Document Detail


Acute and one year follow-up results after vessel size adapted PTCA using intracoronary ultrasound.
MedLine Citation:
PMID:  9519320     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
AIMS: Recent randomized clinical trials have reported a reduction in restenosis with intracoronary stents and have suggested that this restenosis reduction is a result of the higher immediate luminal gain, in comparison to conventional percutaneous transluminal coronary angioplasty (PTCA). The hypothesis of this study is based on the assumption that PTCA results may be optimized by determining vessel dimensions before intervention, using intravascular ultrasound. This may lead to long-term PTCA results equivalent to PTCA and the additional placement of a stent. The purpose of this prospective non-randomized single-centre study was to evaluate (1) the safety and efficacy and (2) the long-term outcome of vessel-size adapted PTCA in patients with native coronary artery obstructions. METHODS AND RESULTS: From January 1995 to December 1995 the morphological dimensions of target lesions were determined in 144 patients with 152 lesions by intravascular ultrasound prior to conventional balloon angioplasty. Quantitative assessment of the vascular dimensions were assessed on-line and the diameter of the balloon catheter was adapted to the external elastic membrane diameter at the lesion site. Using this strategy, mean balloon diameter was 4.0 +/- 0.5 mm and mean pressure for complete balloon expansion was 7 +/- 2 atmospheres. Acute and one year follow-up results were obtained in all 144 patients. Acute events occurred in two patients (one death and one acute surgical revascularization). During one year follow-up, 16 patients (12%) had a clinical event including one cardiac death, two transmural myocardial infarctions, 10 repeat PTCAs within the target lesion and three elective coronary artery bypass grafts (CABG). In 75% (n:112) control angiography was performed and revealed an angiographic restenosis rate of 21% using the NHLBI criteria of a diameter stenosis > 50%. CONCLUSION: Intravascular ultrasound provides an accurate and precise description of vascular dimensions at the site of the stenotic lesion. The use of balloon diameters following these measurements appears to be (1) safe in the acute setting with a low number of in hospital events and (2) gives a low restenosis rate and number of clinical events at one year follow-up. These promising results warrant verification in larger-scale randomized trials.
Authors:
K K Haase; A Athanasiadis; H Mahrholdt; A Treusch; B Wullen; C Jaramillo; A Baumbach; W Voelker; C Meisner; K R Karsch
Publication Detail:
Type:  Clinical Trial; Journal Article    
Journal Detail:
Title:  European heart journal     Volume:  19     ISSN:  0195-668X     ISO Abbreviation:  Eur. Heart J.     Publication Date:  1998 Feb 
Date Detail:
Created Date:  1998-04-30     Completed Date:  1998-04-30     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  8006263     Medline TA:  Eur Heart J     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  263-72     Citation Subset:  IM    
Affiliation:
Medical Clinic III, University of Tuebingen, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Angioplasty, Transluminal, Percutaneous Coronary / methods*
Coronary Angiography
Coronary Disease / radiography,  therapy*,  ultrasonography
Coronary Vessels / ultrasonography*
Female
Follow-Up Studies
Humans
Male
Middle Aged
Prospective Studies
Time Factors
Ultrasonography, Interventional*
Comments/Corrections
Comment In:
Eur Heart J. 1998 Feb;19(2):196-8   [PMID:  9519309 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The persistence of hibernating myocardium after acute myocardial infarction.
Next Document:  Improvement in left ventricular ejection fraction and wall motion after successful recanalization of...