Assessment of a technique to determine the mechanical properties of coronary arteries using mock arteries.
MedLine Citation:
PMID:  15382837     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Heart disease is the leading cause of death in the western world, and percutaneous transluminal coronary angioplasty (PTCA) and stent deployment are standard procedures used to reopen and/or stabilize blocked coronary arteries. Despite considerable improvements in these techniques, restenosis is still a long term problem, with patients requiring repeated procedures. Hence, further investigation of the mechanisms that contribute to arterial wall remodelling may help to improve the success of percutaneous coronary interventions (PCI). The aim of this study was to assess a measurement technique for its ability to determine the compliance of mock arteries using different balloon catheters during a standard angioplasty procedure. Pressure-volume (PV) curves were used to determine the combined mechanical response of the system, the balloon catheters and mock arteries in real time. The validity of subtracting the system compliance from the PV curves containing the system, balloon and/or mock artery was assessed using two-independent measurement techniques to determine the balloon inflation volume. Eighteen balloon catheters from four different manufactures were inflated inside three mock arteries with differing compliances (high, medium, low) and the resulting PV curves were recorded. The compliances of the three mock arteries were then determined from the PV curves. The results were compared to reference values of the three mock arteries, which were determined from one of the independent mechanical tests. Corrections for each balloon catheter type and each individual balloon catheter were studied. A correlation coefficient of 0.99 between the two-independent volume measurement techniques confirmed the validity of subtracting the system compliance. The compliance values for the high, medium and low compliant mock arteries, obtained by using the different balloon catheters, varied between 4 and 12, 3 and 9 and, 2 and 5 (microl/bar) mm(-1), respectively. Standard deviation varied from 0.1 up to 2.1 (microl/bar) mm(-1). This was equivalent to a mean variation factor (root mean square/mean) of 29%, which reduced to 12% with correction. The system was always able to detect differences between mock arteries in spite of the large variation with different balloon catheters. The study has shown that it is possible to determine compliances of different mock arteries using different balloon catheters. However, the determined compliances needed to be corrected for different mechanical properties of the balloons used.
Authors:
Tom Olbrich; Alan Murray
Related Documents :
6224917 - Deflation of metrizamide-filled balloon used to occlude a carotid-cavernous fistula. ca...
16447007 - Percutaneous transhepatic use of a cutting balloon in the treatment of a benign common ...
2590937 - Percutaneous transluminal coronary angioplasty using a combined "balloon-on-a-wire" sys...
2032907 - Treatment of posttraumatic carinal stenosis by balloon dilation during thoracotomy in a...
16322917 - Malpractice in invasive cardiology: is angiography of abdominal aorta or subclavian art...
15541967 - Modified ross procedure using a conduit with a synthetic valve.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Physiological measurement     Volume:  25     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  2004 Aug 
Date Detail:
Created Date:  2004-09-22     Completed Date:  2004-11-16     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  England    
Other Details:
Languages:  eng     Pagination:  997-1011     Citation Subset:  IM    
Affiliation:
Regional Medical Physics Department, Freeman Hospital, University of Newcastle upon Tyne, Newcastle upon Tyne, UK. tom.olbrich@nuth.northy.nhs.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Transluminal, Percutaneous Coronary*
Biomechanics
Coronary Restenosis / physiopathology
Coronary Stenosis / physiopathology*,  therapy
Coronary Vessels / physiology*
Humans
Models, Biological*
Pressure

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  How to check steady-state condition from cardiovascular time series.
Next Document:  Determining the effects of memory and action potential duration alternans on cardiac restitution usi...