Analysis of Suture Anchor Eyelet Position on Suture Failure Load.
MedLine Citation:
PMID:  21539579     Owner:  NLM     Status:  Publisher    
Objective: To compare mechanical performance of 2 orientations of the 5 mm Corkscrew(®) suture anchor with #5 Fiberwire(®) . Study Design: In vitro biomechanical study. Sample Population: Suture anchor-suture constructs (n=40). Methods: Acute and cyclic tensile loads were applied to suture threaded through eyelets of 40 anchors perpendicular to the long axis of the anchor. Eyelets were positioned so that the suture pull was in line with (anchor rotation angle of 0° [ARA 0]) or 90° (ARA 90) to the eyelet plane. Load at failure, stiffness, and cycles to failure were determined. Results: All constructs failed by suture breakage at the eyelet. Mean load at failure was significantly higher in the ARA 90 group (634±93 N) compared with the ARA 0 group (495±52 N; P=.0015). No significant difference was found between groups for mean number of cycles to failure (270±177 versus 178±109; P=.2166) and stiffness (50±4 versus 48±5 N/mm; P=.3141). Conclusions: The Corkscrew(®) 5 mm suture anchor with Fiberwire(®) suture fails via suture breakage at the eyelet under higher acute loads if the suture is loaded at an angle of 90° compared with 0° with respect to the plane of the eyelet.
Sevima A Aktay; Michael P Kowaleski
Related Documents :
8188199 - Savings in hospital bed-days related to treatment with clozapine.
18093099 - Migraine headache relief after percutaneous transcatheter closure of interatrial commun...
14616309 - Rivastigmine (exelon) for dementia in patients with parkinson's disease.
21539579 - Analysis of suture anchor eyelet position on suture failure load.
21157359 - Thermal suits as an alternative way to keep patients warm peri-operatively: a randomise...
10836289 - Remission of severe tardive dyskinesia in a schizophrenic patient treated with the atyp...
1611459 - Colonic anastomosis using the biofragmentable anastomotic ring and manual suture: a pro...
17341379 - Effects of mandibular odontogenic keratocyst surgery and removable partial prostheses o...
16434659 - Natural history of type a niemann-pick disease: possible endpoints for therapeutic trials.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-5-3
Journal Detail:
Title:  Veterinary surgery : VS     Volume:  -     ISSN:  1532-950X     ISO Abbreviation:  -     Publication Date:  2011 May 
Date Detail:
Created Date:  2011-5-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8113214     Medline TA:  Vet Surg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© Copyright 2011 by The American College of Veterinary Surgeons.
Orthopedic Research Laboratory, Department of Clinical Sciences, Cummings School of Veterinary Medicine at Tufts University, Foster Hospital for Small Animals, North Grafton, MA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  In vitro biomechanical comparison of dynamic compression plates with a rough contact surface and a p...
Next Document:  Surgical Treatment of Disk-Associated Wobbler Syndrome by a Distractable Vertebral Titanium Cage in ...