| Results 451 - 500 of 1388 | ||
| < 5 6 7 8 9 10 11 12 13 14 15 > | ||
|
Anninos P - - 2007
A 34-year-old male diagnosed of an intracranial arachnoid cyst arising in the left-sided temporal-parietal area, by computed tomography (CT), underwent evaluation by means of MEG. Biomagnetic waveform recordings were obtained from the target area and the Fourier analysis of these measurements was carried out. External magnetic stimulation in the order ...
|
||
|
Yrjänä S K - - 2007
Intraoperatively magnetic resonance (MR)-guided neurosurgical operations have been done since 1996, mostly for brain tumors. Several different concepts for intraoperative MRI procedures using low-, middle-, and high-field MR scanners have been reported from pioneering neurosurgical centers. In this article, we present the different solutions used in these centers from a ...
|
||
|
Wang Yucong - - 2007
Fritless packed beds comprised of magnetically responsive octadecylsilane bonded silica particles have been constructed for reversed-phase electrochromatography. The magnetic particles were immobilized in the capillary by applying an external magnetic field transverse to the direction of electroosmotic flow. Being subjected to the interplay of fluid dragging and magnetic forces, the ...
|
||
|
Houpt Thomas A - - 2007
High strength static magnetic fields are thought to be benign and largely undetectable by mammals. As magnetic resonance imaging (MRI) machines increase in strength, however, potential aversive effects may become clinically relevant. Here we report that rats find entry into a 14.1 T magnet aversive, and that they can detect ...
|
||
|
Zavaliche F - - 2007
We demonstrate the room-temperature control of magnetization reversal with an electric field in an epitaxial nanostructure consisting of ferrimagnetic nanopillars embedded in a ferroelectric matrix. This was achieved by combining a weak, uniform magnetic field with the switching electric field to selectively switch pillars with only one magnetic configuration. On ...
|
||
|
Morris Cassandra E - - 2007
Magnetic field therapy has recently become a widely used complementary/alternative medicine for the treatment of vascular, as well as other musculoskeletal pathologies, including soft tissue injuries. Recent studies in our laboratory and others have suggested that acute static magnetic field (SMF) exposure can have a modulatory influence on the microvasculature, ...
|
||
|
Sun L T - - 2007
Two high magnetic field hexapoles for electron cyclotron resonance ion source (ECRIS) have successfully fabricated to provide sufficient radial magnetic confinement to the ECR plasma. The highest magnetic field at the inner pole tip of one of the magnets exceeds 1.5 T, with the inner diameter (i.d.)=74 mm. The other ...
|
||
|
Eshed Iris - - 2008
OBJECTIVE: To compare MRI evaluation of a painful hindfoot of patients with spondyloarthritides (SpA) on low-field (0.2 T) versus high-field (1.5 T) MRI. MATERIALS AND METHODS: Patients with SpA and hindfoot pain were randomly referred to either high-field or low-field MRI. Twenty-seven patients were evaluated (male/female: 17:10; mean age: 39+/-1.4 ...
|
||
|
Peters Andrew M - - 2007
Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay ...
|
||
|
Han X F - - 2007
We report a time-resolved imaging study of the influence of shape on magnetic instabilities in patterned magnetic structures. We find that in rectangular structures magnetization reversal initiates at the ends and interior simultaneously, while in structures with tapered ends the reversal begins in the middle of the structures and spreads ...
|
||
|
Büchler Philippe - - 2007
The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An ...
|
||
|
Ladd Mark E - - 2007
OBJECTIVE: To expatiate on the possible advantages and disadvantages of high magnetic field strengths for magnetic resonance imaging and, in particular, for magnetic resonance angiography. METHODS AND RESULTS: A review of the available literature is given, presenting many of the advantages and disadvantages of imaging at higher field strengths. Focus ...
|
||
|
Schwenzer Nina F - - 2007
OBJECTIVES: We investigated the influence of magnetic resonance (MR) at 3.0 T on clonogenic ability, proliferation, and cell cycle in an embryonic human cell line. MATERIALS AND METHODS: Cells (human lung fibroblasts Hel 299) were exposed to the static magnetic field (3.0 T) of a magnetic resonance imager (MRI) and ...
|
||
|
Bird Paul - - 2007
The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist and metacarpophalangeal joints was to assess the intermachine (high vs ...
|
||
|
Chen Haitao - - 2008
High gradient magnetic separation (HGMS) of magnetic materials from fluids or waste products has many established industrial applications. However, there is currently no technology employing HGMS for ex-vivo biomedical applications, such as for the removal of magnetic drug- or toxin-loaded spheres from the human blood stream. Importantly, human HGMS applications ...
|
||
|
Iunin Y L - - 2007
We report unexpected phenomena during magnetization reversal in ultrathin Co films and Co/Pt multilayers with perpendicular anisotropy. Using magneto-optical Kerr microscopy and magnetic force microscopy we have observed asymmetrical nucleation centers where the reversal begins for one direction of the field only and is characterized by an acute asymmetry of ...
|
||
|
Hashizume Akira - - 2007
We developed gradient magnetic-field topography (GMFT) for magnetoencephalography (MEG). We plotted the Euclidean norms of gradient magnetic fields occurring at the centers of 102 sensors onto 49-point grids and projected these norms onto the MRI brain surface of a 12-year-old boy who presented with neocortical epilepsy secondary to a left ...
|
||
|
Jaensch M - - 2007
An experiment to show that a magnetic resonance imaging (MRI) magnet could be assembled around a patient, and used as part of a prepolarization system in which substantial transient forces are applied to parts of it, is described. The paper describes the circumstances that develop as a result of the ...
|
||
|
Sirmatel Ocal - - 2007
This study was carried out in order to determine nitric oxide (NO) production immediately after a 1.5 T magnetic field 30 min exposure to an experimental group, comprising 33 healthy young male volunteers aged 18-26 years old. In addition, a control group, comprising 30 healthy male volunteers aged 19-26 years ...
|
||
|
Age-specific impairment of morris water maze performance following neonatal exposure to magnetic ...
Yang Lin - - 2007
To investigate the effects of magnetic resonance image (MRI) exposure on CNS development, we examined the effects of neonatal exposure of rats to a MRI magnetic field on their performance in the Morris water maze. After birth, all litters were randomly divided into an MRI-scanning group (experimental group) comprised of ...
|
||
|
Witschey Walter R T WR - - 2007
The origin of spin locking image artifacts in the presence of B(0) and B(1) magnetic field imperfections is shown theoretically using the Bloch equations and experimentally at low (omega(1) << Delta omega(0)), intermediate (omega(1) approximately Delta omega(0)) and high (omega(1) >> Delta omega(0)) spin locking field strengths. At low spin ...
|
||
|
You Xiaogang - - 2007
In this study, hydrophilic high-luminescent magnetic nanocomposites (LMNCs) composed of both fluorescent clusters (quantum dots, QDs) and magnetic nanoparticles were synthesized. The nanocomposites exhibited high luminescence and were easily separated in an external magnetic field. The LMNCs were capped with streptavidin (SA), and the SA on the surface of LMNC-SA ...
|
||
|
Shellock Frank G - - 2007
A magnetically programmable cerebrospinal fluid (CSF) shunt valve (Codman Hakim Programmable Valve, Codman, a Johnson & Johnson Company, Raynham, MA) was assessed for magnetic field interactions, heating, artifacts and functional changes at 3-Tesla. The programmable valve showed minor magnetic field interactions and heating (+0.4 degrees C). Artifacts were relatively large ...
|
||
|
Farrher German - - 2007
The spatial distribution of the liquid phase in a typical, partially filled, porous glass (VitraPor #5) has been examined with the aid of magnetic resonance microscopy and field gradient nuclear magnetic resonance diffusometry techniques. The correlation length of the material turned out to be long enough to permit the visualization ...
|
||
|
Calculation of static and dynamic linear magnetic response in approximate time-dependent density ...
Krykunov Mykhaylo - - 2007
We report implementations and results of time-dependent density functional calculations (i) of the frequency-dependent magnetic dipole-magnetic dipole polarizability, (ii) of the (observable) translationally invariant linear magnetic response, and (iii) of a linear intensity differential (LID) which includes the dynamic dipole magnetizability. The density functional calculations utilized density fitting. For achieving ...
|
||
|
Perlo Juan - - 2007
Portable single-sided nuclear magnetic resonance (NMR) magnets used for nondestructive studies of large samples are believed to generate inherently inhomogeneous magnetic fields. We demonstrated experimentally that the field of an open magnet can be shimmed to high homogeneity in a large volume external to the sensor. This technique allowed us ...
|
||
|
Park Tae Seok - - 2007
Whether the neuronal magnetic fields (NMFs) could cause measurable MRI signal changes in the human brain seems to be still controversial. In this study, we have numerically investigated the NMF effects on the MRI signal using two separate current source models for axons and dendrites. Since intracellular current distributions are ...
|
||
|
Cruickshank Paul A S - - 2007
Force detected electron spin resonance (FDESR) detects the presence of unpaired electrons in a sample by measuring the change in force on a mechanical resonator as the magnetization of the sample is modulated under magnetic resonance conditions. The magnetization is coupled to the resonator via a magnetic field gradient. It ...
|
||
|
Boybay Muhammed S - - 2007
The realization of double negative (DNG) meta-materials and the evanescent field amplification feature of these materials engendered new approaches to subwavelength imaging. In this paper, we study the possibility of subsurface detection using evanescent fields in the presence of a DNG lens. Evanescent fields at lower frequencies can have better ...
|
||
|
Florin E - - 2007
A magnetic guidance methodology to rotate a device around the catheter axis is proposed. The specific medical application is to intracranial aneurysms. An endovascular device, the asymmetric stent, has a low porosity region that is rotated to cover the aneurysm neck so as to reduce the blood flow into and ...
|
||
|
Cheong Sang-Wook - - 2007
Magnetism and ferroelectricity are essential to many forms of current technology, and the quest for multiferroic materials, where these two phenomena are intimately coupled, is of great technological and fundamental importance. Ferroelectricity and magnetism tend to be mutually exclusive and interact weakly with each other when they coexist. The exciting ...
|
||
|
Paixão Fabiano C - - 2007
Anisotropic Magnetoresistive (AMR) sensors shows a new possibility to detect magnetic fields produced by magnetic particles present in the gastrointestinal (GI) tract. A system that uses excitation and detection of magnetic field was developed using AMR sensor. A magnetic flux concentrator was also studied to increase the sensitivity of AMR ...
|
||
|
Wang H - - 2007
In modern magnetic resonance imaging (MRI), there are concerns for the health and safety of patients and workers repeatedly exposed to magnetic fields, and therefore accurate and efficient evaluation of in situ electromagnetic field (EMF) distributions has gained a lot of significance. This paper presents a Biconjugate Gradient Method (BiCG) ...
|
||
|
Azmi Hooman - - 2007
OBJECTIVE: We previously demonstrated the capability to obtain functional magnetic resonance imaging (MRI) scans of the motor cortex in healthy volunteers using a low-field mobile operating room-based MRI scanner with 0.12-T field strength. Using an expanded (0.15-T), but still mobile, version of this system, our goal was to acquire data ...
|
||
|
Placidi G - - 2007
Endovascular catheterisation is performed by an interventional radiologist using fluoroscopic guide and contrast-media. The X-Ray exposure both of the patient and of the operators can induce heavy collateral effects. The present paper describes an innovative magnetic position/orientation indicator capable to drive the endovascular probe during in-vivo medical diagnostic or interventional ...
|
||
|
Huo Xueliang - - 2007
We have developed an enhanced prototype of the new Tongue Drive system (TDS), which is a noninvasive, unobtrusive wireless magnetic tongue-computer interface for people with severe disabilities. A small permanent magnet secured on the tongue using tissue adhesives, implantation, or piercing is utilized as a tracer to track tongue movements. ...
|
||
|
Lippert Julia F - - 2007
Nondestructive testing is any technique used to inspect the integrity of a manufactured item without diminishing its future usefulness. Magnetic particle inspection is one type of nondestructive testing that uses electromagnetism in the inspection procedure, thus potentially exposing the operator to magnetic fields. During magnetic particle inspection, investigators took peak ...
|
||
|
Calota Violeta - - 2007
The purpose of this article is to evaluate magnetic field effects (50 Hz, different magnetic intensities) on the chemiluminescence intensity of human serum. We find that 1 and 2 h of exposure increased the chemiluminescence emission. The addition to the serum of prooxidants FeCl(2) and H(2)O(2) in different concentrations increased ...
|
||
|
Kumar Santhosh T A - - 2007
Electron beam wire tomography in the H-1NF heliac enables high resolution mapping of vacuum flux surfaces with minimal disruption of the plasma operations schedule. Recent experimental results have proven this technique to be a highly accurate and high resolution method for mapping vacuum magnetic islands. Islands of width as small ...
|
||
|
Shellock Frank G - - 2007
RATIONALE AND OBJECTIVES: To evaluate the effect of Magnetic Resonance Imaging (MRI) performed at 1.5-Tesla on current generation pacemakers and ICDs to identify safe parameters for MRI examinations. METHODS: Pacemakers (Identity ADx XL DR+ 5386 and Identity ADx DR + 5380 generators; 1688T/52-cm atrial and ventricular leads) and ICDs (Atlas ...
|
||
|
Costa Roberta Martins da Silva - - 2007
PURPOSE: To report the unusual visual field finding due to a chiasmal neuritis in a 33-year-old female with the diagnosis of optic neuromyelitis optica (Devic's syndrome). METHODS: We report a case of a 33 years old female with limb paraesthesias, weakness in the legs, bowel and bladder dysfunction that was ...
|
||
|
Clarke John - - 2007
The use of very low noise magnetometers based on Superconducting QUantum Interference Devices (SQUIDs) enables nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) in microtesla magnetic fields. An untuned superconducting flux transformer coupled to a SQUID achieves a magnetic field noise of 10(-15) T Hz(-1/2). The frequency-independent response of ...
|
||
|
Imaged deconvolution: a method for extracting high-resolution NMR spectra from inhomogeneous fields.
Halse Meghan E - - 2007
We present a novel method for obtaining high resolution NMR spectra in the presence of grossly inhomogeneous magnetic fields, such as those encountered in one-sided access NMR. Our method combines the well-known principle of reference deconvolution with NMR imaging in order to resolve spectral features with frequency resolution orders of ...
|
||
|
Wei Ning - - 2007
A new-type in situ probe has been developed to acquire dark field images of yeast in bioreactors. It has been derived from an in situ bright field microscope that is able to measure cell density in bioreactors during fermentation processes. The illumination part of the probe has been replaced with ...
|
||
|
Paniagua Jesús M - - 2007
Magnetic field levels were studied in an urban area--the city of Cáceres (Spain). The study included systematic spot measurements throughout the city, an analysis of the temporal variation of the magnetic field, and the incorporation of the data into a geographic information system. The levels detected were at most 7.3% ...
|
||
|
Levin Yan - - 2006
Motivated by a beautiful demonstration of the Faraday and the Lenz laws in which a small neodymium magnet falls slowly through a conducting nonferromagnetic tube, we consider the dynamics of a magnet falling coaxially through a superconducting pipe. Unlike the case of normal conducting pipes, in which the magnet quickly ...
|
||
|
Huang Susie Y - - 2006
OBJECTIVE: Nonlinear feedback interactions induced by the spins themselves have recently been introduced as novel MRI contrast enhancement mechanisms sensitive to small differences in MR parameters. Developing feedback-based contrast enhancement into a useful tool for in vivo imaging requires improved techniques that are robust to inhomogeneity and sensitive to subtle ...
|
||
|
Voskoboynik Pavel - - 2006
Positive-intrinsic-negative (PIN) silicon diodes are commonly used in magnetic resonance imaging (MRI) coils to perform active or passive blocking and detuning, or to disable circuit functions. However, diode packages with large magnetic moments are known to cause image artifacts in high field MRI systems. In this study, diode packages with ...
|
||
|
van der Bogt Koen E A - - 2006
Human embryonic stem cells (hESCs) are capable of differentiation into every cell type of the human being. They are under extensive investigation for their regenerative potential in a variety of debilitating diseases. However, the field of hESC research is still in its infancy, as there are several critical issues that ...
|
||
|
Fritsch Michael H - - 2006
HYPOTHESIS: A 9.4-T magnetic resonance (MR) field may cause motion displacement of the middle ear and stapes implants not previously observed with 1.5- and 3.0-T magnets. BACKGROUND: Publications have described the safety limitations of some otologic implants in 4.7-T field and resulted in several companywide patient safety-related recalls. To date, ...
|
||
| < 5 6 7 8 9 10 11 12 13 14 15 > | ||