Document Detail


Bactericidal effect of a Nd:YAG laser on Enterococcus faecalis at pulse durations of 15 and 25 ms in dentine depths of 500 and 1,000 μm.
MedLine Citation:
PMID:  20809081     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
The success of endodontic treatment depends on the effective elimination of microorganisms from the root canal, and lasers provide more effective disinfection than conventional treatment using rinsing solutions. The objective of this in vitro study was to determine the bactericidal effect of laser irradiation in dentine of various depths at a wavelength of 1,064 nm and pulse durations of 15 and 25 ms. A total of 90 dentine slices were cut from bovine incisors and divided into two groups (45 slices each) of thickness 500 and 1,000 μm. All were inoculated with a suspension of Enterococcus faecalis (5.07 × 10(9) bacteria/ml). Based on the clinically accepted dose (approximately 300 J/cm(2)), the following laser settings were chosen for this study: 1.75 W, 0.7 Hz for 4 s, three repetitions. The two groups were divided into two subgroups of 15 slices each to be irradiated with pulse durations of 15 and 25 ms. The remaining 15 slices per group were not irradiated to serve as a control. After irradiation, the colony-forming units (CFU) were counted and evaluated. To determine the bactericidal effect of irradiation with different pulse durations, the results in the different groups were compared statistically. For all irradiated subgroups a bactericidal effect was observed at pulse durations of 15 and 25 ms (p=0.0085 and p<0.0001). The corresponding average log kills were 0.29 (15 ms) and 0.52 (25 ms) for 500 μm and 0.15 and 0.3 for 1,000 μm, respectively. The results of this in vitro study showed that Nd:YAG laser irradiation with a pulse duration of 15 ms eliminated an average of 49% and 29% of E. faecalis at dentine depths of 500 μm and 1,000 μm, respectively, and irradiation with a pulse duration of 25 ms eliminated 70% (500 μm) and 50% (1,000 μm). However, these values are lower than those achieved with the established protocol using microsecond pulses.
Authors:
René Franzen; Norbert Gutknecht; Silke Falken; Nicole Heussen; Jörg Meister
Publication Detail:
Type:  Journal Article     Date:  2010-08-31
Journal Detail:
Title:  Lasers in medical science     Volume:  26     ISSN:  1435-604X     ISO Abbreviation:  Lasers Med Sci     Publication Date:  2011 Jan 
Date Detail:
Created Date:  2010-11-16     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611515     Medline TA:  Lasers Med Sci     Country:  England    
Other Details:
Languages:  eng     Pagination:  95-101     Citation Subset:  IM    
Affiliation:
Department of Conservative Dentistry, Periodontology and Preventive Dentistry, Medical Faculty, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany. rfranzen@ukaachen.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Microtensile bond strength of an etch-and-rinse adhesive to enamel and dentin after Er:YAG laser pre...
Next Document:  Status epilepticus attributed to moxifloxacin in an adolescent patient with spina bifida occulta.