Adaptive brightness transfer functions in echocardiography. | |
MedLine Citation:
|
PMID: 15866415 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
Despite the clear advantages of echocardiography as a diagnostic tool, its images tend to be noisy and unclear. This paper presents an innovative algorithm, called ABTF (adaptive brightness transfer function), designed to optimally adjust the gray-levels used in echocardiography. The algorithm is aimed at aiding in visual tissue classification and texture-based visual tissue tracking in echocardiographic images. The ABTF method is based on fitting the cine-loop's gray-level histogram to a sum of three Gaussian functions, each of which relates to a different region within the image, the left ventricular cavity, the relatively dark regions within the cardiac muscle and the bright regions within the cardiac muscle. The procedure's feasibility has been supported by a test-set, including 23 echocardiographic cine-loops from 10 different patients. The resulting image quality appears to be superior to that of the original images, tending to show better contrast and a higher dynamic range of gray-levels within the cardiac muscle. According to two expert cardiologists, who have blindly ranked the image quality of each cine-loop on a scale from 1 to 10, where 10 corresponds to the highest possible image quality, the mean score of the original cine-loops is 7.1 +/- 1.1, while the mean score of the cine-loops to which ABTF has been applied is 8.0 +/- 1.2. |
Authors:
|
Gil Zwirn; Solange Akselrod |
Related Documents
:
|
8933065 - Echocardiographic measurements of cardiac dimensions and indices of cardiac function in... 17145405 - Evaluation of left ventricular function with cardiac magnetic resonance imaging using f... 20228325 - Segmental approach to imaging of congenital heart disease. 16455415 - Real-time 3-dimensional echocardiographic imaging of congenital heart disease using mat... 12652365 - The seated man: geometry acquisition and three-dimensional reconstruction. 17621215 - Reliability of a functional classification system in the monitoring of patients with id... |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Ultrasound in medicine & biology Volume: 31 ISSN: 0301-5629 ISO Abbreviation: Ultrasound Med Biol Publication Date: 2005 May |
Date Detail:
|
Created Date: 2005-05-03 Completed Date: 2005-10-13 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0410553 Medline TA: Ultrasound Med Biol Country: England |
Other Details:
|
Languages: eng Pagination: 649-61 Citation Subset: IM |
Affiliation:
|
The Abramson Center of Medical Physics, Sackler Faculty of Exact Sciences, Tel Aviv University, Ramat Aviv, Tel Aviv 69978, Israel. zwirn@zahav.net.il |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
MeSH Terms | |
Descriptor/Qualifier:
|
Algorithms Echocardiography / methods* Heart Ventricles / ultrasonography Humans Image Enhancement / methods* Mathematics Normal Distribution Probability |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: The effects of therapeutic ultrasound on heart rate variability: a placebo controlled trial.
Next Document: Effect of vessel curvature on Doppler derived velocity profiles and fluid flow.