Document Detail


Analytical Performance Evaluation of the Scanning Capillary Tube Viscometer for Measurement of Whole Blood Viscosity.
MedLine Citation:
PMID:  23099199     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Whole blood viscosity (WBV) is the resistance of blood flow in blood vessels. Increased WBV may be a cardiovascular risk factor. The proper screening of WBV can help the early detection of cardiovascular disease. We investigated the performance of a new scanning capillary tube viscometer (SCTV) for the measurement of WBV. METHODS: We evaluated the total precision of the SCTV for twenty days using three control viscosity materials, and the within-day precision with the whole blood samples of three different individuals. For the linearity evaluation, serial dilutions of a high concentration standard material were used. For the method comparison, the results of the SCTV method were compared to those of Brookfield rotating viscometer on 227 subjects. RESULTS: The SCTV had good within-run and total-run coefficient of variant (CV)s at low-, medium-, and high-concentration samples, at shear rates of 1 and 300s(-1). The within-day CVs with the three human blood samples were 6.3%, 3.7% and 3.8% at a shear rate of 1s(-1), and 3.2%, 3.0% and 4.1% at a shear rate of 300s(-1). The SCTV method showed an excellent linearity in the range of 84.9 to 558.2 milliPoise (mP) and 28.8 to 71.0 mP at shear rates of 1 and 300s(-1), respectively. For the comparison study, the SCTV and the rotating viscometer showed comparable results. CONCLUSIONS: The SCTV showed a stable analytical performance, and was comparable with the rotational viscometer. This new SCTV method can be used in the clinical laboratory for various needs.
Authors:
Hanah Kim; Young I Cho; Dong-Hwan Lee; Chul-Min Park; Hee-Won Moon; Mina Hur; Jin Q Kim; Yeo-Min Yun
Related Documents :
8207659 - Preliminary laboratory studies of inactivation of hiv-1 in needles and syringes contain...
19912209 - Very long half-life plasminogen activator inhibitor type 1 reduces bleeding in a mouse ...
12004929 - Measurement of blood and plasma coagulation time using free oscillating rheometry.
22762729 - Critical mechanical conditions around neovessels in carotid atherosclerotic plaque may ...
23102759 - Transfusion-associated microchimerism: the hybrid within.
947919 - A simple in vitro screening test for blood compatibility of materials.
7057279 - Subclinical effects of chronic increased lead absorption--a prospective study. part iv....
20096119 - The curvhdr method for gating flow cytometry samples.
15564919 - Nutrition of the intervertebral disc.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-22
Journal Detail:
Title:  Clinical biochemistry     Volume:  -     ISSN:  1873-2933     ISO Abbreviation:  Clin. Biochem.     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-26     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0133660     Medline TA:  Clin Biochem     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012. Published by Elsevier Inc.
Affiliation:
Department of Laboratory Medicine, Konkuk University School of Medicine, Seoul, Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effect of the menstrual cycle on serum diamine oxidase levels in healthy women.
Next Document:  Critical review and meta-analysis on the combination of heart-type fatty acid binding protein (H-FAB...