| A 122Xe-122I generator for remote radio-iodinations. | |
| | |
MedLine Citation:
|
PMID: 3019939 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
A 122Xe-122I generator system is described that produces 122I extraction efficiencies of approximately 60%. Radiocontaminants were less than 0.1% at the time of 122I removal following a 10 min ingrowth period. The chemical form of 122I was identified as [122I]iodide, and the [122I]iodide was remotely incorporated into radiopharmaceuticals for PET studies with an overall efficiency of as much as 40%. |
| | |
Authors:
|
C A Mathis; M C Lagunas-Solar; T Sargent; Y Yano; A Vuletich; L J Harris |
Related Documents
:
|
6546559 - Esmis--a computer-based emergency medical services management information system. part ... 23524929 - Participation in medicine by graduates of medical schools in the united kingdom up to 2... 20543389 - Patient safety, resilience and ict. a reason for concern? 17051309 - Computer-interpretable clinical practice guidelines. where are we and where are we going ? 16862739 - A method for describing and evaluating naturopathic whole practice. 12695769 - The effect of ligation method on friction in sliding mechanics. 10334829 - A new hazardous waste index. 21203599 - The ankle-brachial index-a classification of the patient education websites. 20481359 - The medical collections at the university of glasgow. |
Publication Detail:
|
Type: Journal Article; Research Support, U.S. Gov't, Non-P.H.S.; Research Support, U.S. Gov't, P.H.S. |
Journal Detail:
|
Title: International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes Volume: 37 ISSN: 0883-2889 ISO Abbreviation: Int J Rad Appl Instrum A Publication Date: 1986 |
Date Detail:
|
Created Date: 1986-11-20 Completed Date: 1986-11-20 Revised Date: 2009-06-04 |
Medline Journal Info:
|
Nlm Unique ID: 8611097 Medline TA: Int J Rad Appl Instrum A Country: UNITED STATES |
Other Details:
|
Languages: eng Pagination: 258-60 Citation Subset: IM |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Iodine Radioisotopes* Isotope Labeling / instrumentation* Radionuclide Generators Tomography, Emission-Computed |
| Grant Support | |
ID/Acronym/Agency:
|
MH 36801-02/MH/NIMH NIH HHS |
| Chemical | |
Reg. No./Substance:
|
0/Iodine Radioisotopes |