| Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil. | |
| | |
MedLine Citation:
|
PMID: 18695206 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
The purpose of the study was to determine the accuracy of half-Fourier single-shot rapid acquisition with relaxation enhancement high-spatial-resolution magnetic resonance (MR) imaging performed with a microscopy coil in the diagnosis of narrow anterior chamber angle in patients with glaucoma. Slit-lamp biomicroscopy served as the reference standard. The institutional review board approved this study, and written informed consent was obtained from the 20 recruited patients. There was excellent agreement between MR gonioscopy and slit-lamp biomicroscopy in the classification of anterior chamber angles as narrow or open (kappa = 0.89 [95% confidence interval: 0.69, 1.10]). MR gonioscopy has substantial potential as a technique used to evaluate glaucoma. |
| | |
Authors:
|
Keizo Tanitame; Ko Sasaki; Takashi Sone; Shinji Uyama; Masumi Sumida; Toshio Ichiki; Katsuhide Ito |
Related Documents
:
|
9111666 - High-resolution surface-coil mr of cortical lesions in medically refractory epilepsy: a... 2628686 - A comparison of three radiofrequency coils for nmr studies of conductive samples. 18230486 - Reversible intraframe compression of medical images. 16874286 - New method of evaluating edge-preserving adaptive filters for computed tomography (ct):... 17494666 - Multimodality imaging of cortical and white matter abnormalities in sturge-weber syndrome. 11044056 - Ovarian carcinoma in patients with endometriosis: mr imaging findings. |
Publication Detail:
|
Type: Journal Article Date: 2008-08-11 |
Journal Detail:
|
Title: Radiology Volume: 249 ISSN: 1527-1315 ISO Abbreviation: Radiology Publication Date: 2008 Oct |
Date Detail:
|
Created Date: 2008-09-17 Completed Date: 2008-10-15 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0401260 Medline TA: Radiology Country: United States |
Other Details:
|
Languages: eng Pagination: 294-300 Citation Subset: AIM; IM |
Copyright Information:
|
(c) RSNA, 2008. |
Affiliation:
|
Department of Radiology, Hiroshima General Hospital of West Japan Railway Company, 3-1-36 Futabanosato, Higashiku, Hiroshima 732-0057, Japan. tntrad@ms1.megaegg.ne.jp |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adult Aged Aged, 80 and over Anterior Chamber / pathology* Diagnostic Techniques, Ophthalmological Female Fourier Analysis Glaucoma / pathology* Gonioscopy / methods* Humans Magnetic Resonance Imaging / methods* Male Middle Aged |