Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose.
MedLine Citation:
PMID:  22225284     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Purpose: X-ray scatter is a major detriment to image quality in cone-beam CT (CBCT). Existing geometries exhibit strong differences in scatter susceptibility with more compact geometries, e.g., dental or musculoskeletal, benefiting from antiscatter grids, whereas in more extended geometries, e.g., IGRT, grid use carries tradeoffs in image quality per unit dose. This work assesses the tradeoffs in dose and image quality for grids applied in the context of low-dose CBCT on a mobile C-arm for image-guided surgery.Methods: Studies were performed on a mobile C-arm equipped with a flat-panel detector for high-quality CBCT. Antiscatter grids of grid ratio (GR) 6:1-12:1, 40 lp∕cm, were tested in "body" surgery, i.e., spine, using protocols for bone and soft-tissue visibility in the thoracic and abdominal spine. Studies focused on grid orientation, CT number accuracy, image noise, and contrast-to-noise ratio (CNR) in quantitative phantoms at constant dose.Results: There was no effect of grid orientation on possible gridline artifacts, given accurate angle-dependent gain calibration. Incorrect calibration was found to result in gridline shadows in the projection data that imparted high-frequency artifacts in 3D reconstructions. Increasing GR reduced errors in CT number from 31%, thorax, and 37%, abdomen, for gridless operation to 2% and 10%, respectively, with a 12:1 grid, while image noise increased by up to 70%. The CNR of high-contrast objects was largely unaffected by grids, but low-contrast soft-tissues suffered reduction in CNR, 2%-65%, across the investigated GR at constant dose.Conclusions: While grids improved CT number accuracy, soft-tissue CNR was reduced due to attenuation of primary radiation. CNR could be restored by increasing dose by factors of ∼1.6-2.5 depending on GR, e.g., increase from 4.6 mGy for the thorax and 12.5 mGy for the abdomen without antiscatter grids to approximately 12 mGy and 30 mGy, respectively, with a high-GR grid. However, increasing the dose poses a significant impediment to repeat intraoperative CBCT and can cause the cumulative intraoperative dose to exceed that of a single diagnostic CT scan. This places the mobile C-arm in the category of extended CBCT geometries with sufficient air gap for which the tradeoffs between CNR and dose typically do not favor incorporation of an antiscatter grid.
Authors:
S Schafer; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; J H Siewerdsen
Related Documents :
9429734 - Current status of imaging procedures in the diagnosis, prognosis and monitoring of oste...
1790384 - Mr imaging of poststenotic flow phenomena: experimental studies.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Medical physics     Volume:  39     ISSN:  0094-2405     ISO Abbreviation:  Med Phys     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-01-09     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  153     Citation Subset:  IM    
Affiliation:
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  TomoTherapy MLC verification using exit detector data.
Next Document:  Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an indepen...