The purpose of this study was to document the torque and range of motion parameters generated on the lsostation B100 by subacute low back pain patients 2-7 days postinjury. Abnormal values found in this study were compared to normal values found in a previous study. One hundred and forty-three males and 29 females were evaluated in a predetermined combination of three tests. These included: a) range of motion in each plane, b) repetitive flexion/extension, and c) a modified maximum lift. The results of the investigation indicate significant differences (p = 0.01) in parameters generated by the lsostation B100 between normals and abnormals in each test. Discrepancies between normals and abnormals were greater for females than males. Torque output was most significantly affected (p = 0.01) in the axis of flexion/extension for both males and females. Range of motion was most significantly affected (p = 0.01) in extension for both males and females. In test b (the flexion/extension repetitive test), the most significant (p = 0.01) percent reduction in torque and range of motion values occurred in the secondary axis of rotation and lateral flexion rather than flexion/extension. This reduced crossover activity, crosstalk, may be an indicator of guarded effort, poor effort or both. The lsostation B100 is a valuable tool as it provides objective information on torque output and range of motion for the low back.J Orthop Sports Phys Ther 1988;10(4):121-133.
Authors:
R H Seeds; J A Levene; H M Goldberg
Related Documents :
17207429 - Variation of the distal metatarsal articular angle with axial rotation and inclination ...
18091489 - Immature sheep spines are more flexible than mature spines: an in vitro biomechanical s...
20375779 - Motion changes in adjacent segments due to moderate and severe degeneration in c5-c6 di...
1502639 - Diurnal changes in the profile shape and range of motion of the back.
20065869 - Normal functional range of motion of the lumbar spine during 15 activities of daily liv...
19585159 - Local and global subaxial cervical spine biomechanics after single-level fusion or cerv...
24834009 - In vivo measurements of flexor tendon and suspensory ligament forces during trotting us...
15866839 - Therapeutic ultrasound in lower extremity wound management.
20211709 - Collective movements, initiation and stops: diversity of situations and law of parsimony.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Journal of orthopaedic and sports physical therapy     Volume:  10     ISSN:  0190-6011     ISO Abbreviation:  J Orthop Sports Phys Ther     Publication Date:  1988  
Date Detail:
Created Date:  2008-09-17     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7908150     Medline TA:  J Orthop Sports Phys Ther     Country:  United States    
Other Details:
Languages:  eng     Pagination:  121-33     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Comparison of three methods of assessing strength imbalances at the knee.
Next Document:  Entrapment neuropathy of the lateral femoral cutaneous nerve: cause of lateral knee pain.