Accuracy of a Novel System for Oxygen Delivery to Small Children.
MedLine Citation:
PMID:  21727103     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Objective: Oxygen therapy for infants and small children in developing countries is often not available. Entrainment devices may provide an accurate and precise concentration of oxygen when used at the flow rates appropriate for infants and small children. Methods: A continuously adjustable entrainment device was tested to determine the concentrations and flows of oxygen delivered by using low inlet flow rates suitable for therapy for infants and small children and 3 distinct oxygen delivery systems that varied in their resistive load. Results: The use of long and large bore, low resistance tubing (similar to a mask) resulted in the delivery of oxygen concentrations that tracked closely (accurate and precise) to values indicated by the entrainment device. The directly connected system with lower resistance (similar to a hood) produced a similar profile of concentrations and flow rates to the large bore tubing but with even greater accuracy. The use of a long and narrow tubing with higher resistance (similar to a cannula) did not deliver accurate oxygen concentrations. In fact, this high-resistance system failed to work as intended, and instead of entraining air, a large proportion (sometimes >50%) of the oxygen delivered to the entrainment device was ejected through its vents. Conclusions: Entrainment devices can deliver accurate oxygen concentrations at low flow rates if used with low resistance delivery systems; however, entrainment devices are not suitable for use with high resistance delivery systems such as a standard nasal cannula.
Authors:
Matthew Coghill; Namasivayam Ambalavanan; Robert L Chatburn; Patricia L Hibberd; Linda L Wright; Waldemar A Carlo;
Related Documents :
16552743 - Leucocyte depletion improves renal function during reperfusion using an experimental is...
8847863 - Validation of transonic small animal flowmeter for measurement of cardiac output and re...
7328143 - Canine cerebral metabolism and blood flow during hypoxemia and normoxic recovery from h...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-7-4
Journal Detail:
Title:  Pediatrics     Volume:  -     ISSN:  1098-4275     ISO Abbreviation:  -     Publication Date:  2011 Jul 
Date Detail:
Created Date:  2011-7-5     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0376422     Medline TA:  Pediatrics     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Pediatrics, University of Alabama at Birmingham, Birmingham, Alabama;
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dermatophytid in Tinea Capitis: Rarely Reported Common Phenomenon With Clinical Implications.
Next Document:  Longitudinal Changes in Active Transportation to School in Canadian Youth Aged 6 Through 16 Years.