Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments.
MedLine Citation:
PMID:  18390326     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
There are concerns about workers repeatedly exposed to magnetic fields exceeding regulatory limits with respect to modern magnetic resonance imaging (MRI). As a result, there is need for an ambulatory magnetic field dosimeter capable of measuring these fields in and around an MRI scanner in order to evaluate the regulatory guidelines and determine any underlying exposure risks. This study presents results of tri-axial measurements using an ambulatory magnetic field dosimeter worn by workers during normal working shifts. We recorded and analyzed magnetic field exposures in and around 1.5 T, 2 T, and 4 T magnets during routine patient procedures. The data was integrated and averaged over time and evaluated against the latest exposure standards. Time-varying magnetic fields occur when individuals move through spatially non-uniform static magnetic fields or during gradient-pulsed magnetic fields or a combination of both. Our previous numerical analysis shows that at certain positions surrounding the MRI scanner ends, such fields may induce current densities and electric fields that may exceed the relevant EU, ICNIRP, and IEEE standards. A high-speed acquisition version of the dosimeter measured gradient- pulsed fields at positions accessible by MRI workers near the scanner ends, and the results were evaluated and compared against the numerical simulations and the standards. Our measurements confirm that workers can be exposed to magnetic fields exceeding the guidelines at positions near the gradient coil ends during clinical imaging and a high degree of correlation exists with the numerical results. While the time-weighted average magnetic field exposures in 1.5 T, 2 T, and 4 T were all within the regulatory limits during static magnetic field measurements, the peak limits for the head can be exceeded in some circumstances. This study presents a small number of routine shifts of data that provide indicative results of magnetic field exposure in real situations.
Authors:
Miguel A Fuentes; Adnan Trakic; Stephan J Wilson; Stuart Crozier
Related Documents :
14530976 - An mr-compatible device for the in situ assessment of isometric contractile performance...
8560396 - Effects of static magnetic fields on human periodontal fibroblasts in vitro.
19791956 - Magnetoresistance of tvo temperature sensor at t<1 k.
16700026 - Magnetic field correlation imaging.
14657426 - Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptom...
15388206 - Impact of ct scan in patients with first episode of suspected nephrolithiasis.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  IEEE transactions on bio-medical engineering     Volume:  55     ISSN:  0018-9294     ISO Abbreviation:  IEEE Trans Biomed Eng     Publication Date:  2008 Apr 
Date Detail:
Created Date:  2008-04-08     Completed Date:  2008-05-14     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0012737     Medline TA:  IEEE Trans Biomed Eng     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1355-64     Citation Subset:  IM    
Affiliation:
School of Information Technology, University of Queensland, St. Lucia, Australia. stuart@itee.uq.edu.au
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Australia
Body Burden*
Electromagnetic Fields*
Humans
Magnetic Resonance Imaging*
Maximum Allowable Concentration
Medical Staff*
Occupational Exposure / analysis*
Radiation Dosage
Radiation Monitoring / methods*
Radiation Protection / methods*
Relative Biological Effectiveness
Reproducibility of Results
Sensitivity and Specificity

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Robust unsupervised detection of action potentials with probabilistic models.
Next Document:  Designing the optical interface of a transcutaneous optical telemetry link.