Averaging of strongly varying signals.
MedLine Citation:
PMID:  11458769     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Forces acting at the hip joint during a given activity often vary much between trials and subjects. Large variations are also encountered in many other biomechanical signals. Arithmetic mean curves then lead to falsified results, especially if extreme values occur at very different times. A method was developed for calculating a typical curve from such varying, time dependent signals. All cycle times are first averaged and the signals are then more and more smoothed using Fourier series with decreasing numbers of harmonics. The remaining extrema are analysed to decide whether they are typical for all curves or not. This is done by systematically cutting off a varying number of extrema at the beginning or end of all curves. After this an equal number of extrema remains in all curves. These extrema are then shifted to average positions in time, i.e. the times between consecutive extrema are compressed or expanded, and the standard deviation of all curves is calculated. The combination of cut off extrema which results in the smallest standard deviation is then used further on. The same time distortions are applied to the original curves and their arithmetic mean finally results in the typical signal. This procedure is well suited for averaging hip contact forces and other varying signals as long as their complexity and variation is not extremely large.
Authors:
G Bergmann; R Gandini; H Ruder
Related Documents :
23771419 - Behavioral and plasma monoamine responses to high-speed railway noise stress in mice.
24352829 - Toxicological effects of the sunscreen uv filter, benzophenone-2, on planulae and in vi...
23049779 - Effect of blue light on endogenous isopentenyladenine and endoreduplication during phot...
24423559 - Effect of light exposure on sensorial quality, concentrations of bioactive compounds an...
23112479 - Flexural strength of a composite resin light cured with different exposure modes and im...
24506809 - Light protection of the skin after photodynamic therapy reduces inflammation; an unblin...
16684149 - Into the twilight zone: the complexities of mesopic vision and luminous efficiency.
6709369 - Two systems in the detection of visual motion.
22990689 - Transient visual disturbances in adolescents: migrainous feature or headache-accompanie...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Biomedizinische Technik. Biomedical engineering     Volume:  46     ISSN:  0013-5585     ISO Abbreviation:  Biomed Tech (Berl)     Publication Date:  2001 Jun 
Date Detail:
Created Date:  2001-07-18     Completed Date:  2001-08-30     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  1262533     Medline TA:  Biomed Tech (Berl)     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  168-71     Citation Subset:  IM    
Affiliation:
Dept. of Astronomy and Astrophysics, University Tübingen, Germany. bergmann@biomechanik.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Arthroplasty, Replacement, Hip
Biomechanics
Fourier Analysis
Hip Joint / physiopathology*
Humans
Mathematical Computing
Postoperative Complications / physiopathology
Range of Motion, Articular / physiology*
Signal Processing, Computer-Assisted*
Weight-Bearing / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Miniaturization capable, very sensitive polarimeter as detector of an implantable glucose probe. I. ...
Next Document:  Evaluation of hydroxyapatite-coated Schanz screws in the Heidelberg external fixation system (HEFS)