Document Detail


Accuracy of non-invasive blood pressure monitoring in very preterm infants.
MedLine Citation:
PMID:  22392028     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE: Blood pressure (BP) monitoring is an essential procedure in intensive care. There is controversy about the reliability of non-invasive BP measurements in very preterm infants. This prospective trial compared non-invasive BP monitoring with BP monitoring via an umbilical arterial catheter (UAC) in this population. METHODS: Preterm infants born at less than 32 weeks gestation requiring a UAC for clinical management were eligible. Enrolled infants had up to three BP measurements on the right arm (RA) and right leg (RL) when in a resting state. UAC-BP measurements were noted immediately after the non-invasive BP was displayed on the monitor. Measurements were analysed in subgroups according to birth weight: no greater than 750 g, 751-1,000 g, above 1,000 g. Statistical analysis reports median, range, and Bland-Altman analysis. RESULTS: Sixty infants were included. Median (range) gestational age was 26.4 weeks (23.6, 31.2); birth weight 924 g (581, 1,518). A total of 1,865 measurements were performed (RA: 935, RL: 930). Mean difference (95% limits of agreement) for infants no greater than 750 g: RA 2.53 mmHg (-11.18, 16.24), RL -0.804 mmHg (-12.65, 11.04); for infants 751-1,000 g: RA 3.535 mmHg (-9.6, 16.7), RL -1.239 mmHg (-13.14, 10.66); for infants above 1,000 g: RA -1.65 mmHg (-13.47, 10.17), RL -4.101 mmHg (-14.17, 5.96). CONCLUSIONS: Although the average differences between invasive and non-invasive BP measurements are acceptable, the range of under- and overestimation of non-invasive BP measurements is large and not consistent, making reliance on non-invasive modalities to guide circulatory management problematic. If arterial BP monitoring is not available, our results suggest measuring non-invasive BP on the leg in preterm infants with a birth weight no greater than 1,000 g.
Authors:
Kai König; Dan M Casalaz; Emily J Burke; Andrew Watkins
Related Documents :
12897998 - Effect of forced deflation maneuvers upon measurements of respiratory mechanics in vent...
16369918 - Lung function tests in neonates and infants with chronic lung disease: global and regio...
15018448 - Amniotic sac infection syndrome features fetal lung neuroendocrine cell hyperfunction.
575008 - Is the aeration of the lungs a reliable sign of live birth?
21528008 - Neural mirroring systems: exploring the eeg μ rhythm in human infancy.
17687828 - Epidemiology of neural tube defects in northern iran, 1998-2003.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-3-6
Journal Detail:
Title:  Intensive care medicine     Volume:  -     ISSN:  1432-1238     ISO Abbreviation:  -     Publication Date:  2012 Mar 
Date Detail:
Created Date:  2012-3-6     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7704851     Medline TA:  Intensive Care Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Paediatrics, Mercy Hospital for Women, 163 Studley Road, Melbourne, VIC, 3084, Australia, kaikonig@gmail.com.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A smart porphyrin cage for recognizing azide anions.
Next Document:  International evidence-based recommendations for point-of-care lung ultrasound.