Document Detail


Anatomical parameters of subaxial percutaneous transfacet screw fixation based on the analysis of 50 computed tomography scans.
MedLine Citation:
PMID:  22519926     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Object Cervical transfacet screw placement has been described in the literature. Although the technique shows promise for percutaneous application, parameters for screw placement have not been well delineated. This study used reconstructed CT scans with imaging software to assess the feasibility of percutaneous transfacet screw placement, analyzing potential entry angles, transfacet lengths, and sex differences at each subaxial level. Methods Fifty consecutive cervical CT scans (obtained in 26 males and 24 females [mean age 41.5 years]) were reformatted using OsiriX software, and transfacet lengths, entry angles, and potential occipital clearance were analyzed at all subaxial levels. Statistical analyses were used to determine the differences, if any, between transfacet lengths, entry angle, and occipital clearance across individual cervical levels. Repeatability was quantified by calculating the intraclass correlation coefficient and Cohen kappa value. Results A total of 200 transfacet lengths and 200 entry angles in 50 patients were analyzed. The mean transfacet lengths were 17.9 ± 2.6, 17.6 ± 3.2, 16.3 ± 3.6, and 13.1 ± 2.2 mm at C3-4, C4-5, C5-6, and C6-7, respectively, with mean entry angles at 52.7° ± 7.8°, 56.5° ± 8.0°, 55.0° ± 8.8°, and 53.0° ± 8.7°, respectively. Analysis of variance revealed a significant difference between the mean transfacet lengths, while post hoc analysis revealed significantly larger transfacet lengths in the upper 2 cervical levels (C3-4 and C4-5) than in the lower 2 cervical levels (C5-6 and C6-7). Analysis of variance demonstrated no significant difference between the entry angles. Males had significantly larger transfacet lengths at C5-6 (17.4 vs 15.1 mm) and C6-7 (13.7 vs 12.4 mm) than females. The occiput would have blocked percutaneous screw placement in 86%, 78%, 54%, and 20% of the cases at C3-4, C4-5, C5-6, and C6-7, respectively. Transfacet lengths may accommodate longer screws in the upper cervical spine, but potential screw sizes decrease in the lower subaxial levels. A transfacet entry angle of approximately 50° or greater was associated with a higher incidence of occipital clearance. Additionally, the occiput may pose a significant obstruction to percutaneous transfacet fixation in upper subaxial levels. Interrater reliability was poor for screw angle and length measurements, but was satisfactory in intrarater analysis in 6 of 8 measurements. There was moderate to good agreement of occipital clearance in all but one measurement. Conclusions Cervical transfacet screw placement is possible from C-3 to C-7. Because occipital clearance can be difficult at C3-4 and C6-7, the use of curved or flexible instruments may be necessary to obtain the appropriate screw trajectory. Screw lengths varied with spinal level and the sex of the patient.
Authors:
Charles Milchteim; Warren D Yu; Anthony Ho; Joseph R O'Brien
Related Documents :
8735346 - Superior sagittal sinus thrombosis complicating maintenance treatment for acute lymphob...
2909126 - Adrenal hemorrhage and renal vein thrombosis in the newborn: mr imaging.
8615266 - Mr angiography for mapping potential central venous access sites in patients with advan...
7714596 - Meningiomas arising from the falcotentorial junction. clinical features, neuroimaging s...
2764816 - Lymphomatoid granulomatosis presenting as a progressive cervical cord lesion.
7612706 - Detection of lung nodules in digital chest radiographs using artificial neural networks...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-4-20
Journal Detail:
Title:  Journal of neurosurgery. Spine     Volume:  -     ISSN:  1547-5646     ISO Abbreviation:  -     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-4-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101223545     Medline TA:  J Neurosurg Spine     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Orthopaedic Surgery, George Washington University, Washington, DC.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Rapid and simple DNA extraction method for detection of enterotoxigenic Staphylococcus aureus direct...
Next Document:  Development of a large-animal model to measure dynamic cerebrospinal fluid pressure during spinal co...