Document Detail


A 122Xe-122I generator for remote radio-iodinations.
MedLine Citation:
PMID:  3019939     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A 122Xe-122I generator system is described that produces 122I extraction efficiencies of approximately 60%. Radiocontaminants were less than 0.1% at the time of 122I removal following a 10 min ingrowth period. The chemical form of 122I was identified as [122I]iodide, and the [122I]iodide was remotely incorporated into radiopharmaceuticals for PET studies with an overall efficiency of as much as 40%.
Authors:
C A Mathis; M C Lagunas-Solar; T Sargent; Y Yano; A Vuletich; L J Harris
Related Documents :
6546559 - Esmis--a computer-based emergency medical services management information system. part ...
23524929 - Participation in medicine by graduates of medical schools in the united kingdom up to 2...
20543389 - Patient safety, resilience and ict. a reason for concern?
17051309 - Computer-interpretable clinical practice guidelines. where are we and where are we going ?
16862739 - A method for describing and evaluating naturopathic whole practice.
12695769 - The effect of ligation method on friction in sliding mechanics.
10334829 - A new hazardous waste index.
21203599 - The ankle-brachial index-a classification of the patient education websites.
20481359 - The medical collections at the university of glasgow.
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, Non-P.H.S.; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes     Volume:  37     ISSN:  0883-2889     ISO Abbreviation:  Int J Rad Appl Instrum A     Publication Date:  1986  
Date Detail:
Created Date:  1986-11-20     Completed Date:  1986-11-20     Revised Date:  2009-06-04    
Medline Journal Info:
Nlm Unique ID:  8611097     Medline TA:  Int J Rad Appl Instrum A     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  258-60     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Iodine Radioisotopes*
Isotope Labeling / instrumentation*
Radionuclide Generators
Tomography, Emission-Computed
Grant Support
ID/Acronym/Agency:
MH 36801-02/MH/NIMH NIH HHS
Chemical
Reg. No./Substance:
0/Iodine Radioisotopes

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Preparation of 99mTc-tin-phosphate polyvinyl pyrollidone stabilized colloid and distribution in bone...
Next Document:  Licencing of medical x-ray equipment in 1899: background and procedure.