Aged
Monitoring, Intraoperative / methods*
Prospective Studies
Regression Analysis
Thermodilution