Document Detail


Avoiding early partial valve thrombosis of the Pericarbon Freedom stentless valve.
MedLine Citation:
PMID:  17315388     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Pericardial stentless valve prostheses have shown excellent results in aortic valve replacement. However, due to flexibility of the prosthetic material, immobilization and subsequent partial valve thrombosis may occur in case of non-symmetric sinuses of Valsalva. This report details an implantation technique designed to prevent stress on the non-coronary cusp of pericardial stentless prostheses, thereby avoiding this problem.
Authors:
Sven Beholz; Wolfgang E Konertz
Related Documents :
23818438 - Neurovascular anatomic relationships to arthroscopic posterior and transseptal portals ...
9654658 - Thrombolytics and left-sided prosthetic valve thrombosis. a case report.
23267698 - Carotid atherosclerosis and relation to growth of infrarenal aortic diameter and follow...
24721658 - Computer-supported diagnosis for endotension cases in endovascular aortic aneurysm repa...
21923248 - Craniocervical arterial dissections as sequelae of chiropractic manipulation: patterns ...
11546888 - Endovascular treatment of unruptured aneurysms.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Journal of heart valve disease     Volume:  16     ISSN:  0966-8519     ISO Abbreviation:  J. Heart Valve Dis.     Publication Date:  2007 Jan 
Date Detail:
Created Date:  2007-02-23     Completed Date:  2007-03-06     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9312096     Medline TA:  J Heart Valve Dis     Country:  England    
Other Details:
Languages:  eng     Pagination:  91-2     Citation Subset:  IM    
Affiliation:
Department of Cardiovascular Surgery, Charité-University Medicine Berlin, Germany. sven.beholz@charite.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Aortic Valve
Bioprosthesis / adverse effects*
Heart Valve Prosthesis / adverse effects*
Heart Valve Prosthesis Implantation / instrumentation,  methods*
Humans
Suture Techniques
Thrombosis / etiology,  prevention & control*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve.
Next Document:  Massive mitral and pulmonary valve incompetence in a patient with left ventricular, non-compacted my...