Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis.
MedLine Citation:
PMID:  22914573     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE:: The measurement of blood pressure in atrial fibrillation is considered as difficult and uncertain, and current guidelines recommend the use of the auscultatory method. The accuracy of automated blood pressure monitors in atrial fibrillation remains controversial. METHOD:: A systematic review and meta-analysis was performed of studies comparing automated (oscillometric or automated Korotkov) versus manual auscultatory blood pressure measurements (mercury or aneroid sphygmomanometer) in patients with sustained atrial fibrillation. RESULTS:: Twelve validations were analyzed (566 patients; five home, three ambulatory and three office devices). Pooled correlation coefficients between automated and manual blood pressure measurements were stronger for SBP than DBP (r = 0.89 versus 0.76, P < 0.001). Automated measurements were higher than manual measurements [pooled average SBP difference 0.5 mmHg, 95% confidence interval (CI) -0.9, 1.9; DBP 2.5 mmHg, 95%CI -0.6, 5.7). The mean difference was within 5 mmHg in six and four (SBP and DBP, respectively) of six validations. The SD of mean difference was within 8 mmHg in two and three (SBP and DBP, respectively) of four validations. The proportion of absolute automated-manual differences within 5 mmHg was at least 65% in four and two (SBP and DBP, respectively) of eight validations. Three studies showed no impact of heart rate on the automated-manual blood pressure differences. CONCLUSION:: There is limited evidence and significant heterogeneity in the studies that validated automated blood pressure monitors in atrial fibrillation. These monitors appear to be accurate in measuring SBP but not DBP. Given that atrial fibrillation is common in the elderly, in whom systolic hypertension is more common and important than diastolic hypertension, automated monitors appear to be appropriate for self-home but not for office measurement.
Authors:
George S Stergiou; Anastasios Kollias; Antonios Destounis; Dimitrios Tzamouranis
Related Documents :
3828893 - Cardiovascular actions of amrinone in anesthetized open-chest pigs with an acute mild s...
22421373 - Porcine model of ruptured abdominal aortic aneurysm repair.
17170623 - Left ventricular hypertrophy in patients with renal artery stenosis.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-8-21
Journal Detail:
Title:  Journal of hypertension     Volume:  -     ISSN:  1473-5598     ISO Abbreviation:  J. Hypertens.     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-8-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8306882     Medline TA:  J Hypertens     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Hypertension Center, Third University Department of Medicine, Sotiria Hospital, Athens, Greece.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Morphological assessment of renal arteries after radiofrequency catheter-based sympathetic denervati...
Next Document:  Desymmetrisation of aromatic diamines and synthesis of non-symmetrical thiourea derivatives by click...