Auscultatory and oscillometric methods of ambulatory blood pressure monitoring, advantages and limits: a technical point of view.
MedLine Citation:
PMID:  10226223     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Two methods of indirect blood pressure (BP) measurement are currently used for ambulatory blood pressure measurement (ABPM): the auscultatory and oscillometric methods. The auscultatory method is based on the detection of Korotkoff sounds issued from the acoustic transudcer signal. Its main advantages are (1) similarities with usual clinical measurement of BP; and (2) accurate detection of systolic and diastolic pressures on the appearance and disappearance of sounds. The main disadvantages of this method are (1) artefacts due to movements; and (2) difficulties in signal analysis due to physiological variations of the Korotkoff sound patterns or poor signals. Difficulties can be overcome by appropriate signal processing (K2 recognition), noise rejection and/or ECG gating. This may allow relatively accurate BP measurement during mild exercise. With the oscillometric method, air volume variations in the cuff are detected during deflation. The maximum oscillation is related to the mean arterial pressure. The systolic and diastolic BP are determined by an algorithmic interpretation of the shape of oscillometric amplitudes as well as the heart rate. The main advantages are (1) possibility of BP measurement when the Korotkoff signal is poor; (2) measurement of the mean arterial BP; and (3) no need of a microphonic sensor. The main disadvantages are (1) some oscillometric curves are difficult to read accurately; (2) oscillometry is very sensitive to movements due to the bandwidth of the signals, so the arm must be immobile; and (3) the accuracy of the systolic and diastolic BP depends on the algorithm used. These two methods are complementary and should ideally be associated in the same device.
Authors:
Bonnafoux
Related Documents :
8790923 - Is hypertension changing? blood pressure development in cohorts of 50-year-old men betw...
1425143 - The relationship between the development and progression of microalbuminuria and arteri...
12142123 - Echocardiographic quantification of left ventricular asynchrony predicts an acute hemod...
Publication Detail:
Type:  JOURNAL ARTICLE    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  1     ISSN:  1473-5725     ISO Abbreviation:  Blood Press Monit     Publication Date:  1996 Jun 
Date Detail:
Created Date:  1999-05-04     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  181-185     Citation Subset:  -    
Affiliation:
R & D Department, NOVACOR, Rueil-Malmaison, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Devices for measuring 24 h blood pressure.
Next Document:  A comparison between the oscillometric and the auscultatory method for ambulatory 24 h blood pressur...