Acute and chronic pulse-width thresholds in solid versus porous tip electrodes.
MedLine Citation:
PMID:  6182535     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Sixty-one patients given programmable pacemakers at initial implantation have been followed for a mean of 18 months (3-42) with non-invasive measurements of myocardial pulse-width threshold. Fifty of the patients had CPI 0505/0522 (Microlith-P/Microthin-PI) pacemakers with either Cordis 322-462 8 mm2 ball tip (n=12), Cordis 322-620 17.5 mm2 (n=23), or CPI 4116 porous tip electrodes (stimulation area 7.5 mm2 and sensing area 50 mm2) (n=15). Eleven patients had Medtronic 5985 (Spectrax-SX) pacemakers with either Medtronic 6907-R 8 mm2 ring tip (n=7), 6907 11 mm2 (n=3) or 6917 myocardial electrodes (area 12 mm2) (n=1). At acute implant, the ball tip and porous tip electrodes had the lowest stimulation thresholds, but the differences were only statistically significant in comparison with the 17.5 mm2 electrode (p less than 0.01). Chronically there were no significant differences between the various electrodes (p greater than 0.1), but the ball tip electrode tended to give best long-term results, and the porous tip electrode the poorest. Thirty-eight of the 61 patients (62.3%) had chronic pulse-width thresholds of 0.1 ms or less at approximately equal to 5 V output, indicating that pulse-width programming is a useful way to conserve battery energy. However, at some stage of the study, six of the patients (9.8%) had a pulse-width threshold of 0.5 ms or more. Pulse width should therefore not be set too narrow in standard nonprogrammable pacemakers.
Authors:
K Breivik; O J Ohm; H Engedal
Related Documents :
6461235 - Primary sick sinus syndrome as an indication for chronic pacemaker therapy in young adu...
1138735 - Sinoatrial block. autonomic influences and clinical assessment.
9789695 - Comparison of adenosine effects on atrioventricular node reentry and atrioventricular r...
3630895 - Effects of intravenous sotalol in patients with atrioventricular accessory pathways.
1442855 - Microalbuminuria in patients with essential hypertension: effects of several antihypert...
15538065 - Mode of death from congestive heart failure: implications for clinical management.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  5     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1982 Sep 
Date Detail:
Created Date:  1982-12-18     Completed Date:  1982-12-18     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  650-7     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aged
Arrhythmias, Cardiac / etiology,  therapy*
Electrocardiography
Electrodes, Implanted*
Female
Heart Rate
Humans
Male
Middle Aged
Pacemaker, Artificial*
Prospective Studies

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pacing threshold interval with decreasing and increasing output.
Next Document:  Programmed chest-wall stimulation to evaluate the progress of A-V block after pacemaker insertion in...