Document Detail


Accuracy assessment of a novel blood pressure measurement device in a South African adult population: Tensoval duo control.
MedLine Citation:
PMID:  22027814     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: The Tensoval duo control device uses a novel combination of auscultatory and oscillometric technology to measure blood pressure. We assessed the accuracy of this device in a South African adult population according to the International Protocol of the European Society of Hypertension. METHODS: Ethical approval was obtained and 33 participants were recruited from Kimberley Hospital Complex (South Africa). Trained observers took sequential same arm blood pressure measurements from each participant, alternating between mercury sphygmomanometery and the device. RESULTS: The Tensoval duo control passed all the phases of the protocol and achieved a mean difference±SD of -3.2±7.2 and 2.0±6.0 mmHg for systolic and diastolic pressures, respectively. CONCLUSION: This study confirms the accuracy and recommendation for clinical use of the Tensoval duo control device in adults. Accuracy in special patient groups is yet to be assessed, but this novel technology could be particularly valuable in those with vascular disease.
Authors:
Annemarie de Greeff; Natasha Hezelgrave; Andrew H Shennan
Related Documents :
9659014 - The effect of increasing degrees of spinal flexion on cerebrospinal fluid pressure.
2732734 - Study of brain tissue impedance in the hydrocephalic cat.
1087134 - Cerebrospinal fluid pressure during o2 encephalography and n2o inhalation.
21270814 - Assessment of aortic stiffness by local and regional methods.
10077414 - Effects of antihypertensive single-drug therapy on heart rate. department of veterans a...
22487234 - Capillary rise in hele-shaw models of disordered media.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-10-24
Journal Detail:
Title:  Blood pressure monitoring     Volume:  -     ISSN:  1473-5725     ISO Abbreviation:  -     Publication Date:  2011 Oct 
Date Detail:
Created Date:  2011-10-26     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Women's Academic Health Centre, King's Health Partners, King's College London, St Thomas' Hospital, London SE1 7EH, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex