Document Detail


Access monitoring is worthwhile and valuable.
MedLine Citation:
PMID:  16361846     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
During the past several years, a limited number of small clinical trials have questioned the role of surveillance in the management of vascular accesses, since the prolongation of access longevity until replacement was not altered. Although prolongation of access life span is an important endpoint, it is not the only one. Reduction in thrombotic events reduces the risks to the patient resulting from loss of access patency. The body of evidence suggests that the detection of stenosis and prevention of thrombosis are valuable. When a test indicates the likely presence of a stenosis, venography or fistulography should be used to definitely establish the presence and the degree of the stenosis. In most cases, angioplasty should be performed if the stenosis is greater than 50% by diameter. The value of routine use of any surveillance technique for detecting anatomic stenosis alone without concomitant functional assessment by measurement of access flow, venous pressure, recirculation, or other physiologic parameter has not been established. Stenotic lesions should not be repaired merely because they are present. If such correction is performed, then intra-procedural studies of access flow or intra-access pressure prior to and following percutaneous transluminal angioplasty should be conducted to demonstrate a functional improvement with a 'successful' percutaneous transluminal angioplasty.
Authors:
Anatole Besarab
Related Documents :
2973376 - Coronary artery vasoconstriction routinely occurs after percutaneous transluminal coron...
1564226 - Failure of angiography to accurately depict the extent of coronary artery narrowing in ...
8881736 - Duplex-guided compression of femoral artery false aneurysms reduces the need for surgery.
22152296 - Pseudoaneurysm of the left ventricle following apical approach tavi.
15944606 - Laparoscopic aortic reinforcement and endovascular graft placement in swine: a new exte...
23340486 - Pulsatile haemodynamic parameters are predictors of survival in paediatric pulmonary ar...
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Blood purification     Volume:  24     ISSN:  0253-5068     ISO Abbreviation:  Blood Purif.     Publication Date:  2006  
Date Detail:
Created Date:  2005-12-19     Completed Date:  2006-03-23     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8402040     Medline TA:  Blood Purif     Country:  Switzerland    
Other Details:
Languages:  eng     Pagination:  77-89     Citation Subset:  IM    
Copyright Information:
Copyright 2006 S. Karger AG, Basel.
Affiliation:
Division of Nephrology and Hypertension, Department of Medicine, Henry Ford Hospital, Detroit, MI 48301, USA. abesarab@ghsrenal.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Catheters, Indwelling* / adverse effects
Constriction, Pathologic / etiology,  prevention & control
Humans
Monitoring, Physiologic* / methods,  trends
Renal Dialysis*
Thrombosis / etiology,  prevention & control

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A critical assessment of uremia research.
Next Document:  Strategies to minimize tunneled hemodialysis catheter use.