Document Detail


Accuracy of the Doppler-derived pressure gradient in pediatric patients with aortic valvular stenosis: is the correction for pressure recovery necessary?
MedLine Citation:
PMID:  20718206     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The Doppler echocardiography derived peak instantaneous systolic pressure gradient (peak instantaneous Doppler PG), the mean PG (mean Doppler PG) and the aortic valvular area are the accepted standard for determining the prognosis and optimal timing of intervention because of good agreement between Doppler-derived and catheter-measured PGs in adult patients with aortic valvular stenosis. However, several investigators reported that pressure recovery can cause discrepancies between Doppler-derived and catheter-measured PGs, so that the correction for pressure recovery has been proposed. In pediatric patients with aortic valvular stenosis, the discrepancy between Doppler-derived and catheter-measured PGs and the correction for pressure recovery have not been studied well. Therefore, the purpose of current study was to clarify the role of echocardiography for estimating the prognosis and optimal timing of intervention and to assess the influence of pressure recovery on the Doppler-derived PG in pediatric patients with aortic valvular stenosis. Thirteen pediatric patients with aortic valvular stenosis were studied with echocardiography and cardiac catheterization. PG determined by the catheterization was compared with PG determined by the echocardiography with linear regression and Bland and Altman analysis. As result, Doppler-derived PGs corrected for pressure recovery did not correlated well with catheter-measured PGs. By contrast, Doppler-derived PGs correlated well with catheter-measured PGs. In particular, the mean Doppler PG correlated excellently with the mean catheter PG. In conclusion, the mean Doppler PG demonstrated an excellent correlation with the mean catheter PG without the correction for pressure recovery. Thus, the mean Doppler PG is useful in order to determine the prognosis and optimal timing of intervention in pediatric patients with aortic valvular stenosis.
Authors:
Hirokuni Yamazawa
Related Documents :
1386746 - Doppler color imaging. peripheral arteries.
19078936 - Pressure-polishing pipettes for improved patch-clamp recording.
17708156 - Optional active compliance chamber performance in a pulmonary artery-pulmonary artery c...
2588246 - Jamming of prosthetic heart valves by suture trapping: experimental findings.
2059106 - Foot pressure distribution during walking and shuffling.
19855906 - Glomerular filtration is reduced by high tidal volume ventilation in an in vivo healthy...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  [Hokkaido igaku zasshi] The Hokkaido journal of medical science     Volume:  85     ISSN:  0367-6102     ISO Abbreviation:  Hokkaido Igaku Zasshi     Publication Date:  2010 Jul 
Date Detail:
Created Date:  2010-08-19     Completed Date:  2010-09-14     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  17410290R     Medline TA:  Hokkaido Igaku Zasshi     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  225-31     Citation Subset:  IM    
Affiliation:
Department of Pediatrics, Hokkaido University Graduate School of Medicine, Sapporo 060-8638, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aortic Valve Stenosis / diagnosis*,  surgery
Blood Pressure Determination*
Child
Child, Preschool
Echocardiography, Doppler*
Female
Heart Catheterization
Humans
Infant
Male
Prognosis

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine