Document Detail


Accuracy of the ultrasonic cardiac output monitor in healthy term neonates during postnatal circulatory adaptation.
MedLine Citation:
PMID:  21933558     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
BACKGROUND: Echocardiography is regarded as a gold standard for measuring hemodynamic values. The ultrasonic cardiac output monitor (USCOM) is a new method for measuring hemodynamics and could provide non-invasive point of care guidance. So far, there are no published USCOM reference values for neonates, nor has USCOM's accuracy been established in this population. We aimed to determine the accuracy and clinical utility of the USCOM in healthy neonates relative to published echocardiographic data, to establish normal hemodynamic parameters that it measures, and to assess the possible role of USCOM as an alternative to echocardiography as a trend monitor.
METHODS: Right and left heart hemodynamics of 90 normal neonates were measured during circulatory adaptation over the first three days of life using the USCOM and automated oscillotonometry.
RESULTS: Heart rate showed a significant decline from days one to three, from 126 to 120 (P < 0.001). Systolic, diastolic and mean arterial pressures all increased significantly from 66 to 71 mmHg, 33 to 38 mmHg and 44 to 49 mmHg, respectively (P < 0.001 in each case). Right ventricular cardiac index (RV-CI) showed no change with a mean of 5.07 L×min(-1)×m(-2). Left ventricular cardiac index (LV-CI) declined from 3.43 to 3.00 L×min(-1)×m(-2) (P < 0.001). RV-CI exceeded LV-CI on all three days by a mean of 61%. The systemic vascular resistance index (SVRI), based on LV-CI, increased significantly over the three days from 1083 to 1403 dyne×sec×cm(-5)×m(2) (P < 0.001).
CONCLUSIONS: Normal neonatal hemodynamic values, as indicated by USCOM, were established. LV-CI measurement showed excellent agreement with published echocardiographic studies. RV-CI was constant and exceeded LV-CI for all three days of this study. It may be falsely high due to flow velocity measurement errors arising from the pulmonary branch arteries, and may represent a limitation of the USCOM method. The progressive rise of arterial pressure and SVRI despite a declining LV-CI may indicate functional closure of the ductus arteriosus, with the greatest change occurring within the first 24 hours. Evidence of closure of the foramen ovale was not observed.
Authors:
Shao-Ru He; Cheng Zhang; Yu-Mei Liu; Yun-Xia Sun; Jian Zhuang; Ji-Mei Chen; Veronica M Madigan; Brendan E Smith; Xin Sun
Related Documents :
9073008 - Cardiovascular consequences of fibreoptic bronchoscopy.
24771058 - Control of blood pressure in hypertensive neurological emergencies.
20217118 - Tissue oxygenation measured with near-infrared spectroscopy during normobaric and hyper...
18250118 - Impaired autoregulation in preterm infants identified by using spatially resolved spect...
2347798 - Effects of various concentrations of o2 and umbilical cord occlusion on fetal breathing...
1315818 - Arginine vasopressin response to hypertonicity in hypertension studied by arginine vaso...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Chinese medical journal     Volume:  124     ISSN:  0366-6999     ISO Abbreviation:  Chin. Med. J.     Publication Date:  2011 Aug 
Date Detail:
Created Date:  2011-09-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7513795     Medline TA:  Chin Med J (Engl)     Country:  China    
Other Details:
Languages:  eng     Pagination:  2284-9     Citation Subset:  IM    
Affiliation:
Department of Neonatology, Guangdong Academy of Medical Sciences/Guangdong General Hospital, Guangzhou, Guangdong 510080, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Erlotinib as a salvage treatment for patients with advanced non-small cell lung cancer after failure...
Next Document:  Preservation of the kidney with delayed diagnosis of traumatic pelvi-ureteric junction disruption se...