Age-based differences between mercury sphygmomanometer and pulse dynamic blood pressure measurements.
MedLine Citation:
PMID:  10212342     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Both the mercury sphygmomanometer and oscillometric measurement methods are widely in use for pediatric, adult, and geriatric patients. However, inherent differences between the methods of measurement may create varying degrees of sensitivity to age and potentially result in differences between measurements for these two techniques. DESIGN: Measurements of systolic and diastolic blood pressures in 154 subjects were obtained using the mercury sphygmomanometer and pulse dynamic oscillometric methods in accordance with the 1987 Association for the Advancement of Medical Instrumentation guidelines. Subjects were separated into three age groups and their data analyzed for differences between measurements for these two techniques. METHODS: Two qualified nurses derived systolic and diastolic blood pressures using phase I and phase IV Korotkoff sounds, respectively, during simultaneous monitoring with the pulse dynamic oscillometric method. RESULTS: Inter-nurse variabilities for measurement derived by mercury sphygmomanometer were 1.8 +/- 4.1 for systolic and 0.9 +/- 3.9for diastolic blood pressure. Mean differences (reference-device) of -5 +/- 5 mmHg (pulse dynamic value higher) for systolic and 1 +/- 5 mmHg (pulse dynamic value lower) for diastolic blood pressure between pulse dynamic and mercury sphygmomanometer values were found for all subjects. However, pulse dynamic systolic blood pressure was significantly higher than mercury sphygmomanometer systolic blood pressure for group 1 (n = 51, aged 11-22 years, mean difference -5.6 mmHg, P = 0.03). A similar trend was observed with group 2 (n = 51, aged 23-54 years, mean difference -4.3 mmHg, P = 0.06). We observedf no significant difference for systolic blood pressure with group 3 (n = 52, aged 55-85 years, mean difference -3.8 mmHg, P > 0.1). For all three groups we found no significant difference for diastolic blood pressure. CONCLUSION: The variation in the agreement of systolic blood pressure measurements can be attributed to the differing effects of age-dependent arterial changes on the measurement methods. The findings indicate that, although the pulse dynamic oscillometric method and mercury sphygmomanometer correlate well when patients of all ages were evaluated as a group, agreement between measurements of systolic blood pressure is dependent on age and the method of measurement employed.
Authors:
Brinton; Walls; Yajnik; Chio
Publication Detail:
Type:  JOURNAL ARTICLE    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  3     ISSN:  1473-5725     ISO Abbreviation:  Blood Press Monit     Publication Date:  1998 Apr 
Date Detail:
Created Date:  1999-04-22     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  125-129     Citation Subset:  -    
Affiliation:
Pulse Metric, Incorporated, San Diego, California, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Validation of pulse dynamic blood pressure measurement by auscultation.
Next Document:  What are the normal levels for ambulatory blood pressure measurement?