Document Detail


Automated drug dispensing system reduces medication errors in an intensive care setting.
MedLine Citation:
PMID:  20838333     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction.
DESIGN: Preintervention and postintervention study involving a control and an intervention medical intensive care unit.
SETTING: Two medical intensive care units in the same department of a 2,000-bed university hospital.
PATIENTS: Adult medical intensive care patients.
INTERVENTIONS: After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control.
MEASUREMENTS AND MAIN RESULTS: The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; p<.05); however, no significant difference was observed before automated dispensing system implementation (20.4% and 19.3%, respectively; not significant). Before-and-after comparisons in the study unit also showed a significantly reduced percentage of total opportunities for error (20.4% and 13.5%; p<.01). An analysis of detailed opportunities for error showed a significant impact of the automated dispensing system in reducing preparation errors (p<.05). Most errors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale.
CONCLUSIONS: The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.
Authors:
Claire Chapuis; Matthieu Roustit; Gaëlle Bal; Carole Schwebel; Pascal Pansu; Sandra David-Tchouda; Luc Foroni; Jean Calop; Jean-François Timsit; Benoît Allenet; Jean-Luc Bosson; Pierrick Bedouch
Related Documents :
15582783 - Doctors' responses to medical errors.
18198963 - How to prevent medication errors in long-term care: part 2.
8092903 - Academic surgical group practices at the dawn of health reform.
Publication Detail:
Type:  Journal Article; Randomized Controlled Trial; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Critical care medicine     Volume:  38     ISSN:  1530-0293     ISO Abbreviation:  Crit. Care Med.     Publication Date:  2010 Dec 
Date Detail:
Created Date:  2010-11-22     Completed Date:  2010-12-21     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0355501     Medline TA:  Crit Care Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2275-81     Citation Subset:  AIM; IM    
Affiliation:
Pharmacy Department, Grenoble University Hospital, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Automation
Drug Administration Schedule
Female
Hospitals, University
Humans
Intensive Care / standards,  trends
Intensive Care Units*
Intervention Studies
Male
Medical Order Entry Systems*
Medication Errors / prevention & control*,  statistics & numerical data
Medication Systems, Hospital / organization & administration*
Middle Aged
Pharmaceutical Preparations / administration & dosage
Program Evaluation
Questionnaires
Reference Values
Total Quality Management
Chemical
Reg. No./Substance:
0/Pharmaceutical Preparations

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Delirium duration and mortality in lightly sedated, mechanically ventilated intensive care patients.
Next Document:  Muscarinic receptor antagonist therapy improves acute pulmonary dysfunction after smoke inhalation i...