Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients.
MedLine Citation:
PMID:  10708169     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To evaluate the accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. DESIGN: Prospective data collection. SETTING: Emergency department in a 2,000-bed inner city hospital. PATIENTS: Thirty-eight patients categorized into three groups according to their upper-arm circumference (group I: 18-25 cm; group II: 25.1-33 cm; and group III: 33.1-47.5 cm) were enrolled in the study protocol. INTERVENTIONS: In each patient, all three cuff sizes (Hewlett-Packard Cuff 40401 B, C, and D) were used to perform an oscillometric blood pressure measurement at least within 3 mins until ten to 20 measurements for each cuff size were achieved. Invasive mean arterial blood pressure measurement was done by cannulation of the contralateral radial artery with direct transduction of the systemic arterial pressure waveform. The corresponding invasive blood pressure value was obtained at the end of each oscillometric measurement. MEASUREMENT AND MAIN RESULTS: Overall, 1,494 pairs of simultaneous oscillometric and invasive blood pressure measurements were collected in 38 patients (group I, n = 5; group II, n = 23; and group III, n = 10) over a total time of 72.3 hrs. Mean arterial blood pressure ranged from 35 to 165 mm Hg. The overall discrepancy between oscillometric and invasive blood pressure measurement was -6.7+/-9.7 mm Hg (p<.0001), if the recommended cuff size according to the upper-arm circumference was used (539 measurements). Of all the blood pressure measurements, 26.4% (n = 395) had a discrepancy of > or =10 mm Hg and 34.2% (n = 512) exhibited a discrepancy of > or =20 mm Hg. No differences between invasive and noninvasive blood pressure measurements were noted in patients either with or without inotropic support (-6.6 + 7.2 vs. -8.6 + 6.8 mm Hg; not significant). CONCLUSION: The oscillometric blood pressure measurement significantly underestimates arterial blood pressure and exhibits a high number of measurements out of the clinically acceptable range. The relation between cuff size and upper-arm circumference contributes substantially to the inaccuracy of the oscillometric blood pressure measurement. Therefore, oscillometric blood pressure measurement does not achieve adequate accuracy in critically ill patients.
Authors:
A Bur; M M Hirschl; H Herkner; E Oschatz; J Kofler; C Woisetschläger; A N Laggner
Related Documents :
4018039 - Auscultatory measurement of arterial pressure during anaesthesia: a reassessment of kor...
8257249 - A review of common errors in the indirect measurement of blood pressure. sphygmomanometry.
23300969 - High altitude bird migration at temperate latitudes: a synoptic perspective on wind ass...
23832349 - Regulation of cytochrome c- and quinol oxidases, and piezotolerance of their activities...
54189 - Measuring blood pressure. training film to illustrate problems of intra- and inter-obse...
17617159 - Determination of reference arterial blood pressure values by indirect methods for kanga...
11081769 - Lack of association between polymorphisms of angiotensin ii receptor genes and response...
15531169 - Effects of experimentally induced plantar insensitivity on forces and pressures under t...
11230309 - Alterations in blood pressure and heart rate variability in transgenic rats with low br...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Critical care medicine     Volume:  28     ISSN:  0090-3493     ISO Abbreviation:  Crit. Care Med.     Publication Date:  2000 Feb 
Date Detail:
Created Date:  2000-03-16     Completed Date:  2000-03-16     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0355501     Medline TA:  Crit Care Med     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  371-6     Citation Subset:  AIM; IM    
Affiliation:
Department of Emergency Medicine, Vienna General Hospital, University Clinics, Austria.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aged
Aged, 80 and over
Anthropometry
Arm / anatomy & histology*
Bias (Epidemiology)
Blood Pressure Determination / instrumentation*,  methods
Critical Illness
Equipment Design
Equipment Failure
Female
Humans
Linear Models
Male
Middle Aged
Monitoring, Physiologic / instrumentation,  methods
Oscillometry / instrumentation*,  methods
Prospective Studies
Reproducibility of Results

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Evaluation of an antiseptic triple-lumen catheter in an intensive care unit.
Next Document:  Nosocomial endocarditis in the intensive care unit: an analysis of 22 cases.