Document Detail


Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration.
MedLine Citation:
PMID:  2752085     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Continuous deformation and entry flow of single blood granulocytes into small caliber micropipets at various suction pressures have been studied to determine an apparent viscosity for the cell contents and to estimate the extent that dissipation in a cortical layer adjacent to the cell surface contributes to the total viscous flow resistance. Experiments were carried out with a wide range of pipet sizes (2.0-7.5 microns) and suction pressures (10(2)-10(4) dyn/cm2) to examine the details of the entry flow. The results show that the outer cortex of the cell maintains a small persistent tension of approximately 0.035 dyn/cm. The tension creates a threshold pressure below which the cell will not enter the pipet. The superficial plasma membrane of these cells appears to establish an upper limit to surface dilation which is reached after microscopic "ruffles" and "folds" have been pulled smooth. With aspiration of cells by small pipets (less than 2.7 microns), the limit to surface expansion was derived from the maximal extension of the cell into the pipet; final areas were measured to be 2.1 to 2.2 times the area of the initial spherical shape. For suctions in excess of a threshold, the response to constant pressure was continuous flow in proportion to excess pressure above the threshold with only a small nonlinearity over time until the cell completely entered the pipet (for pipet calibers greater than 2.7 microns). With a theoretical model introduced in a companion paper, (Yeung, A., and E. Evans., 1989, Biophys. J. 56:139-149) the entry flow response versus pipet size and suction pressure was analyzed to estimate the apparent viscosity of the cell interior and the ratio of cortical flow resistance to flow resistance from the cell interior. The apparent viscosity was found to depend strongly on temperature with values on the order of 2 x 10(3) poise at 23 degrees C, lower values of 1 x 10(3) poise at 37 degrees C, but extremely large values in excess of 10(4) poise below 10 degrees C. Because of scatter in cell response, it was not possible to accurately establish the characteristic ratio for flow resistance in the cortex to that inside the cell; however, the data showed that the cortex does not contribute significantly to the total flow resistance.
Authors:
E Evans; A Yeung
Related Documents :
6658395 - Cultured human cells with a high content of metallothionein show resistance against gol...
2563655 - Analysis of structural features of dihydropyridine analogs needed to reverse multidrug ...
16542215 - Role of abcg2 as a biomarker for predicting resistance to cpt-11/sn-38 in lung cancer.
20531415 - Recovery of phospho-erk activity allows melanoma cells to escape from braf inhibitor th...
21945075 - Rac1 gtpase-deficient mouse lens exhibits defects in shape, suture formation, fiber cel...
7526745 - Development of nucleolar apparatus in the chick primitive erythroid cells.
Publication Detail:
Type:  In Vitro; Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Biophysical journal     Volume:  56     ISSN:  0006-3495     ISO Abbreviation:  Biophys. J.     Publication Date:  1989 Jul 
Date Detail:
Created Date:  1989-08-29     Completed Date:  1989-08-29     Revised Date:  2009-11-18    
Medline Journal Info:
Nlm Unique ID:  0370626     Medline TA:  Biophys J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  151-60     Citation Subset:  IM    
Affiliation:
Department of Pathology, University of British Columbia, Vancouver, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Granulocytes / cytology,  physiology*
Humans
Models, Theoretical
Pressure
Video Recording
Viscosity
Grant Support
ID/Acronym/Agency:
GM38331/GM/NIGMS NIH HHS
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Resolvability of free energy changes for oxygen binding and subunit association by human hemoglobin.
Next Document:  Intermediates in membrane fusion and bilayer/nonbilayer phase transitions imaged by time-resolved cr...