Document Detail


Adenosine Stress High-pitch 128-slice Dual Source Myocardial Computed Tomography Perfusion For Imaging Of Reversible Myocardial Ischemia: Comparison with Magnetic Resonance Imaging.
MedLine Citation:
PMID:  21862731     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: -Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis, however lacking information about hemodynamical significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac magnetic resonance imaging (CMR). METHODS AND RESULTS: -39 patients with intermediate-to-high coronary risk profile underwent adenosine stress 128-slice dual source CTP (128x0.6mm, 0.28s). Among those, 30 patients (64±10y, 6% females) also underwent adenosine stress CMR (1.5T). The 2-steps CTP protocol consisted of: 1) Adenosine stress-CTP using a high-pitch factor (3.4) ECG-synchronized spiral mode and 2) rest-CTP/coronary-CTA using either high-pitch (HR<63bpm) or prospective ECG-triggering (HR>63bpm). Results were compared to CMR and to invasive angiography (IA) in 25 patients. The performance of stress-CTP for detection of myocardial perfusion defects compared to CMR was: sens. 96%, spec. 88%, PPV 93%, NPV 94% (per vessel), and sens. 78%, spec. 87%, PPV 83%, NPV 84% (per segment). The accuracy of stress-CTP for imaging of reversible ischemia compared to CMR was: sens 95%, spec 96%, PPV 95%, NPV 96% (per vessel). In 25 patients who underwent IA, the accuracy of CTA for detection of stenosis >70% was (per segment): sens. 96%, spec. 88%, PPV 67%, NPV 98.9%. The accuracy improved from 84% to 95% after adding stress CTP to CTA. Radiation exposure of the entire stress/rest CT protocol was only 2.5mSv. CONCLUSIONS: -Adenosine-induced stress 128-slice dual source high-pitch myocardial CTP allows for simultaneously assessment of reversible myocardial ischemia and coronary stenosis with good diagnostic accuracy as compared to CMR and IA, at a very low radiation exposure.
Authors:
Gudrun Feuchtner; Robert Goetti; André Plass; Monika Wieser; Hans Scheffel; Christophe Wyss; Paul Stolzmann; Olivio Donati; Johannes Schnabl; Volkmar Falk; Hatem Alkadhi; Sebastian Leschka; Ricardo C Cury
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-8-23
Journal Detail:
Title:  Circulation. Cardiovascular imaging     Volume:  -     ISSN:  1942-0080     ISO Abbreviation:  -     Publication Date:  2011 Aug 
Date Detail:
Created Date:  2011-8-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101479935     Medline TA:  Circ Cardiovasc Imaging     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
1 Univ. Hosp. Zurich, CH; Innsbruck Med. Univ., AT; Baptist Cardiac & Vasc. Instit., Miami, FL;
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical Breast Examination: Preliminary Results from a Cluster Randomized Controlled Trial in India...
Next Document:  Quality of Care and Outcomes in Women Hospitalized for Heart Failure.