Abstract/OtherAbstract:
Measurement of left ventricular (LV) mechanical dyssynchrony from single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) allows optimization of cardiac resynchronization therapy in heart failure patients. We compared the discriminatory ability and reproducibility of a new software method, Corridor 4DM (4DM) to the established method, Emory Cardiac Toolbox (ECTb) in normals and heart failure patients. LV dyssynchrony was measured in 100 control (Group 1) and 100 patients with LVEF <35% (Group 2) using time to peak thickening with first harmonic, fourth harmonic, and volume curve methods with the 4DM software, and compared to ECTb. Of the 3 4DM methods, first harmonic had the best correlation with the ECTb (R = 0.88, slope = 1.00, P < 0.0001, bias = -0.18° [95% CI: -20°; 16°] for phase standard deviation; and similarly for histogram bandwidth, while volume curve analysis had the greatest variation. The intra and inter-observer reproducibility for 4DM time to peak thickening with first harmonic was very good (R = 0.99, P < 0.0001 and coefficient of variability 10% [95% CI 9.2-12%] for intra-observer, and R = 0.97, P < 0.0001, coefficient of variability 16% [15-17%] for inter-observer, respectively). Finally, in patients with LVEF <35%, the area under the curve on receiver operator characteristic analysis was 0.93 [95% CI: 0.89-0.97] to detect significant mechanical dyssynchrony (i.e. standard deviation ≥43°) using 4DM versus ECTb. The 4DM-software provides an accurate and reproducible alternative method of dyssynchrony analysis of SPECT MPI for evaluation and management of heart failure.
Authors:
Wael Aljaroudi; Wael A Jaber; Richard A Grimm; Thomas Marwick; Manuel D Cerqueira
Related Documents :
8924053 - Controversies concerning calcium antagonists.
22196883 - Left ventricular diastolic dysfunction as a predictor of rapid decline of residual rena...
14524573 - Biventricular support with the jarvik 2000 axial flow pump: a feasibility study.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-10-18
Journal Detail:
Title:  The international journal of cardiovascular imaging     Volume:  -     ISSN:  1875-8312     ISO Abbreviation:  -     Publication Date:  2011 Oct 
Date Detail:
Created Date:  2011-10-18     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100969716     Medline TA:  Int J Cardiovasc Imaging     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Division of Cardiovascular Medicine, Section of Imaging, Cleveland Clinic, Cleveland, OH, USA, aljarow@ccf.org.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector compu...
Next Document:  Superior Prognostic Importance of Perineural Invasion vs. Lymph Node Involvement After Curative Rese...