Document Detail


Automated office versus home measurement of blood pressure in the assessment of morning hypertension.
MedLine Citation:
PMID:  22218221     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: To compare the quality and accuracy of morning blood pressure (BP) readings as taken by automated office BP (AOBP) and morning home BP (mHBP) techniques using morning ambulatory BP (mABP) measurements as the gold standard. METHODS: A total of 139 individuals were included, 70 men and 69 women, mean age 53±13 years. The average AOBP readings as measured using a Microlife Watch BP office device taking triplicate automated simultaneous readings of both arms were compared with mHBP monitored on 6 routine days, using a validated automated electronic device. Both modalities were also compared with the ambulatory readings of the 3 h of waking (mABP3h). RESULTS: The AOBP values were slightly higher than the mABP3h (mean difference 8.2 mmHg, 95% limits of agreement, -18.8 to 35.2 mmHg for the systolic BP and mean difference 4.3 mmHg, 95% limits of agreement, -15.3 to 23.9 mmHg for the diastolic BP). Systolic and diastolic AOBP readings correlated with mABP3h (r=0.66, P=0.001 and r=0.64, P=0.001, respectively). Agreement was fair between AOBP and mHBP in the detection of morning hypertensive patients (agreement 70%, κ=0.32) as compared with AOBP and mABP3h (agreement 67%, κ=0.32) and mHBP and mABP3h (agreement 65%, κ=0.31). CONCLUSION: The AOBP technique could replace mHBP monitoring in the assessment of morning BP, as it provides comparable data in relation to the awake ambulatory BP. Given the simplicity of this method, it could be more readily applied in a larger number of individuals.
Authors:
Emmanuel A Andreadis; Epameinondas T Angelopoulos; Athanasios P Tsakanikas; Gerasimos D Agaliotis; Sofia D Kravvariti; George P Mousoulis
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-1-2
Journal Detail:
Title:  Blood pressure monitoring     Volume:  -     ISSN:  1473-5725     ISO Abbreviation:  -     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-1-5     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
3rd Department of Internal Medicine, Evangelismos General Hospital, Athens, Greece.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Morning hypertension in chronic kidney disease is sustained type, but not surge type.
Next Document:  Wave localization in two-dimensional porous phononic crystals with one-dimensional aperiodicity.