Search Results
Results 451 - 500 of 1607
< 5 6 7 8 9 10 11 12 13 14 15 >
Simon Edmund - - 2009
To improve the objectivity of the integration of positron emission tomography (PET), we used the conformality index (CI) to measure the goodness of fit of a given PET iso-SUV (standardized uptake value) level with the GTV defined on PET (GTV(PET)) and CT (GTV(CT)). Twenty-two datasets involving 20 head and neck ...
Risse J??rn H - - 2009
The diagnostic accuracy of 18F-FDG-PET (fluoro-2-deoxyglucose-positron emission tomography) remains questionable for primary hepatocellular carcinoma (HCC) but seems to be more promising for restaging and therapy control. Yet, there are no data on FDG-PET in 131I-lipiodol treatment for primary liver cancer. The aim of this study was to relate baseline FDG-PET ...
Neeb Daniel - - 2009
Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass ...
Gao Zhen-Hua - - 2009
Objective:  To discuss imaging features of radiographs, computed tomography (CT), magnetic resonance imaging (MRI) and radionuclide imaging of the herniation pit of the femoral neck and their implications for pathogenesis. Methods:  Twenty-seven patients with 31 herniation pits of the femoral neck were analyzed. All patients were examined by plain radiographs, ...
Fiebrich Helle-Brit - - 2009
CONTEXT: Catecholamine excess is rare, but symptoms may be life threatening. OBJECTIVE: The objective of the study was to investigate the sensitivity of 6-[F-18]fluoro-l-dihydroxyphenylalanine positron emission tomography ((18)F-DOPA PET), compared with (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy and computer tomography (CT)/magnetic resonance imaging (MRI) for tumor localization in patients with catecholamine excess. DESIGN ...
Stelter Lars - - 2010
PURPOSE: The aim of our study was to modify an aminosilane-coated superparamagnetic nanoparticle for cell labeling and subsequent multimodal imaging using magnetic resonance imaging (MRI), positron emission tomography (PET), and fluorescent imaging in vivo. PROCEDURES: We covalently bound the transfection agent HIV-1 tat, the fluorescent dye fluorescein isothiocyanate, and the ...
Avila Laura - - 2009
We present a case of a healthy 7-year-old female with an incidental finding of a growing splenic lesion, diagnosed as a splenic hamartoma after splenectomy. This case highlights the diagnostic challenge of splenic lesions and that the role of positron emission tomography/computerized tomography (PET/CT) in defining splenic lesions in the ...
Imaizumi Masao - - 2009
PURPOSE: We developed a new type of scintillation detector ring for positron emission tomography (PET). In this device the scintillation detectors were connected with 2.6 m length optic fibers to transport scintillation light to a photomultiplier (PMT) located apart from the detector rings. The present study aimed to test the ...
LeBlanc Amy K - - 2009
Positron emission tomography (PET) with 2-deoxy-2-[18sF]fluoro-D-glucose (18FDG) is an important imaging modality for diagnosis and staging of human neoplastic disease. The purpose of this study is to describe the normal is 18FDG uptake in adult cats. Six adult healthy female cats were used. Cats were sedated and then injected intravenously ...
Lee In Sook - - 2009
OBJECTIVE: The purpose of this study was to compare the effectiveness of positron emission tomography (PET)/computed tomography (CT) in distinguishing between tuberculous and pyogenic spondylitis with that of magnetic resonance imaging (MRI). METHODS: Twenty-two consecutive patients confirmed to have tuberculous or pyogenic spondylitis were examined with both MRI and dual-time ...
Zaidi Habib - - 2009
Multimodality molecular imaging using high resolution positron emission tomography (PET) combined with other modalities is now playing a pivotal role in basic and clinical research. The introduction of combined PET/CT systems in clinical setting has revolutionized the practice of diagnostic imaging. The complementarity between the intrinsically aligned anatomic (CT) and ...
Dandois V - - 2010
PURPOSE: Our aim was to compare perfusion magnetic resonance imaging (MRI) and positron emission tomography (PET) using carbon-11 labelled methionine (MET) in gliomas and their value in differentiating tumour recurrence from necrosis. MATERIALS AND METHODS: We retrospectively reviewed 28 patients with a high-grade glioma. A total of 33MR perfusions and ...
Bengel Frank M - - 2009
Positron emission tomography (PET) is a powerful, quantitative imaging modality that has been used for decades to noninvasively investigate cardiovascular biology and physiology. Due to limited availability, methodologic complexity, and high costs, it has long been seen as a research tool and as a reference method for validation of other ...
Knopf A - - 2009
The clinical use of offline positron emission tomography/computed tomography (PET/CT) scans for proton range verification is currently under investigation at the Massachusetts General Hospital (MGH). Validation is achieved by comparing measured activity distributions, acquired in patients after receiving one fraction of proton irradiation, with corresponding Monte Carlo (MC) simulated distributions. ...
Langah Rumman - - 2009
BACKGROUND: The Japanese Ministry of Health and Welfare guidelines (JMHWG) are currently the standard used to diagnose cardiac sarcoidosis. JMHWG incorporate (67)Gallium scintigraphy as a minor criterion, while fasting (18)fluorine-2-fluoro-2-deoxy-D-glucose (FDG) PET is not included. As there is no published data comparing the accuracy of prolonged fasting FDG PET-CT (PF-PET) ...
Chang Chih-Yung - - 2010
OBJECTIVES: The objective of this study was to evaluate the increased diagnostic benefit of integrated positron emission tomography/computed tomography (PET/CT) interpretation in evaluating solitary pulmonary nodules for malignancy. METHODS: One hundred seventeen patients (67 men and 50 women; mean age +/- SD, 61.7 +/- 13.6 years, range, 31-86 years) with ...
Sher D J - - 2009
BACKGROUND: Although positron emission tomography (PET) response to chemotherapy (CT) has prognostic significance in Hodgkin's lymphoma (HL), it is unclear whether patients with 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG)-PET positivity during and/or after CT can be rendered disease free with consolidative involved-field radiotherapy (IFRT). METHODS: Patients with HL treated with adriamycin, bleomycin, vinblastine and ...
Wu Yibao - - 2009
A dedicated breast PET/CT system has been constructed at our institution, with the goal of having increased spatial resolution and sensitivity compared to whole-body systems. The purpose of this work is to describe the design and the performance characteristics of the PET component of this device. Average spatial resolution of ...
Wu Yibao - - 2009
A magnetic resonance (MR) compatible positron emission tomography (PET) insert has been developed in our laboratory for simultaneous small animal PET/MR imaging. This system is based on lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiode (PSAPD) photodetectors. The PET performance of this insert has been measured. The average reconstructed ...
Scheuermann Joshua S - - 2009
The PET Core Laboratory of the American College of Radiology Imaging Network (ACRIN) qualifies sites to participate in multicenter research trials by quantitatively reviewing submitted PET scans of uniform cylinders to verify the accuracy of scanner standardized uptake value (SUV) calibration and qualitatively reviewing clinical PET images from each site. ...
Petermann David - - 2009
Preoperative imaging for resection of chest wall malignancies is generally performed by computed tomography (CT). We evaluated the role of (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in planning full-thickness chest wall resections for malignancies. We retrospectively included 18 consecutive patients operated from 2004 to 2006 at our institution. Tumor extent ...
Krüger Stefan - - 2009
PURPOSE: The aim of the study was to compare the diagnostic accuracy of (18)F-fluorodeoxyglucose (FDG) PET/CT versus standard planar bone scintigraphy (BS) and (18)F-labelled NaF ((18)F) PET for the detection of bone metastases (BM) in non-small cell lung cancer (NSCLC). METHODS: (18)F-FDG PET/CT was performed in 126 patients with NSCLC. ...
Hutchings Martin - - 2009
PET has become a cornerstone procedure in modern lymphoma management. This paper reviews, from a clinical point of view, the evidence for using PET in the different subtypes of lymphoma and the different steps of their management. The reader is given an overview of the current PET-based interventional lymphoma trials ...
Desouza R M - - 2009
Positron emission tomography-computed tomography (PET-CT) is a useful imaging method for localizing infective lesions. We report a case of autosomal dominant polycystic kidney disease in which PET-CT was used to differentiate between infection in the kidney and liver cysts. Localization of infection to the liver rather than to kidney cysts ...
Song Won S - - 2009
OBJECTIVE: The goal of this study was to determine normal standard uptake values of carbon-11 (11C) acetate in healthy organs. By accurately determining the range of physiologic activity, abnormal focal or diffuse 11C-acetate activity can be more accurately assessed and thus improve the sensitivity and specificity of this emerging diagnostic ...
Halpenny Darragh F - - 2009
BACKGROUND: Positron emission tomography (PET) is a nuclear imaging technique providing noninvasive, three-dimensional, whole-body, quantitative images. The primary use of PET is in tumor detection and staging. More recently, it has been shown to be of value in assessing patients with inflammatory processes. To date the role of PET in ...
Fouquet Marine - - 2009
A sensitive marker for monitoring progression of early Alzheimer's disease would help to develop and test new therapeutic strategies. The present study is aimed at investigating brain metabolism changes over time, as a potential monitoring marker, in patients with amnestic mild cognitive impairment, according to their clinical outcome (converters or ...
Lei Peng - - 2010
This study evaluates the accuracy of augmenting initial intraprocedural computed tomography (CT) during radiofrequency ablation (RFA) of hepatic metastases with preprocedural positron emission tomography (PET) through a hardware-accelerated implementation of an automatic nonrigid PET-CT registration algorithm. The feasibility of augmenting intraprocedural CT with preprocedural PET to improve localization of CT-invisible ...
Zaro-Weber Olivier - - 2009
BACKGROUND AND PURPOSE: Perfusion-weighted MRI-based maps of cerebral blood flow (CBF(MRI)) are considered a good MRI measure of penumbral flow in acute ischemic stroke but are seldom used in clinical routine due to methodical issues. We validated CBF(MRI) on quantitative CBF measurement by 15O-water positron emission tomography (CBF(PET)). Material and ...
Krajicek Bryan J - - 2009
BACKGROUND: Pulmonary Langerhans cell histiocytosis (PLCH) is an inflammatory lung disease strongly associated with cigarette smoking and an increased risk of malignant neoplasms. Although the chest CT scan characteristics of PLCH are well recognized, the PET scan characteristics of adults with PLCH are unknown. METHODS: We identified 11 patients with ...
Bolus Norman E - - 2009
This article addresses the emerging technology of PET coupled with MRI, or PET/MRI, which could become the technology of choice in the future for many reasons. Some of these reasons will be discussed, along with a historical account of the field of MRI and how this modality has evolved to ...
Tatsumi Mitsuaki - - 2009
PURPOSE: To compare 2-deoxy-2-[F-18]fluoro-D-glucose-positron emission tomography (FDG-PET) and PET/computed tomography (CT) for certainty of image interpretation and for diagnostic accuracy in patients with primary and metastatic uterine cervical cancer. MATERIALS AND METHODS: Images of 13 patients with cervical cancer having PET/CT examinations were reviewed retrospectively. PET and PET/CT images of ...
Yerushalmi David - - 2009
PURPOSE: We present a systematic approach for studying positron emission tomography-computed tomography (PET/CT) 3-D virtual fly-through endoscopy and for assessing the accuracy of this technology for visualizing and detecting endobronchial lesions as a function of focal lesion morphology and activity. PROCEDURES: Capsules designed to simulate endobronchial lesions were filled with ...
Spier Bret J - - 2010
PURPOSE: The purpose of this study was to evaluate the appropriate 2-deoxy-2-[(18)F]fluoro-D-glucose-positron emission tomography (FDG-PET) determination in patients with inflammatory bowel disease (IBD) before and after clinical improvement to see if this determination correlates with clinical activity. PROCEDURES: We performed PET-computed tomography (PET/CT) on five patients before and after successful ...
Gerke Oke - - 2009
PURPOSE: For certain cancer indications, the current patient evaluation strategy is a perfect but locally restricted gold standard procedure. If positron emission tomography/computed tomography (PET/CT) can be shown to be reliable within the gold standard region and if it can be argued that PET/CT also performs well in adjacent areas, ...
Collantes M - - 2009
Normalization of neuroimaging studies to a stereotaxic space allows the utilization of standard volumes of interest (VOIs) and voxel-based analysis (SPM). Such spatial normalization of PET and MRI studies requires a high quality template image. The aim of this study was to create new MRI and PET templates of (18)F-DOPA ...
Truijers Maarten - - 2009
Preoperative positron emission tomography/computed tomography (PET/CT) was performed in 26 consecutive patients considered fit for aneurysm repair. Besides information on aneurysm wall pathology, PET/CT identified 6 patients with concomitant malignancy. As a result of this coincidental finding, the operation was postponed in 2 patients and cancelled in 1. Although previous ...
Nye Jonathon A - - 2009
PET/CT perfusion studies suffer from artifacts caused by misalignment of transmission and emission data due to contractile cardiac and respiratory motion. This study investigates whether substantial differences exist between two respiration-averaging approaches for attenuation correction (AC): low-pitch helical (HCT) and time-averaged CT (ACT). Fifty-four consecutive patients received paired HCT (0.45 ...
Berding Georg - - 2009
There is lack of consensus on radiotracer usage in hepatic encephalopathy (HE). We have focused our attention on three main areas: (i) radiotracer imaging in animal models of HE, (ii) methodological issues of radiotracer imaging in HE and (iii) radiotracer imaging studies on the pathophysiology and (new) therapies in HE. ...
Herrmann Ken - - 2009
Positron emission tomography (PET) and PET/computed tomography (CT) with the glucose analog (18)F-fluorodeoxyglucose (FDG) are increasingly used to assess response to therapy in patients, and there is converging evidence that changes in glucose utilization during therapy can be used to predict clinical outcome. Today, integrated PET/CT systems have mainly replaced ...
Cheng Ya-Min - - 2009
Positron emission tomography/computed tomography (PET/CT) is a functional imaging method of metabolic processes and is being used extensively in gynecologic oncology for treatment planning. However, some hypermetabolic conditions may mimic malignant neoplasms. We report a case with a positive finding at PET/CT examination of the uterus that proved to be ...
Rubin David T - - 2009
BACKGROUND: Positron emission tomography (PET) using 18-fluorodeoxyglucose (18-FDG) is a noninvasive, functional imaging modality most often used to assess cancer. The aim of this study was to perform PET/computed tomography (CT) on patients with quiescent ulcerative colitis (UC) to understand the limits of this technology for assessing inflammatory activity. METHODS: ...
Reichert Matthew - - 2009
Positron Emission Tomography (PET) with F-18-fluorodeoxyglucose is commonly used in the evaluation of lung nodules; however, there is limited data on the PET appearance of coal worker's pneumoconiosis (CWP) and its utility for diagnosing lung malignancy in this setting. Six cases of CWP and suspected malignancy are reported. Each patient ...
Shimamoto Hiroaki - - 2009
OBJECTIVE: The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. METHODS: A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch ...
Karam Irene - - 2009
PURPOSE: To study the possibility of incorporating positron emission tomography/computed tomography (PET/CT) information into radiotherapy treatment planning in patients with high-grade soft tissue sarcomas (STS). METHODS AND MATERIALS: We studied 17 patients treated with preoperative radiotherapy at our institution from 2005 to 2007. All patients had a high-grade STS and ...
Okazawa Hidehiko - - 2009
Positron emission tomography (PET) measurement of cerebral blood flow and metabolism has been a basic and standard method for evaluation of hemodynamics in patients with cerebral vascular disease (CVD). Despite the recent rapid spread of PET and PET/CT facilities, the number of patient examinations with (15)O-gas PET scans is declining ...
Herrmann Ken - - 2009
PURPOSE: The aim of this study was to assess the clinical value of [(11)C]methionine-PET (MET-PET) for detection and localization of parathyroid adenomas in patients without prior thyroidectomy. METHODS: A retrospective analysis of patients with suspected parathyroid adenomas undergoing imaging with MET-PET was performed. Prior thyroidectomy was an exclusion criterion. Forty-one ...
Ambrosini Valentina - - 2009
BACKGROUND: Conventional imaging techniques [computed tomography (CT), ultrasound, magnetic resonance] and somatostatin receptor scintigraphy are often insufficient to make a conclusive diagnosis of bronchial carcinoid (BC). PET is commonly used for the assessment of lung cancer but 18F-fluorodeoxyglucose, the most frequently used PET tracer, presents a low sensitivity for the ...
Martiniova L - - 2009
OBJECTIVE: The development of metastatic pheochromocytoma animal model provides a unique opportunity to study the physiology of these rare tumors and to evaluate experimental treatments. Here, we describe the use of small animal imaging techniques to detect, localize and characterize metastatic lesions in nude mice. METHODS: Small animal positron emission ...
Shortt Conor P - - 2009
OBJECTIVE: The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma. SUBJECTS AND METHODS: Twenty-four patients (13 women, 11 men; mean age, 67.1 years; range, ...