Document Detail


Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting.
MedLine Citation:
PMID:  22892852     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVR(i)). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient's clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated.
Authors:
Glen Atlas; David Brealey; Sunil Dhar; Gerhard Dikta; Meryvn Singer
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-8-15
Journal Detail:
Title:  Journal of clinical monitoring and computing     Volume:  -     ISSN:  1573-2614     ISO Abbreviation:  J Clin Monit Comput     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-8-15     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9806357     Medline TA:  J Clin Monit Comput     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Anesthesiology, New Jersey Medical School, University of Medicine and Dentistry of New Jersey, Newark, NJ, 07102, USA, atlasgm@umdnj.edu.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Computational models for large-scale simulations of facilitated diffusion.
Next Document:  PI3-kinase and TGF-? in glomerular nephropathy: which comes first?