Application of the optically stimulated luminescence (OSL) technique for mouse dosimetry in micro-CT imaging.
MedLine Citation:
PMID:  24320529     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Purpose: Micro-CT is considered to be a powerful tool to investigate various models of disease on anesthetized animals. In longitudinal studies, the radiation dose delivered by the micro-CT to the same animal is a major concern as it could potentially induce spurious effects in experimental results. Optically stimulated luminescence dosimeters (OSLDs) are a relatively new kind of detector used in radiation dosimetry for medical applications. The aim of this work was to assess the dose delivered by the CT component of a micro-SPECT (single-photon emission computed tomography)∕CT camera during a typical whole-body mouse study, using commercially available OSLDs based on Al2O3:C crystals.Methods: CTDI (computed tomography dose index) was measured in micro-CT with a properly calibrated pencil ionization chamber using a rat-like phantom (60 mm in diameter) and a mouse-like phantom (30 mm in diameter). OSLDs were checked for reproducibility and linearity in the range of doses delivered by the micro-CT. Dose measurements obtained with OSLDs were compared to those of the ionization chamber to correct for the radiation quality dependence of OSLDs in the low-kV range. Doses to tissue were then investigated in phantoms and cadavers. A 30 mm diameter phantom, specifically designed to insert OSLDs, was used to assess radiation dose over a typical whole-body mouse imaging study. Eighteen healthy female BALB∕c mice weighing 27.1 ± 0.8 g (1 SD) were euthanized for small animal measurements. OLSDs were placed externally or implanted internally in nine different locations by an experienced animal technician. Five commonly used micro-CT protocols were investigated.Results: CTDI measurements were between 78.0 ± 2.1 and 110.7 ± 3.0 mGy for the rat-like phantom and between 169.3 ± 4.6 and 203.6 ± 5.5 mGy for the mouse-like phantom. On average, the displayed CTDI at the operator console was underestimated by 1.19 for the rat-like phantom and 2.36 for the mouse-like phantom. OSLDs exhibited a reproducibility of 2.4% and good linearity was found between 60 and 450 mGy. The energy scaling factor was calculated to be between 1.80 ± 0.16 and 1.86 ± 0.16, depending on protocol used. In phantoms, mean doses to tissue over a whole-body CT examination were ranging from 186.4 ± 7.6 to 234.9 ± 7.1 mGy. In mice, mean doses to tissue in the mouse trunk (thorax, abdomen, pelvis, and flanks) were between 213.0 ± 17.0 and 251.2 ± 13.4 mGy. Skin doses (3 OSLDs) were much higher with average doses between 350.6 ± 25.3 and 432.5 ± 34.1 mGy. The dose delivered during a topogram was found to be below 10 mGy. Use of the multimouse bed of the system gave a significantly 20%-40% lower dose per animal (p < 0.05).Conclusions: Absorbed doses in micro-CT were found to be relatively high. In micro-SPECT∕CT imaging, the micro-CT unit is mainly used to produce a localization frame. As a result, users should pay attention to adjustable CT parameters so as to minimize the radiation dose and avoid any adverse radiation effects which may interfere with biological parameters studied.
Authors:
Jean-Marc Vrigneaud; Alan Courteau; Julien Ranouil; Loïc Morgand; Olivier Raguin; Paul Walker; Alexandra Oudot; Bertrand Collin; François Brunotte
Related Documents :
15998329 - High resolution b-scan ultrasound of hypertrophic scars.
24915119 - Presence of brown adipose tissue in an adolescent with severe primary hypothyroidism.
9101329 - A geometric snake model for segmentation of medical imagery.
25252279 - Spectral ct modeling and reconstruction with hybrid detectors in dynamic-threshold-base...
24974309 - The fundamentals of fetal magnetic resonance imaging: part 2.
23653219 - Recurrent skeletal extra-axial chordoma confirmed with brachyury: imaging features and ...
4001369 - Ecg-synchronized cardiac mr imaging: method and evaluation.
7672769 - Fibrolamellar variant of hepatocellular carcinoma--report of a chinese patient.
21228949 - Acinar cell cystadenoma (acinar cystic transformation) of the pancreas: the radiologic-...
Publication Detail:
Type:  JOURNAL ARTICLE    
Journal Detail:
Title:  Medical physics     Volume:  40     ISSN:  0094-2405     ISO Abbreviation:  Med Phys     Publication Date:  2013 Dec 
Date Detail:
Created Date:  2013-12-10     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  -    
Other Details:
Languages:  ENG     Pagination:  122102     Citation Subset:  -    
Affiliation:
Department of Nuclear Medicine, Centre Georges-François Leclerc, 1 rue Professeur Marion, Dijon 21079 Cedex, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Quality assurance of asymmetric jaw alignment using 2D diode array.
Next Document:  Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy...