Document Detail


Automated external defibrillation by first-responders.
MedLine Citation:
PMID:  20738045     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This review examines whether the use of automated external defibrillators by first-responders improves the survival of adults who suffer cardiopulmonary arrest. We also examined the risks associated with these devices, based on a review of the literature using the standard Prescrire methodology. Automated external defibrillators detect ventricular fibrillation with almost perfect sensitivity and specificity. Several studies showed that the use of automated external defibrillators by trained first-responders is associated with increased survival among patients who suffer out-of-hospital cardiac arrest in public places. A retrospective study suggests that installing automated external defibrillators in public places would only allow about one-fifth of all victims of cardiac arrest to be treated; this would increase the average survival rate after cardiac arrest from about 5% to 6.5%. The main risks associated with these devices are burns to the patient's skin at the electrode contact points, and inappropriate shock to the user--a rare occurrence. Interactions between automated external defibrillators and implantable defibrillators have been described. Drug delivery patches on the patient's chest can prevent electrode-skin contact and may block delivery of the electric discharge. In the United States, about 1 in 5 functioned over a 10-year period, mainly due to electrical or software problems. In summary, automated external defibrillators have a favourable risk-benefit balance, at least in trained hands. Specific training helps first-responders to act purposefully and without delay, and to implement the chain of survival until medical help arrives.
Authors:
-
Related Documents :
7720285 - Emergency intracardiac defibrillation for refractory ventricular fibrillation.
6196735 - The repetitive ventricular response: relationship to ventricular fibrillation threshold...
6724745 - Automated external defibrillation: laboratory evaluation.
8589875 - Elevated defibrillation threshold when right-sided venous access is used for nonthoraco...
22084195 - Effect of intracoronary delivery of autologous bone marrow mononuclear cells 2 to 3 wee...
12618725 - Feasibility of real-time echocardiographic evaluation during patient transport.
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Prescrire international     Volume:  19     ISSN:  1167-7422     ISO Abbreviation:  Prescrire Int     Publication Date:  2010 Jun 
Date Detail:
Created Date:  2010-08-26     Completed Date:  2010-09-09     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9439295     Medline TA:  Prescrire Int     Country:  France    
Other Details:
Languages:  eng     Pagination:  126-9     Citation Subset:  T    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Defibrillators* / adverse effects
Equipment Failure
Humans
Risk
Ventricular Fibrillation / mortality,  therapy*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Inhaled antimuscarinic drugs: cardiovascular toxicity.
Next Document:  INR self-monitoring and oral anticoagulants.