| Results 701 - 750 of 1399 | ||
| < 10 11 12 13 14 15 16 17 18 19 20 > | ||
|
Song Yi-Qiao - - 2004
This paper describes an NMR method capable of determining the diffusion constant of a material within a few milliseconds and without the need of multiple scans. The method can be used with static or pulsed magnetic field gradients. It may be used to detect time-dependent processes, such as in chemical ...
|
||
|
Lewis Emma B - - 2004
Longitudinal MR imaging is increasingly being used to measure cerebral atrophy progression in dementia and other neurological disorders. Differences in intensity inhomogeneity between serial scans can confound these measurements. This differential bias also distorts nonlinear registration and makes both manual and automated segmentation of tissue type less reliable. A technique ...
|
||
|
Bradley P G - - 2004
BACKGROUND AND OBJECTIVE: For use in a magnetic resonance (MR) scanning room infusion pumps must be MR safe and compatible. This study tested two commonly used infusion pumps (Alaris P6000 and Alaris Asena-GH) to determine if they met these criteria. METHODS: The pumps underwent testing within the scanning room of ...
|
||
|
Denslow Stewart - - 2004
OBJECTIVE: Using functional magnetic resonance imaging, we assessed variation in location and intensity of blood oxygen level-dependent contrast associated with movements induced by transcranial magnetic stimulation or volition. BACKGROUND: Anatomic location and within-subject repeatability of blood oxygen level-dependent responses induced by transcranial magnetic stimulation comprise critical information to the use ...
|
||
|
Buess M - - 2004
Thin-circular lithographically defined magnetic elements with a spin vortex configuration are excited with a short perpendicular magnetic field pulse. We report the first images of excited magnetic eigenmodes up to third order, obtained by means of a phase sensitive Fourier transform imaging technique. Both axially symmetric and symmetry breaking azimuthal ...
|
||
|
Wajnberg Eliane - - 2004
Pachycondyla marginata (P.m.), a migratory and termitophageous ant, hunting only the termite species Neocapritermes opacus, migrates significantly oriented 13 degrees with respect to the magnetic North-South axis. Results of hysteresis curves at room temperature of four Pachycondyla marginata heads, thorax, pairs of antennae and abdomens, oriented parallel to the magnetic ...
|
||
|
Nishi Takaaki - - 2004
Magnetosensitivity of the Japanese eel, Anguilla japonica, was examined by conditioning and electrocardiography. Marine eels, river eels and farmed eels were conditioned to an imposed magnetic field ranging from 12,663 nT to 192,473 nT parallel to the fish body, which was placed along the earth's west-east axis. Electrocardiograms were recorded ...
|
||
|
Wackym P Ashley - - 2004
OBJECTIVE: Magnetic resonance imaging (MRI) has been contraindicated when cochlear implants containing an internal magnet are in place because of concerns regarding torque, force, demagnetization, artifacts, induced voltages, and heating. The objective was to determine the magnetic field strength of Med-El Combi 40+ cochlear implant internal magnets after MRI studies. ...
|
||
|
Babincová M - - 2004
We have evaluated heating capabilities of new magnetic nanoparticles. In in vitro experiments they were exposed to an alternating magnetic field with frequency 3.5 MHz and induction 1.5 mT produced in three turn pancake coil. In in vivo experiments rats with injected magnetic nanoparticles were also exposed to an ac ...
|
||
|
Tokunaga M - - 2004
Local magnetization and current distribution in (La(1-y)Pr(y))0.7Ca0.3MnO3 (y=0.7) crystals are studied by a magneto-optical (MO) imaging technique. MO images below 120 K visualize inhomogeneous magnetization and conduction paths that manifest the percolative conduction originated from the mesoscopic phase separation into ferromagnetic metals and antiferromagnetic insulators. Application of large amounts of ...
|
||
|
Suzuki Junko - - 2004
PURPOSE: To compare the pattern of visual field damage between normal-tension glaucoma (NTG) patients with signs indicative of ischemic changes and those NTG patients without signs of ischemic changes, using brain magnetic resonance imaging (MRI), in a single center, cross-sectional study. METHODS: In 94 consecutive NTG patients who were younger ...
|
||
|
Ruggiero Marco - - 2004
Inhibition of angiogenesis is a major target in the fight against cancer and other diseases. Although the effects of static magnetic fields on cancer development and cell growth have been investigated, effects on angiogenesis have received no attention so far. In this study we report the effects on angiogenesis of ...
|
||
|
Fiek Michael - - 2004
The purpose of this case report is to describe the effects of an MRI performed on a patient without realizing that an ICD has been previously implanted. After a few seconds of imaging the adversity was recognized and the examination was stopped immediately. The patient was not pacemaker dependent and ...
|
||
|
Bonetto F - - 2004
Proton field-cycling nuclear magnetic resonance relaxometry is used to study the spin-lattice relaxation dispersion of selected standard smectic A liquid crystals at different temperatures. Relaxation features at both, in the presence and absence of a monochromatic ultrasonic field are considered. We show that the laboratory-frame spin-lattice relaxation time is mainly ...
|
||
|
Sood, S.
An attempt was made to correlate various types of visual field defects on automated perimetry with the findings of computed tomography in 44 patients of supratentorial tumors. All the patients above the age of 10 years were subjected to complete neurological examination including investigations like plain X-rays and CT scan, ...
|
||
|
Freedman Kenn A - - 2004
PURPOSE: To report a case of a transient homonymous hemianopia in a patient with nonketotic hyperglycemia with negative magnetic resonance imaging (MRI) scans. DESIGN: Case report. METHOD: A 72-year-old woman with diabetes mellitus was referred to the neuro-ophthalmology service with hyperglycemia and multiple visual complaints. RESULTS: The patient was found ...
|
||
|
Rannacher Dirk - - 2004
We consider a horizontal ferrofluid layer sandwiched between two layers of immiscible nonmagnetic fluids. In a sufficiently strong vertical magnetic field the flat interfaces between magnetic and nonmagnetic fluids become unstable to the formation of peaks. We theoretically investigate the interplay between these two instabilities for different combinations of the ...
|
||
|
Alves O C - - 2004
Temperature dependence of the magnetic resonance is used to study the magnetic material in oriented Neocapritermes opacus (N.o.) termite, the only prey of the migratory ant Pachycondyla marginata (P.m.). A broad line in the g = 2 region, associated to isolated nanoparticles shows that at least 97% of the magnetic ...
|
||
|
Shang Gui-Min - - 2004
The growth of suspension cultures of Taxus chinensis var. mairei and Taxol production were promoted both by a sinusoidal alternating current magnetic field (50 Hz, 3.5 mT) and by a direct current magnetic field (3.5 mT). Taxol production increased rapidly from the 4th d with the direct current magnetic field ...
|
||
|
Kelly Thomas F - - 2004
The first dedicated local electrode atom probes (LEAP [a trademark of Imago Scientific Instruments Corporation]) have been built and tested as commercial prototypes. Several key performance parameters have been markedly improved relative to conventional three-dimensional atom probe (3DAP) designs. The Imago LEAP can operate at a sustained data collection rate ...
|
||
|
Beck Barbara L - - 2004
Proton MRI of large biological samples were obtained on an 11.1 T / 40 cm instrument. Images were obtained of a fixed human brain and a large piece of fresh beef. The proton MR images demonstrate severe distortions within these conductive samples, indicative of shortened electrical wavelengths and wave behavior ...
|
||
|
Hur N - - 2004
Ferroelectric and magnetic materials are a time-honoured subject of study and have led to some of the most important technological advances to date. Magnetism and ferroelectricity are involved with local spins and off-centre structural distortions, respectively. These two seemingly unrelated phenomena can coexist in certain unusual materials, termed multiferroics. Despite ...
|
||
|
Bauer A - - 2004
We present magnetization measurements of mesoscopic superconducting niobium loops containing a ferromagnetic (PdNi) pi junction. The loops are prepared on top of the active area of a micro-Hall sensor based on high mobility GaAs/AlGaAs heterostructures. We observe asymmetric switching of the loop between different magnetization states when reversing the sweep ...
|
||
|
Substantial reduction of critical current for magnetization switching in an exchange-biased spin ...
Jiang Y - - 2004
Great interest in current-induced magnetic excitation and switching in a magnetic nanopillar has been caused by the theoretical predictions of these phenomena. The concept of using a spin-polarized current to switch the magnetization orientation of a magnetic layer provides a possible way to realize future 'current-driven' devices: in such devices, ...
|
||
|
Nestle Nikolaus - - 2004
In contrast to transverse nuclear magnetizations, longitudinal spin magnetizations are usually considered as insensitive to magnetic field gradients. While this assumption is valid for homogeneously excited samples, the apparent longitudinal spin relaxation behavior of thin magnetization slices in high magnetic fields is strongly modified by diffusion. In this contribution, we ...
|
||
|
Flores M S - - 2004
PM2000 is a ferritic alloy obtained by powder metallurgy and is being investigated for potential applications as a biomaterial. This work aimed to assess the biological compatibility and to determine the influence of the processing route and further recrystallisation treatment on the magnetic behaviour. The magnetic behaviour has been analysed ...
|
||
|
Li Lin - - 2004
Magnetic susceptibility, as a physical property of materials, plays important roles in many physical, chemical, engineering, and medical applications. Its quantification becomes of significant interest when MRI becomes a commonly used technique in biomedical applications. A general method is presented here for quantifying arbitrary magnetic susceptibility distributions in a localized ...
|
||
|
Rakvin B - - 2004
We outline a spectroscopic method for probing the effective magnetic field B on the surface of crystals of the single molecule magnet (SMM) [(C6H15N3)6Fe8(mu3-O)2(mu2-OH)12]Br7(H2O)Br.H2O, (Fe8Br8). This technique utilizes the line shape changes in the EPR spectra of the organic radical 2,2-diphenyl-1-picrylhydrazyl (DPPH) (g = 2.0036, single peak) adsorbed onto the ...
|
||
|
Matteucci G - - 2004
We have used electron holography to perform quantitative investigations of the leakage flux of thin film tips used as probes in magnetic force microscopy. A method to deduce an arrangement of magnetic domains in a thin magnetic whisker from the knowledge of the stray flux is also described. A simple ...
|
||
|
Bergman Jonathan - - 2004
CONTEXT: Magnetic fields have been found to affect neuromuscular function. OBJECTIVE: To study the effect of a magnetic field on measurements of urethral function in women with stress urinary incontinence. DESIGN: Observational comparative study. SETTING: Consecutive patients in a continence center. PATIENTS OR OTHER PARTICIPANTS: Twenty-six consecutive women with diagnosis ...
|
||
|
Uematsu Hidemasa - - 2004
Whole-body magnetic resonance (MR) scanners at high field strengths (> or =3 T) have been introduced in expectation of a larger signal-to-noise ratio (SNR), which would decrease the length of scan time or improve the spatial resolution. In this paper, the advantages and disadvantages of the high field MR imaging ...
|
||
|
Rezai Ali R - - 2004
The use of magnetic resonance imaging (MRI) in patients with neurostimulation systems used for deep brain stimulation requires the utmost care, and no individual should undergo an MR examination in the absence of empirical evidence that the procedure can be performed safely. The risks of performing MRI in patients with ...
|
||
|
Yamanouchi M - - 2004
Magnetic information storage relies on external magnetic fields to encode logical bits through magnetization reversal. But because the magnetic fields needed to operate ultradense storage devices are too high to generate, magnetization reversal by electrical currents is attracting much interest as a promising alternative encoding method. Indeed, spin-polarized currents can ...
|
||
|
Hayashi Naoto - - 2004
The evident advantage of high-field MR (magnetic resonance) scanners is their higher signal-to-noise ratio, which results in improved imaging. While no reliable efficacy studies exist that compare the diagnostic capabilities of low- versus high-field scanners, the adoption and acceptance of low-field MRI (magnetic resonance imaging) is subject to biases. On ...
|
||
|
Taouli Bachir - - 2004
OBJECTIVE: The purpose of this study was to compare the relative results from conventional high-field-strength 1.5-T MRI, 0.2-T low-field-strength dedicated extremity MRI, and radiography to detect and grade bone erosions, joint-space narrowing, and synovitis in the hands and wrists of patients with rheumatoid arthritis. SUBJECTS AND METHODS: Eighteen patients with ...
|
||
|
Vickers Elaine B - - 2004
A new organic-based magnet, V[TCNP]2.yCH2Cl2 (TCNP = tetracyanopyrazine), has been synthesized, and its magnetic properties have been examined. The amorphous nature of V[TCNP]2.yCH2Cl2 makes it difficult to determine the structure of the material; however, ac and dc magnetic measurements indicate that it is a ferrimagnet below 200 K with a ...
|
||
|
Puntes Victor F - - 2004
The use of magnetic nanoparticles in the development of ultra-high-density recording media is the subject of intense research. Much of the attention of this research is devoted to the stability of magnetic moments, often neglecting the influence of dipolar interactions. Here, we explore the magnetic microstructure of different assemblies of ...
|
||
|
Franz P - - 2004
We describe in this Letter the first measurement of multiple islands in the core of a reversed field pinch (RFP). These islands appear with current profile modification leading to magnetic fluctuation reduction in the Madison symmetric torus RFP. Magnetic island widths decrease to an unprecedented level, reducing the overlap of ...
|
||
|
Bidinosti C P - - 2004
Optical pumping of 3He produces large (hyper) nuclear-spin polarizations independent of the magnetic resonance imaging (MRI) field strength. This allows lung MRI to be performed at reduced fields with many associated benefits, such as lower tissue susceptibility gradients and decreased power absorption rates. Here we present results of 2D imaging ...
|
||
|
Roguin Ariel - - 2004
The magnetic field strength of both the magnet and gradient coils used in MR imaging equipment is measured in Tesla units, which are named for Nikola Tesla. This article presents the life and achievements of this Serbian-American inventor and researcher who discovered the rotating magnetic field, the basis of most ...
|
||
|
Adams Jack - - 2004
We evaluated wiring in multifamily developments containing National Electrical Code(R) (NEC(R)) violations as a source of unusual exposure to 60 Hz magnetic fields. Two methods were used in this evaluation: measurement and modeling. We measured the building wiring as a source of magnetic fields in six multifamily developments in Michigan. ...
|
||
|
Pan Hongjun - - 2004
Apparent biological effects of strong magnetic fields were observed in the hatching behavior of fresh mosquito eggs in the center of 9.4 and 14.1 T magnets. In the first experiment performed at 20 +/- 1 degrees C, the hatching was delayed 32 h by a 9.4 T magnetic field and ...
|
||
|
Grimm Jan - - 2004
Elevated telomerase levels are found in many malignancies, offering an attractive target for therapeutic intervention and diagnostic or prognostic purposes. Here we describe the use of a novel nanosensor developed for rapid screens of telomerase activity in biological samples. The technique utilizes magnetic nanoparticles that, on annealing with telomerase synthesized ...
|
||
|
Iacob Gh - - 2004
The in vivo targeting of tumors with magnetic microspheres is currently realized through the application of external non-uniform magnetic fields generated by rare-earth permanent magnets or electromagnets. Our theoretical work suggests a feasible procedure for local delivery of magnetic nano- and microparticles to a target area. In particular, thin magnetizable ...
|
||
|
Hu Xiaoping - - 2004
Among advances in magnetic resonance imaging (MRI), the increase of the magnetic field strength is perhaps one of the most significant. The use of high magnetic fields for in vivo magnetic resonance is motivated by a number of considerations. Advantages are increases in signal-to-noise ratio, blood-oxygenation level-dependent contrast, and spectral ...
|
||
|
Nimsky C - - 2004
Our concept of computer assisted surgery is based on the combination of intraoperative magnetic resonance (MR) imaging with microscope-based neuronavigation, providing anatomical and functional guidance simultaneously. Intraoperative imaging evaluates the extent of a resection, while the additional use of functional neuronavigation, which displays the position of eloquent brain areas in ...
|
||
|
Slavkovsky P - - 2004
Imaging of human internal organs by exact and non-invasive methods is very important for medical diagnosis, treatment and follow-up. 2003 Nobel Laureates in Physiology or Medicine have made original discoveries in the use of magnetic resonance to visualize different structures. Their discoveries have led to the development of modern magnetic ...
|
||
|
Malmivuo Jaakko A - - 2004
This lecture gives a general overview to the relationship of bioelectric and biomagnetic phenomena: The most important issue in bioelectromagnetism is: Are the biomagnetic measurements independent on bioelectric ones and do they bring new information from the source or are they only a different modality of the same phenomenon? This ...
|
||
|
Hatada Tomohisa - - 2004
Detection of weak magnetic fields induced by neuronal electrical activities with magnetic resonance imaging (MRI) is a potentially effective method for functional imaging of the brain. In this study, we compared the theoretical and practical limits of sensitivity for detecting weak magnetic fields with a columnar phantom. The theoretical limit ...
|
||
|
Yang Jie - - 2004
This focused review summarizes certain aspects of recent developments in the use of atomic force microscope in high-resolution imaging of membrane-bound biological macromolecules and in molecular force probing of the interaction between biological conjugates. We point out the pros and cons in these approaches and critically analyze details involved in ...
|
||
| < 10 11 12 13 14 15 16 17 18 19 20 > | ||