Document Detail


Accuracy in gamma camera measurements of point source velocities.
MedLine Citation:
PMID:  10894565     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Mucociliary clearance is impaired in many diseases of the respiratory system. We have developed a method for measuring tracheal mucus velocity by the dynamic study of a single point source of radioactivity deposited in the trachea by cricothyroid injection. Preliminary results suggest that patients with airways disease have very low tracheal mucus velocities (<2 mm x min(-1)). The aim of this experiment was to explore the ability of current scintillation detection systems to track a single point as it moves in a dynamic study in small increments and at low velocity (movements of the order of 1 mm). Background noise was estimated to contribute an error in positioning of 0.16 mm (1 standard deviation). Overall errors in velocity were estimated at 0.2 mm x min(-1). This suggests that standard instrumentation in use in most nuclear medicine departments has the capacity to measure accurately velocities as low as 1 mm x min(-1).
Authors:
L C Morgan; M A Pearson; D W Mackey; J Rutland; R U de Iongh; M J Peters; H van der Wall
Related Documents :
3864375 - Treatment-induced errors in occlusion following orthognathic surgery.
11764025 - Method of identifying dynamic multileaf collimator irradiation that is highly sensitive...
20687275 - Minimization of displacement estimation bias due to high amplitude-reflections using en...
11079885 - Error analysis using organizational simulation.
24575315 - Body fat mass assessment: a comparison between an ultrasound-based device and a discove...
20117825 - Effect of prothrombin time outlier exclusion rules on isi calibration in multicentre st...
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Nuclear medicine communications     Volume:  21     ISSN:  0143-3636     ISO Abbreviation:  Nucl Med Commun     Publication Date:  2000 Jun 
Date Detail:
Created Date:  2000-11-21     Completed Date:  2000-11-21     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8201017     Medline TA:  Nucl Med Commun     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  553-6     Citation Subset:  IM    
Affiliation:
Department of Respiratory Medicine, Concord Repatriation General Hospital, NSW, Australia. lucy@rfu.crg.cs.nsw.gov.au
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Gamma Cameras*
Humans
Mucociliary Clearance*
Radionuclide Imaging / instrumentation,  methods
Reproducibility of Results
Respiratory Tract Diseases / physiopathology*,  radionuclide imaging*
Trachea / radionuclide imaging