Automated versus manual detection of left ventricular wall motion abnormalities by gated blood pool SPECT.
MedLine Citation:
PMID:  19472633     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The purpose of this investigation was to describe the rationale and implementation of new totally automated algorithms to compute global and regional left ventricular (LV) function measurements from blood pool (BP) gated SPECT data and to test the hypothesis that automated calculations are as accurate as manual calculations for detecting global and regional LV wall motion abnormalities when compared to independent cardiac magnetic resonance (CMR) measurements. From an Institutional Review Board approved retrospective review of data for 43 patients (age 58 +/- 13 years; 82% males; 59% with CHF; 59% with prior MI) evaluated for cardiac disease, CMR data were analyzed along with automated and manual calculations of BP data. There was no difference among global LV EF values (ANOVA p = 0.90) and strong correlation between automated (r = 0.96, p < 0.0001) and manual (r = 0.95, p < 0.0001) global LV EFs versus CMR, with no significant trends or biases. There was "very good agreement" of automated (kappa = 0.91) and manual (kappa = 0.86) discriminations of cases with LV EF < 50% versus CMR. Detection of LV segments with abnormal regional wall motion was equally accurate (p = 0.68) for automated and manual processings of BP data [ROC areas = 87(+/- 2%) versus 86(+/- 2%)]. The authors conclude that automated and manual computations were equivalent to each other and accurate at identifying both global and regional LV wall motion abnormalities.
Authors:
Kenneth J Nichols; Andrew Van Tosh; Yi Wang; Christopher J Palestro; Nathaniel Reichek
Related Documents :
23382613 - Bioprosthetic aortic valve changes late after insertion of a left ventricular assist de...
17448373 - Phase analysis of gated myocardial perfusion single-photon emission computed tomography...
21928203 - The value of ecg parameters in estimating myocardial injury and establishing prognosis ...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Medical physics     Volume:  36     ISSN:  0094-2405     ISO Abbreviation:  Med Phys     Publication Date:  2009 Apr 
Date Detail:
Created Date:  2009-05-28     Completed Date:  2009-07-01     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1251-7     Citation Subset:  IM    
Affiliation:
Division of Nuclear Medicine and Molecular Imaging, North Shore Long Island Jewish Health System, 270-05 76th Avenue, New Hyde Park, New York 11040, USA. knichols@lij.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Automation
Blood Volume
Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography / instrumentation*,  methods*
Female
Humans
Magnetic Resonance Imaging / methods
Male
Middle Aged
ROC Curve
Radionuclide Imaging / methods
Reproducibility of Results
Retrospective Studies
Tomography, Emission-Computed, Single-Photon / methods*
Ventricular Function, Left*