Search Results
Results 51 - 100 of 611
1 2 3 4 5 6 7 8 9 10 >
Ivanac G - - 2007
PURPOSE: Frequency encoded Doppler ultrasound (DUS) imaging has allowed identification of flow in thyroid tumours, but its role in evaluation of thyroid nodules for malignancy has not been accurately defined. We wanted to investigate the possible role of DUS in differentiation of benign and malignant nodules. MATERIALS AND METHODS: DUS ...
Sugeng Lissa - - 2007
Three-dimensional (3D) color Doppler echocardiography is a relatively new noninvasive tool that displays and quantitates regurgitant flow and also enables estimation of cardiac output, stroke volume, pulmonary outflow, and shunt calculations. This article provides an overview of the current methodology of 3D color flow, and its advantages and limitations.
Stone Michael B - - 2007
STUDY OBJECTIVE: Intraosseous access is widely used in pediatric and adult resuscitations when vascular access cannot be promptly established. Confirmation of intraosseous needle placement has traditionally relied on the ability to aspirate blood or marrow or infuse crystalloid easily. This study's aim is to determine the value of bedside ultrasonography ...
Raj Ganesh V - - 2007
PURPOSE: Traditional imaging techniques cannot differentiate among benign, indolent and malignant renal neoplasms. Since conventional clear cell carcinomas are highly vascular, we used preoperative color and/or power Doppler ultrasonography to evaluate the association between vascular flow in a renal mass and surgical pathology. MATERIALS AND METHODS: Nephrectomies performed at our ...
Artyukhin A A - - 2007
Three structural and hemodynamic variants of venous angioarchitectonics of the epididymis were detected: direct testicular outflow (direct outflow into veins of the plexus pampiniformis), indirect testicular outflow (outflow into veins of the plexus pampiniformis with involvement of the communicant veins), and mixed outflow (combination of indirect testicular outflow with the ...
Ginther O J - - 2007
Luteal blood flow was studied in heifers by transrectal color-Doppler ultrasound. Data were normalized to the decrease in plasma progesterone to <1 ng/ml (Day 0 or Hour 0). Blood flow in the corpus luteum (CL) was estimated by the percentage of CL area with color flow signals. Systemic prostaglandin F2alpha ...
Moreira Rubens M - - 2007
The influence of the inlet positions on the flow behavior inside a photoreactor has been studied using colored tracer and radiotracer investigations. The photoreactor for water disinfection is a tubular reactor inside which UV emitting lamps are placed. The key to its good performance is a combination of optimum irradiation ...
Nussbaum Blask Anna R - - 2006
OBJECTIVE: The purpose of this study was to determine the frequency of an enlarged epididymis in pediatric patients with testicular torsion and to determine whether an altered epididymis might be a helpful ancillary sonographic sign of testicular torsion. MATERIALS AND METHODS: The sonograms of 50 pediatric patients (age range, neonate-17 ...
Fujii Yoko - - 2006
OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ...
Hlavacek Anthony - - 2006
Two-dimensional transthoracic echocardiography (2DE) is the most commonly used diagnostic modality to evaluate congenital and acquired abnormalities of the aortic arch. However, 2DE is frequently limited in this ability due to the three-dimensional character of the arch and its interrelationships with other vascular structures. Recently, three-dimensional echocardiography (3DE) with 3D ...
Bogazzi Fausto - - 2006
BACKGROUND: Thyrotropin (TSH)-secreting pituitary adenoma (TSHoma) and resistance to thyroid hormone (RTH) are two forms of inappropriate TSH secretion. Thyroid blood flow is largely TSH dependent. OBJECTIVE: To assess whether thyroid blood flow may help to differentiate TSHoma and RTH. DESIGN: Intrathyroidal color flow Doppler sonography (CFDS) pattern and peak ...
Capraro Geoffrey A - - 2007
STUDY OBJECTIVE: To assess whether near-infrared spectroscopy can detect testicular hypoxia in a sheep model of testicular torsion within 6 hours of experimental torsion. METHODS: This was a randomized, controlled, nonblinded study. Trans-scrotal, near-infrared, spectroscopy-derived testicular tissue saturation of oxygen values were obtained from the posterior hemiscrota of 6 anesthetized ...
Diethrich Edward B - - 2006
The quality and interpretation of intravascular ultrasound (IVUS) imaging has been revolutionized in recent years by two new and major advances: virtual histology and color flow IVUS. Virtual histology intravascular ultrasound (VHIVUS) is a catheter-based technology where IVUS is generated from the transducer on the catheter tip and the reflected ...
Boesen Morten Ilum - - 2006
BACKGROUND: The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. HYPOTHESIS: The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, ...
Aigner Felix - - 2006
The arterial blood supply of the internal hemorrhoidal plexus is commonly believed to be associated with the pathogenesis of hemorrhoids. Ultrasound-supported proctoscopic techniques with Doppler-guided ligature of submucosal rectal arteries have been introduced for the therapy of hemorrhoids. The present investigation focuses on caliber and flow changes of the terminal ...
Asci R - - 2006
The ACE is found as two isozymes in the body. A somatic isozyme found in blood and several other tissues, and a testis-specific isozyme found only in developing spermatids and mature sperm. In this study, we investigated the ACE activity in left spermatic vein blood samples of infertile patients with ...
Tanriverdi Orhan - - 2006
OBJECTIVES: To compare the effects of the two most commonly used surgical methods in the management of varicocele disease, namely, microsurgery and high-ligation varicocelectomy, on testicular blood flow changes and mean residual index values in a prospective randomized study. METHODS: A total of 56 patients clinically diagnosed with varicocele were ...
Sophromadze Z - - 2006
It is recognized that due to muscle exercises cardio-vascular system undergoes various morphologic and functional changes among highly qualified sportsmen. Healthy vascular system is needed to meet successfully great physical load. Aim of the search was to study higher and lower extremity venous system functional condition during physical exercise and ...
Sato Takahiro - - 2006
BACKGROUND: The usefulness of endoscopic color Doppler ultrasonography (ECDUS) for evaluating hemodynamics is examined in 12 cases of rectal varices. We also evaluate the safety of endoscopic therapies in rectal variceal patients. METHODS: ECDUS was performed for 12 rectal variceal patients with a 7.5-MHz convex-type Pentax FG-32UA system. A Hitachi ...
Krapp M - - 2007
AIM: The purpose of the study was to investigate whether colour Doppler sonography is helpful in the surveillance of abnormal third stage of labour. MATERIALS AND METHODS: 20 patients were enrolled in the prospective study. Inclusion criteria were third stage of labour > 15 min and/or clinical suspicion of retained ...
Zaidi Qasim - - 2006
The role of chromatic information in 3-D shape perception is controversial. We resolve this controversy by showing that chromatic orientation flows are sufficient for accurate perception of 3-D shape. Chromatic flows required less cone contrast to convey shape than did achromatic flows, thus ruling out luminance artifacts as a problem. ...
Kristoffersen H - - 2006
PURPOSE: Ultrasound examination of a group of patients with osteoarthritis (OA) of the knee for signs of inflammation. MATERIAL AND METHODS: 71 knees in 71 patients with osteoarthritis of the knee were examined with high-resolution gray-scale ultrasound combined with color and spectral Doppler. The medial, lateral, and antero-superior compartments were ...
Doepp Florian - - 2006
Herpes simplex virus encephalitis (HSVE) typically affects the baso-temporal brain. The venous blood drainage of this region mainly occurs via the basal vein of Rosenthal (BVR), which can easily be monitored by transcranial color-coded duplex sonography (TCCS), and might be a useful parameter for the activity of the disease. Serial ...
Lissbrant E - - 2006
Developing germ cells may be sensitive to even moderate reductions in blood flow. Surprisingly, however, experimental evidence suggests that the rat testis may be unable to maintain its blood flow during a decrease in systemic blood pressure. This study was therefore performed in order to answer the following questions: Is ...
Alcázar Juan Luis - - 2006
OBJECTIVE: The purpose of this study was to assess the intraobserver and interobserver agreement for identifying different endometrial vascular patterns using power Doppler sonography in women with postmenopausal bleeding and a thickened endometrium. METHODS: Digitally stored sonographic images from a random sample of 65 patients with postmenopausal bleeding and a ...
Liang Ching-Chung - - 2006
BACKGROUND: This study was designed to test the hypothesis that decreased periurethral vascularization and blood flow might lead to urinary incontinence. Three-dimensional color histogram may better quantify the vasculature than traditional two-dimensional Doppler ultrasound imaging. METHODS: Between June 2002 and July 2003, 57 patients were invited to undergo three-dimensional power ...
de la Pena Erasmo - - 2006
CMR is valuable in the evaluation of congenital heart disease (CHD). Traditional flow imaging sequences involve cardiac and respiratory gating, increasing scan time and susceptibility to arrhythmias. We studied a real-time color-flow CMR system for the detection of flow abnormalities in 13 adults with CHD. All 16 congenital flow abnormalities ...
Yücel Cem - - 2005
OBJECTIVE: The purpose of this study was to determine the effectiveness of B-flow sonography in the evaluation of hemodialysis fistulas and to compare this new technique with color and power Doppler sonography. METHODS: In this study, 32 randomly selected patients (mean age, 46 years; age range, 18-87 years) with normally ...
Kurita Seiichiro - - 2005
We have utilized color Doppler ultrasonography (CDU) to evaluate the thyroid blood flow area (TBFA) quantitatively, and we propose criteria to differentiate Graves' disease (GD) and destruction-induced thyrotoxicosis (DT) in patients with thyrotoxicosis. We studied 32 patients with diffuse toxic goiter, 21 with GD in the euthyroid state, 12 with ...
Bartels Eva - - 2005
OBJECTIVE: The clinical value of transcranial color-coded duplex sonography (TCCS) in the evaluation of arteriovenous malformations (AVMs) has not yet been fully investigated. In this study, 54 intracranial AVMs confirmed by angiography were prospectively examined over 6 years. The purpose of the study was to describe their typical sonographic features ...
Kwon Jong Won - - 2005
RATIONALE AND OBJECTIVE: We sought to determine whether torsed testis viability can be evaluated by ultrasonography (US) including power Doppler US in an experimental model of acute testicular torsion. METHOD: Eighteen rats underwent unilateral 540 degrees testicular torsion and contralateral orchiopexy. Gray-scale and power Doppler US were performed 24 hours ...
Lee Nam-Ho - - 2005
PURPOSE: We investigated hemodynamic changes in the ophthalmic artery (OA) using color Doppler imaging (CDI) after two horizontal rectus muscles surgery. METHODS: Eyes of the surgical group (n=18) underwent surgery on two horizontal rectus muscles, and the control group was the contralateral eyes. CDI of the OA was performed before ...
Yamaguchi Akiko - - 2005
A 13-year-old-boy with suspected left testicular torsion was referred to our institute. During preparation, a significant decrease of signals on the left testis was found, however, slight blood flow was detected by the ultrasound examination enhanced by Levovist. As a result of the examination we left the testis intact, although ...
Zülke Carl - - 2005
OBJECTIVE: To compare portal vein flow values gained by color flow Doppler sonography with simultaneously derived data from an ultrasound transit time flow probe. DESIGN: Repeated, simultaneous flow measurements were performed in a prospective study investigating the effect of various drugs on hepatosplanchnic perfusion and energy balance in a long-term ...
De Nicola Harley - - 2005
OBJECTIVES: The purpose of this study was to evaluate whether flow pattern and resistive index (RI) are useful parameters for distinguishing benign from malignant thyroid follicular neoplasms (FNs). METHODS: Eighty-six thyroid nodules that underwent sonographically guided fine-needle aspiration and were diagnosed as cases of FN were evaluated by power and ...
Nishiyama Yasuhiro - - 2005
Varicocele rupture was diagnosed in a 23-year-old man who presented with swelling and pain in the left scrotum after sexual intercourse. Color Doppler ultrasonography revealed blood flowing into the space surrounding the left testis, a hematoma and reflux of blood in the left spermatic vein. Varicocele rupture is a very ...
Li Xiaokui - - 2005
AIMS: Laminar flow stroke volume (SV) quantification in the ascending aorta or pulmonary artery can provide a measure for determining cardiac output (CO). Comparing flows across different valves can also compute shunt volumes and regurgitant fractions. Quantification methods for 3D color Doppler laminar flow volumes have been developed using reconstructive ...
Morel M - - 2005
The purpose of this study was first to determine the normal blood supply of the heel entheses with cadaver injection, and second, to identify by means of ultrasound (US) this blood supply in healthy volunteers before and after the intravenous injection of a US contrast agent (SonoVue). Twenty cadaver lower ...
Faingold Ricardo - - 2005
PURPOSE: To determine whether absence of bowel wall perfusion at color Doppler ultrasonography (US) is indicative of bowel necrosis in neonates with necrotizing enterocolitis (NEC). MATERIALS AND METHODS: This study was approved by the research ethics board, and informed consent was obtained. Sixty-two neonates enrolled in the prospective study underwent ...
Ho S S Y - - 2005
OBJECTIVE: Compromised cerebral vasoreactivity increases the risk of stroke. In this study, we sought to determine whether extracranial arterial blood flow volume measured on color velocity imaging quantification could be predictive of cerebral vasoreactivity after the administration of acetazolamide. SUBJECTS AND METHODS: Cerebral blood flow and extracranial arterial blood flow ...
Nagai Atsushi - - 2005
OBJECTIVES: To observe the phenomenon of human ejaculation dynamically using color Doppler ultrasonography. METHODS: Human ejaculation was observed using transrectal color Doppler ultrasonography in a healthy man and a patient with retrograde ejaculation. Ejaculation was induced manually with audiovisual sexual stimulation. The ejaculatory phenomenon was analyzed and compared with that ...
Mess W H - - 2005
BACKGROUND: Analysis of microembolic signals (MES) suggests a change of flow direction (CFD). The aim of the present study was to relate MES direction in an amplitude plot, based on the radiofrequent (RF) signal, to the vascular anatomy as seen with transcranial color-coded duplex (TCCD). METHODS: In 5 patients undergoing ...
Sato Ai - - 2005
Synovial vascularization was analyzed by power Doppler and spectral Doppler sonography in 42 knee joints of 28 patients with rheumatoid arthritis. The synovial vessels with greater intensity of color flow signals demonstrated significantly lower indicators of vascular resistance - resistive index (P < 0.01) and pulsatility index (P < 0.01) ...
Nakagawa Koji - - 2005
PURPOSE: Color Doppler imaging permits the accurate localization of vessels and high-frequency pulsed Doppler ultrasonography has improved the resolution of flow velocity waveforms. In this study, intraovarian arterial blood flow before and after follicle rupture in the natural cycle was examined using transvaginal color flow Doppler imaging and changes in ...
Yang Dal Mo - - 2005
OBJECTIVE: The purpose of this study was to compare the size, shape, echogenicity, and blood flow of the appendix testis on sonography in control subjects and in patients with a torsed appendix testis and to evaluate the usefulness as well as the limitations of these criteria. METHODS: This was a ...
Krzymowski T - - 2005
Radiolabeled testosterone (3H-T) was infused into the testes or left and right mesofuniculus (106 dpm) or injected into a testes (2 x 10(6) dpm). The 3H-T concentration was estimated 15 or 10 min after 3H-T infusion or injection, respectively, in the tissue samples collected from the prostate, seminal vesicles, caput ...
Kasukawa Reiji - - 2005
Synovial vascularity of 12 patients with rheumatoid arthritis (RA) was examined by Doppler sonography for color flow signals and vascular resistance on knee joints and metacarpophalangeal (MCP) joints, and the results were compared with each other and with C-reactive protein (CRP) levels of the patients. A significant correlation was observed ...
Sato Takahiro - - 2005
BACKGROUND: We examined the usefulness of endoscopic color Doppler ultrasonography, using Levovist in evaluating the arterial blood flow, in patients with esophageal varices. METHODS: The study involved 110 patients with esophageal varices who were examined using endoscopic color Doppler ultrasonography (ECDUS). We compared vessel images detected by pre-contrast ECDUS with ...
Souza C A B - - 2005
PURPOSE: To evaluate power Doppler ultrasonography to predict sperm recovery in azoospermic patients. METHODS: Color Doppler and power Doppler ultrasonography of testis were performed in 38 patients before testicular sperm extraction. Analysis of blood flow included the pulsatility and resistance index of intratesticular vessels and testicular artery, and power Doppler ...
Ardicoglu Arslan - - 2005
PURPOSE: To evaluate erectile dysfunction, penile color Doppler ultrasound is currently considered the best method. But intracavernous injection is invasive and has adverse effects, such as prolonged erection and risk of priapism. In our study we want to evaluate whether vardenafil can be used instead of papaverine in penile Doppler ...
1 2 3 4 5 6 7 8 9 10 >