64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV.
MedLine Citation:
PMID:  23034796     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BackgroundThe radiation dose of coronary computed tomography (CT) angiography (CCTA) is generally higher than that of CT scans of other parts of the body, and there is concern that the high radiation dose may result in increased cancer risk. Although various techniques have recently been introduced to lower the radiation dose of CCTA, there has been no direct comparison between protocols with 80 and 120 kV.PurposeTo assess the image quality and radiation dose of 80-kV electrocardiography (ECG)-gated CCTA in subjects with a normal body mass index (BMI), compared to 120-kV ECG-gated CCTA.Material and MethodsThis retrospective study was approved by our local ethics board, and the requirement of written informed consent was waived. We analyzed the CCTA images of 100 subjects with BMIs <25 kg/m(2). Fifty subjects underwent 120-kV CCTA, and the other 50 subjects underwent 80-kV CCTA. Two blinded observers independently evaluated the subjective image quality of the coronary arteries. The objective image quality (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) and radiation dose were also measured in each group.ResultsAlthough the objective image quality of the 80-kV protocol images was significantly poorer than that of 120-kV protocol images (mean SNR, 14.9 ± 4.7 vs. 19.8 ± 4.4, P < 0.0001; mean CNR, 15.2 ± 4.8 vs. 21.6 ± 4.7, P < 0.0001), there was no significant difference in the subjective image quality between the two groups (mean image score, 4.7 ± 1.1 vs. 4.5 ± 0.7 for radiologist 1, P = 0.273; 5.0 ± 1.0 vs. 4.8 ± 1.0 for radiologist 2, P = 0.197). The radiation dose was reduced by 70% with the 80-kV protocol and by 88% with the 80-kV and ECG-based tube current modulation than with the 120-kV protocol (3.42 ± 1.16 and 2.9 ± 0.8 vs. 11.49 ± 3.62 mSv, P < 0.0001).ConclusionThe low tube voltage CCTA protocol using 80 kV allows significant reduction of the radiation dose without impairing the subjective image quality in subjects with normal BMIs.
Authors:
Bo Ram Jun; Hwan Seok Yong; Eun-Young Kang; Ok Hee Woo; Eun Jung Choi
Related Documents :
23556896 - Mass detection in reconstructed digital breast tomosynthesis volumes with a computer-ai...
2928386 - On the existence of an unambiguous solution in factor analysis of dynamic studies.
24586526 - Image-derived input function derived from a supervised clustering algorithm: methodolog...
23892996 - Improving n-wire phantom-based freehand ultrasound calibration.
20161796 - Blue fluorescent cgmp sensor for multiparameter fluorescence imaging.
24366726 - Invention and validation of an automated camera system that uses optical character reco...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-3
Journal Detail:
Title:  Acta radiologica (Stockholm, Sweden : 1987)     Volume:  -     ISSN:  1600-0455     ISO Abbreviation:  Acta Radiol     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8706123     Medline TA:  Acta Radiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Mortality from asbestosis and mesothelioma in Britain by birth cohort.
Next Document:  Cefotaxime-eluting covered self-expandable stents in a canine biliary model: scanning electron micro...