Chen Zhijin - - 2010
A nanoparticle magnetic resonance imaging (MRI) contrast agent targeted to liver was developed by conjugation of gadolinium (Gd) chelate groups onto the biocompatible poly(l-lactide)-block-poly (ethylene glycol) (PLA-PEG) nanoparticles. PLA-PEG conjugated with diethylenetriaminopentaacetic acid (DTPA) was used to formulate PLA-PEG-DTPA nanoparticles by solvent diffusion method, and then Gd was loaded onto ...
|
||
|
Li Xia - - 2011
In permanent magnetic resonance imaging (MRI) systems, pulsed gradient fields induce strong eddy currents in the conducting structures of the magnet body. The gradient field for image encoding is perturbed by these eddy currents leading to MR image distortions. This paper presents a comprehensive finite element (FE) analysis of the ...
|
||
|
Optically detunable, inductively coupled coil for self-gating in small animal magnetic resonance ...
Korn Matthias - - 2011
An inductively coupled coil concept is presented, which improves the compensation of physiological motion by the self-gating (SG) technique. The animal is positioned in a conventional volume coil encompassing the whole animal. A small, resonant surface coil (SG-coil) is placed on the thorax so that its sensitive region includes the ...
|
||
|
Optically detunable, inductively coupled coil for self-gating in small animal magnetic resonance ...
Korn Matthias - - 2010
An inductively coupled coil concept is presented, which improves the compensation of physiological motion by the self-gating (SG) technique. The animal is positioned in a conventional volume coil encompassing the whole animal. A small, resonant surface coil (SG-coil) is placed on the thorax so that its sensitive region includes the ...
|
||
|
van Elderen Saskia G C - - 2010
To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, ...
|
||
|
Li Shizhe - - 2010
Previously, we devised a novel strategy for in vivo 13C MRS using [2-13C]glucose infusion and low-power proton decoupling, and proposed that this strategy could be used to acquire 13C MR spectra from the frontal lobe of the human brain. Here, we demonstrate, for the first time, in vivo 13C MRS ...
|
||
|
Qiu S S - - 2010
Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic ...
|
||
|
Chen Shu-Fang - - 2010
The magnetic and magneto-transport properties of Ni nanowire (NW) arrays, fabricated by electrodeposition in anodic-aluminum-oxide (AAO) templates, have been investigated. The AAO pores have diameters ranging from 35 to 75 nm, and the crystallinity of the Ni NW arrays could change from poly-crystalline to single-crystalline with the [111] and [110] ...
|
||
|
Kang Chang-Ki - - 2010
To visualize the perforating arteries originating from basilar artery (BA) by using ultra-high resolution 7T MR angiography (MRA) and optimizing MR parameters as well as radio frequency (RF) coils, which may provide important information for neurosurgery and understanding diseases of the pons, but was unable to clearly visualize with conventional ...
|
||
|
Trerotola Scott O - - 2010
OBJECTIVE: Recanalization has been reported with the use of a type 1 Amplatzer vascular plug as the sole device to manage a pulmonary arteriovenous malformation (PAVM). We evaluated our experience with the use of at least one coil in addition to the vascular plug whenever possible in the treatment of ...
|
||
|
Umutlu Lale - - 2010
RATIONALE AND OBJECTIVES: The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. MATERIAL AND METHODS: A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using ...
|
||
|
Lee Seung Hwan - - 2010
The goal of this study was to compare the diagnostic use and safety of endorectal coil (ERC) MRI with those of phased-array coil MRI. We retrospectively included 91 consecutive patients who had undergone 1.5-T MRI with ERC or with phased-array coil MRI before radical prostatectomy at our institution. We compared ...
|
||
|
Lanz Titus - - 2010
Murine MRI studies are conducted on dedicated MR systems, typically equipped with ultra-high-field magnets (>or=4.7 T; bore size: approximately 12-25 cm), using a single transmit-receive coil (volume or surface coil in linear or quadrature mode) or a transmit-receive coil combination. Here, we report on the design and characterization of an ...
|
||
|
Sharma Rakesh - - 2010
Ex vivo magnetic resonance microimaging (MRM) image characteristics are reported in human skin samples in different age groups. Human excised skin samples were imaged using a custom coil placed inside a 500 MHz NMR imager for high-resolution microimaging. Skin MRI images were processed for characterization of different skin structures. Contiguous ...
|
||
|
Griffith James F - - 2010
Osteochondral lesion (OCL) treatment is based on patient symptoms, lesion size, and lesion stability. MRI of talar OCL identifies the presence and the characteristics of the lesion and attempts to establish lesion stability. We report our experience that the depiction of OCL can be improved by using a small field-of-view ...
|
||
|
Zhang Xiaoli - - 2010
MR microscopy is being explored as a useful imaging tool to phenotype mouse embryos due to its volume coverage with three-dimensional isotropic resolution. However, the main limitation for mouse embryo MR microscopy is the signal-to-noise ratio. Large numbers of embryos are needed for phenotypic screening, making high throughput essential. Two ...
|
||
|
Adriany Gregor - - 2010
Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imaging performance and SNR. Concentric coil ...
|
||
|
Dudding Nick - - 2011
Rapid prescreening (RPS) is a powerful tool to measure and improve performance in the cytology laboratory. Long-term use of RPS has been shown to result in improved sensitivity and precision in routine screening. The effect of long-term RPS on RPS itself is not known. We compared the sensitivity of 100% ...
|
||
|
Chang Gregory - - 2010
Ultra-high field (UHF; >or=7 T) magnetic resonance imaging (MRI), with its greater signal-to-noise ratio, offers the potential for increased spatial resolution, faster scanning, and, above all, improved biochemical and physiological imaging of skeletal muscle. The increased spectral resolution and greater sensitivity to low-gamma nuclei available at UHF should allow techniques ...
|
||
|
Wong Alexander - - 2011
An important postprocessing step for MR data is noise reduction. Noise in MR data is difficult to suppress due to its signal-dependence. To address this issue, a novel stochastic approach to noise reduction for MR data is presented. The estimation of the noise-free signal is formulated as a general Bayesian ...
|
||
|
Mathieu Jean-Baptiste - - 2010
Upgraded gradient coils can effectively enhance the MRI steering of magnetic microparticles in a branching channel. Applications of this method include MRI targeting of magnetic embolization agents for oncologic therapy. A magnetic suspension of Fe(3)O(4) magnetic particles was injected inside a y-shaped microfluidic channel. Magnetic gradients of 0, 50, 100, ...
|
||
|
Ha Seunghoon - - 2010
Magnetic resonance (MR)-based multimodality imaging systems, such as single-photon emission tomography (SPECT)/magnetic resonance imaging (MRI) or positron emission tomography (PET)/MRI, face many difficulties because of problems with the compatibility of the nuclear detector system with the MR system. However, several studies have reported on the design considerations of MR-compatible nuclear ...
|
||
|
Szewczyk Paweł - - 2010
Pathological examinations and the increasingly popular diffusion tensor imaging (DTI) show that in Alzheimer's disease (AD), the pathology involves not only the cortical and hippocampal structures, but also the white matter of the brain. DTI is a well recognized technique for evaluation of the integrity of white matter fibers. The ...
|
||
|
Legl S - - 2010
We report the development of a vibrating coil magnetometer (VCM) as combined with a top-loading dilution refrigerator for measurements of the magnetization down to millikelvin temperatures. The VCM offers unique measurement conditions, notably efficient cooling of the sample, data collection in uniform magnetic fields, the possibility to study strong magnetic ...
|
||
|
Lew Calvin - - 2010
To compare generalized autocalibrating partially parallel acquisitions (GRAPPA), modified sensitivity encoding (mSENSE), and SENSE in phase-contrast magnetic resonance imaging (PC-MRI) applications. Aliasing of the torso can occur in PC-MRI applications. If the data are further undersampled for parallel imaging, SENSE can be problematic in correctly unaliasing signals due to coil ...
|
||
|
Qian Di - - 2010
The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. ...
|
||
|
Ramirez Marc S - - 2010
Compared to traditional single-animal imaging methods, multiple-mouse MRI has been shown to dramatically improve imaging throughput and reduce the potentially prohibitive cost for instrument access. To date, up to a single radiofrequency coil has been dedicated to each animal being simultaneously scanned, thus limiting the sensitivity, flexibility, and ultimate throughput. ...
|
||
|
Webb Andrew G - - 2010
Using a small resonant loop to produce a longitudinal traveling wave on a human 7-T system allows MR to be performed over the entire volume of the human leg. We have used this capability to perform localized proton MR spectroscopy of the lipid composition of muscle in volunteers with a ...
|
||
|
Ha Yong H - - 2010
We introduce a square coil system for remote magnetic navigation of a magnetic device without any physical movements of the coils. We used three square-Helmholtz coils and a square-Maxwell coil for magnetic propulsion of a small magnet along the desired path. All the square coils are mountable on a cubic ...
|
||
|
Gorny Krzysztof R - - 2010
PURPOSE: To assess safety of clinical MRI of the head in patients with implanted model 100, 102, and 103 vagus nerve stimulation (VNS) Therapy Systems (Cyberonics, Inc., Houston, TX) in 3.0 Tesla MRI (GE Healthcare, Milwaukee, WI). MATERIALS AND METHODS: The distributions of the radiofrequency B(1) (+)-field produced by the ...
|
||
|
Mager Dario - - 2010
Inkjet printing has been used to produce resonant radio frequency coils that are comparable to those produced by conventional printed circuit board (PCB) methods. The coils, which consist of a conductive loop and in-series capacitors, form part of a receiver circuit that is used for magnetic resonance imaging (MRI). The ...
|
||
|
Burke B - - 2010
The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time ...
|
||
|
Jeong Sang Young - - 2010
Biocompatible poly-[N-(2-hydroxyethyl)-d,l-aspartamide]-methoxypoly(ethyleneglycol)-hexadecylamine (PHEA-mPEG-C(16)) conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd) via ethylenediamine (ED) was synthesized as a magnetic resonance imaging (MRI) contrast agent. Amphiphilic PHEA-mPEG-C(16)-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance ((1)H NMR). Micelle size and shape were examined by dynamic light ...
|
||
|
Constantinides C - - 2010
The idea of a novel MR surface coil based on multi-turn spiral geometry is presented for use in mouse cardiac MRI. The benefits from flat, cylindrical arrangement of the coil are compared using computer simulations and MRI experiments in various cases of free space, phantom and animal loading conditions. Results ...
|
||
|
Asfour Aktham - - 2010
We present in this paper a dedicated home-built RF probe-head for the MRI of rat brain at 2.35 T. This probe consists of an association of three coils: a double-tuned birdcage coil, which could be used for both transmitting and receiving, and a single-tuned surface coil that is used for ...
|
||
|
He Bo - - 2010
The recent development of 1D barcode arrays has proved their capabilities to be applicable to highly multiplexed bioassays. This article introduces two magnetic decoding protocols for suspension arrays of shape-coded silica nanotubes to process multiplexed assays rapidly and easily, which will benefit the minimization and automation of the arrays. In ...
|
||
|
Lee Ray F - - 2010
One of the major functions of the human brain is to mediate interactions with other people. Until recently, studying brain social interactions has not been possible due to the lack of measurable methods to observe two interacting minds simultaneously. We have developed a novel dual-head MRI coil that can scan ...
|
||
|
Martini N - - 2010
The acquisition of magnetic resonance spectroscopy (MRS) signals by multiple receiver coils can improve the signal-to-noise ratio (SNR) or alternatively can reduce the scan time maintaining a reliable SNR. However, using phased array coils in MRS studies requires efficient data processing and data combination techniques in order to exploit the ...
|
||
|
Gongidi Preetam - - 2010
Gout is a systemic, metabolic disease that typically affects the peripheral joints. We describe an unusual presentation of gout affecting the facet joints and costovertebral joints in the thoracic and lumbar spine. A 54-year old man presents to the emergency department with increasing swelling and pain at the left elbow ...
|
||
|
Solis S E - - 2010
The effect of the shielding in a PET-MRI system was numerically estimated by calculating the RF magnetic field, B1, produced by a coil array of 4 independent elements at the resonant frequency of 171 MHz (4T for protons). The array coil is located inside a μPET camera to simultaneously acquire ...
|
||
|
Schuck A - - 2010
A new class of wavelet functions called data-based autocorrelation wavelets is developed for analyzing Magnetic Resonance Spectroscopic (MRS) signals by means of the continuous wavelet transform (CWT), instead of the traditional wavelet like Morlet wavelet. These new wavelets are derived from the normalized autocorrelation function from metabolite data and then ...
|
||
|
Kickler Nils - - 2010
Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. In ...
|
||
|
Takahara Taro - - 2010
OBJECTIVE: To introduce and assess a new way of performing whole-body magnetic resonance imaging (MRI) using a non-integrated surface coil approach as available on most clinical MRI systems worldwide. METHODS: Ten consecutive asymptomatic subjects prospectively underwent whole-body MRI for health screening. Whole-body MRI included T1-, T2- and diffusion-weighted sequences, and ...
|
||
|
Gilbert Guillaume - - 2009
RATIONALE AND OBJECTIVES: To investigate the ability of an intravascular magnetic resonance (MR) loopless antenna to reduce the radiofrequency shielding of a vascular stent during signal reception as a way to improve the visualization of the in-stent lumen. METHODS AND MATERIALS: Using a balanced steady-state free-precession (bSSFP) sequence and a ...
|
||
|
Rengle Adrian - - 2009
In the field of small animal studies, the array coil imaging has become increasingly important. In this paper, a dedicated two-channel array coil operating at 300 MHz (7 T) for high-resolution MRI (HR-MRI) of the rat knee cartilage is presented. The average gain in signal-to-noise ratio (SNR) compared to a ...
|
||
|
Hayes Cecil E - - 2009
The author gives a personal account of the development of the birdcage resonator while he worked at GE Medical Systems. The emphasis is on promoting an intuitive understanding of the underlying principles of RF coil design by recounting the assumptions, misconceptions, and reasoning involved in addressing the challenging problems in ...
|
||
|
Neuberger Thomas - - 2009
Given the several orders of magnitude fewer spins per voxel for MR microscopy than for conventional MRI, efficient coil design is important to obtain sufficient signal-to-noise within reasonable data acquisition times. As MR microscopy is typically performed using very high magnetic fields, coil design must also incorporate the effects of ...
|
||
|
Uecker Martin - - 2009
Each k-space segment in multishot diffusion-weighted MRI is affected by a different spatially varying phase which is caused by unavoidable motions and amplified by the diffusion-encoding gradients. A proper image reconstruction therefore requires phase maps for each segment. Such maps are commonly derived from two-dimensional navigators at relatively low resolution ...
|
||
|
Sim Jae Hoon - - 2009
The inability to identify 3-D force and moment components for actuators and sensors is a major limiting factor in the study of 3-D force interactions with small-scale biological structures. While recent advances have been made in the measurement of stimulating forces using load cells and atomic-force microscopy in experimental preparations ...
|
||
|
Wu Bing - - 2010
The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to ...
|
||