4D CT image acquisition errors in SBRT of liver identified using correlation.
MedLine Citation:
PMID:  22231209     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
In the AAPM Report 80,(1) the imaging modality of 4D CT and respiration-correlated CT was declared a "promising solution for obtaining high-quality CT data in the presence of respiratory motion". To gather anatomically correct data over time, the existence of correlation between the internal organ movement and an external surrogate has to be assumed. For the in-house evaluation of such correlation, we retrospectively analyzed 21 four-dimensional computer tomography (4D CT) scans of five patients, out of which the artifacts experienced in three patients are shown here. To provide context and a baseline for the analysis of patient motion, a real-tissue liver phantom was used with a solid water block and liver tissue. The superior-inferior motion of fiducials in phantom and patients was correlated to the recorded anterior-posterior motion of an external surrogate marker on the chest. The use of a solid water block yielded a measurable correlation coefficient of 0.98 or better using a sinusoidal animation pattern. With sinusoidally-animated liver tissue, the minimum correlation observed was 0.96. Comparing this to retrospective patient data, we found three cases of a change in the correlation coefficient, or simply a low correlation. The source of this low correlation was investigated by careful examination of the breathing traces and the CT-phase assignments used to reconstruct the datasets. Consequences of nonregular breathing are elaborated on. We demonstrate the impact of wrong phase assignments and missing image information in the 4D CT phase sampling processes. We also show how daily patient-based correlation analysis can indicate changes in breathing traces, which can be significant enough to decrease, or completely eliminate, previously existing correlation.
Authors:
Martin Szegedi; Vikren Sarkar; Prema Rassiah-Szegedi; Brian Wang; Y Jessica Huang; Hui Zhao; Bill Salter
Related Documents :
17044559 - In vivo accuracy of image guidance performed using optical tracking and optimized regis...
6367649 - A multipurpose ct-guided stereotactic instrument of simple design.
22038389 - Clinical feasibility study for detection of myocardial oedema by a cine ssfp sequence i...
6361079 - Stereotactic biopsy using computed tomography.
21993179 - Role of multidetector ct angiography in the evaluation of suspected mesenteric ischemia.
3301189 - Computed tomographic analysis of bilateral cingulotomy for intractable mood disturbance...
21623229 - Mri restricted diffusion in lymphomatous optic neuropathy.
10030249 - Prognostic factors of nasopharynx tumors investigated by mr imaging and the value of mr...
1333999 - Magnetic resonance imaging of krukenberg tumor from gastric cancer.
Publication Detail:
Type:  Journal Article     Date:  2012-01-05
Journal Detail:
Title:  Journal of applied clinical medical physics / American College of Medical Physics     Volume:  13     ISSN:  1526-9914     ISO Abbreviation:  J Appl Clin Med Phys     Publication Date:  2012  
Date Detail:
Created Date:  2012-01-10     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101089176     Medline TA:  J Appl Clin Med Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  3564     Citation Subset:  IM    
Affiliation:
University of Utah. martin.szegedi@hci.utah.edu.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Establishing the quality management baseline in the use of computed tomography machines in Kenya.
Next Document:  A quality assurance tool for helical tomotherapy using a step-wedge phantom and the on-board MVCT de...