Document Detail


Accuracy of three-dimensional linear and angular estimates obtained with the Ariel Performance Analysis System.
MedLine Citation:
PMID:  7848077     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Computer-assisted video motion analysis is a method of evaluating human kinematics that offers promise both for research and for clinical application. This study determined the upper limits of accuracy and consistency of linear and angular measures obtained using the Ariel Performance Analysis System. Reference standards included a meter stick and a universal 360 degrees goniometer. Average mean error observed for reconstruction of absolute point estimates was found to be less than 3.5 mm. Mean error estimate for three-dimensional (3D) reconstruction of a linear standard was found to be 1.4 mm (SD 0.30). Average mean angular error observed for 3D reconstruction of goniometer settings 10 degrees to 170 degrees was found to be 0.26 degrees (mean SD 0.21). System users are cautioned that some increased error associated with software derivation of joint angles exists as angles approach 180 degrees, use of wide-angle lens accessories introduces a systematic field-dependent bias; and planar rotation introduces some (< 2 degrees) random error.
Authors:
P J Klein; J J DeHaven
Related Documents :
16904697 - The importance of subjectivity in perceptual errors on the emergence of indirect recipr...
8333517 - Revised equations for calculating co2 production from doubly labeled water in humans.
18514467 - Observations on the use of the avr-v6 relationship to recognize limb lead error.
15212217 - The importance of type ii error and falsifiability.
21552527 - From isotropic to anisotropic side chain representations: comparison of three models fo...
16933127 - A constitutive law for the failure behavior of medial collateral ligaments.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Archives of physical medicine and rehabilitation     Volume:  76     ISSN:  0003-9993     ISO Abbreviation:  Arch Phys Med Rehabil     Publication Date:  1995 Feb 
Date Detail:
Created Date:  1995-03-07     Completed Date:  1995-03-07     Revised Date:  2005-11-17    
Medline Journal Info:
Nlm Unique ID:  2985158R     Medline TA:  Arch Phys Med Rehabil     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  183-9     Citation Subset:  AIM; IM    
Affiliation:
Division of Rehabilitation Sciences, D'Youville College, Buffalo, NY 14201.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Biomechanics
Calibration
Humans
Movement*
Physical Therapy Modalities / instrumentation*
Reproducibility of Results

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Exercise effect of modified contralateral stabilization bar during one-legged isokinetic exercise.
Next Document:  Rheumatoid arthritis: new approaches for its evaluation and management.