Abstract/OtherAbstract:
|
The goal of this study is to develop a focal zone sharpening strategy that produces more precise lesions for pulsed cavitational ultrasound therapy, or histotripsy. Precise and well-confined lesions were produced by locally suppressing cavitation in the periphery of the treatment focus without affecting cavitation in the center. The local suppression of cavitation was achieved using cavitation nuclei preconditioning pulses to actively control cavitation in the periphery of the focus. A 1-MHz 513-element therapeutic array was used to generate both the therapy and the nuclei preconditioning pulses. For therapy, 10-cycle bursts at 100-Hz pulse repetition frequency with P-/P+ pressure of 21/76 MPa were delivered to the geometric focus of the therapeutic array. For nuclei preconditioning, a different pulse was delivered to an annular region immediately surrounding the focus before each therapy pulse. A parametric study on the effective pressure, pulse duration, and delivery time of the preconditioning pulse was conducted in red blood cell-gel phantoms, where cavitational damage was indicated by the color change resulting from local cell lysis. Results showed that a short-duration (20 μs) preconditioning pulse at a medium pressure (P-/P+ pressure of 7.2/13.6 MPa) delivered shortly before (30 μs) the therapy pulse substantially suppressed the peripheral damage by 77 ± 13% while complete fractionation in the focal center was maintained. High-speed imaging of the bubble cloud showed a substantial decrease in the maximum width of the bubble cloud by 48 ± 24% using focal zone sharpening. Experiments in ex vivo livers confirmed that highly confined lesions were produced in real tissues as well as in the phantoms. This study demonstrated the feasibility of active focal zone sharpening using cavitation nuclei preconditioning, allowing for increased treatment precision compared with the natural focal width of the therapy transducer. |
| | |
Authors:
|
Tzu-Yin Wang; Zhen Xu; Timothy Hall; J Fowlkes; William Roberts; Charles Cain |
Related Documents
:
|
18269646 - Manometric study of the lower esophageal sphincter and esophagus in subtotal gastrectom... 7129816 - Biliary pressure measurement: an aid in the management of patients on internal biliary ... 2378716 - Techniques in electromanometry of the upper esophageal sphincter. 4029556 - Developmental characteristics of the lower esophageal sphincter in the kitten. 23530946 - Effects of dorzolamide-timolol and brimonidine-timolol on retinal vascular autoregulati... 2657626 - Adult respiratory distress syndrome in full-term newborns. |
Publication Detail:
|
Type: Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't |
Journal Detail:
|
Title: IEEE transactions on ultrasonics, ferroelectrics, and frequency control Volume: 58 ISSN: 1525-8955 ISO Abbreviation: IEEE Trans Ultrason Ferroelectr Freq Control Publication Date: 2011 Feb |
Date Detail:
|
Created Date: 2011-02-23 Completed Date: 2011-06-09 Revised Date: 2012-10-09 |
Medline Journal Info:
|
Nlm Unique ID: 9882735 Medline TA: IEEE Trans Ultrason Ferroelectr Freq Control Country: United States |
Other Details:
|
Languages: eng Pagination: 305-15 Citation Subset: IM |
Affiliation:
|
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA. tzuyin@umich.edu |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Ablation Techniques
/
instrumentation,
methods* Analysis of Variance Animals Dogs Equipment Design Erythrocytes / ultrasonography Histological Techniques Liver / pathology, ultrasonography Phantoms, Imaging Photography Ultrasonic Therapy / instrumentation, methods* |
| Grant Support | |
ID/Acronym/Agency:
|
R01 CA134579/CA/NCI NIH HHS; R01 CA134579-03/CA/NCI NIH HHS; R01 CA134579-05/CA/NCI NIH HHS; R01 DK087871-01/DK/NIDDK NIH HHS; R01 EB008998/EB/NIBIB NIH HHS; R01 EB008998/EB/NIBIB NIH HHS; R01 EB008998-03/EB/NIBIB NIH HHS; R01 HL077629/HL/NHLBI NIH HHS; S10RR022425/RR/NCRR NIH HHS |
| Comments/Corrections | |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Off-axis scattering of an ultrasound bessel beam by a sphere.
Next Document: Optoacoustic methods for frequency calibration of ultrasonic sensors.