| Results 1 - 50 of 752 | ||
| 1 2 3 4 5 6 7 8 9 10 > | ||
|
Perry D W J - - 2012
The ability to electrically stimulate neural and other excitable tissues in behaving experimental animals is invaluable for both the development of neural prostheses and basic neurological research. We developed a fully implantable neural stimulator that is able to deliver two channels of intra-cochlear electrical stimulation in the rat. It is ...
|
||
|
Garrett David J - - 2011
Diamond is well known to possess many favourable qualities for implantation into living tissue including biocompatibility, biostability, and for some applications hardness. However, conducting diamond has not, to date, been exploited in neural stimulation electrodes due to very low electrochemical double layer capacitance values that have been previously reported. Here ...
|
||
|
Ereifej Evon S - - 2011
Neural electrode devices hold great promise to help people with the restoration of lost functions. However, research is lacking in the biomaterial design of a stable, long-term device. Glial scarring is initiated when a device is inserted into brain tissue and an inflammatory response ensues. Astrocytes become hypertrophic, hyperplastic, and ...
|
||
|
Carvalho Ana Claudia Martinho de - - 2011
The electrical stimulation generated by the Cochlear Implant (CI) may improve the neural synchrony and hence contribute to the development of auditory skills in patients with Auditory Neuropathy/Auditory Dyssynchrony (AN/AD). Prospective cohort cross-sectional study to evaluate the auditory performance and the characteristics of the electrically evoked compound action potential (ECAP) ...
|
||
|
A 32-channel fully implantable wireless neurosensor for simultaneous recording from two cortical ...
Aceros Juan - - 2011
We present a fully implantable, wireless, neurosensor for multiple-location neural interface applications. The device integrates two independent 16-channel intracortical microelectrode arrays and can simultaneously acquire 32 channels of broadband neural data from two separate cortical areas. The system-on-chip implantable sensor is built on a flexible Kapton polymer substrate and incorporates ...
|
||
|
Wilks Seth J - - 2011
Maintaining a reliable neural interface is a well-known challenge with implanted neural prostheses. Here we evaluate a method of forming an integrated neural interface through polymerization of PEDOT in vivo. Polymerization resulted in lower impedance and improved recording quality of local field potentials on implanted electrodes in the rat cerebral ...
|
||
|
Gosselin Benoit - - 2011
The accelerating pace of research in neurosciences and rehabilitation engineering has created a considerable demand for implantable microsystems capable of interfacing with large groups of neurons. Such microsystems must provide multiple recording channels incorporating low-noise amplifiers, filters, data converters, neural signal processing circuitry, power management units and low-power transmitters to ...
|
||
|
Al-Armaghany Allann - - 2011
The emerging neural-silicon interface devices bridge nerve systems with artificial systems and play a key role in neuro-prostheses and neuro-rehabilitation applications. Integrating neural signal collection, processing and transmission on a single device will make clinical applications more practical and feasible. This paper focuses on the wireless antenna part and real-time ...
|
||
|
Borton David - - 2011
A new model has been established in the domestic pig for neural prosthetic device development and testing. To this end, we report on a complete neural prosthetic developmental system using a wireless sensor as the implant, a pig as the animal model, and a novel data acquisition paradigm for actuator ...
|
||
|
Zhang Fei - - 2011
Conditioning raw neural signals recorded through microelectrode arrays implanted in the brain is an important first step before information extraction can take place. This paper reports on the design and implementation of a programmable and fully implantable microsystem that fulfills this purpose. The system design builds on our earlier work ...
|
||
|
Rush Alexander - - 2011
This paper reports a dual inductive link to provide two-way wireless communication and power for a neural recording system. Particular emphasis is placed on explaining the challenges associated with two inductive links operating in the same space and possible solutions. This system uses a class E converter to sustain a ...
|
||
|
Weiland James D - - 2011
Implantable neural interfaces provide substantial benefits to individuals with neurological disorders. That was the unequivocal message delivered by speaker after speaker from the podium of the 39th Neural Interfaces Conference (NIC2010) held in Long Beach, California, in June 2010. Giving benefit to patients is the most important measure for any ...
|
||
|
Flexer Carol - - 2011
Hearing loss is primarily a brain issues, not an ear issue. Technology, e.g. cochlear implants and hearing aids are necessary to reach the brain of a child with hearing loss in order to create a neural structure for listening, language and literacy. The brain requires a great deal of auditory ...
|
||
|
Zhu Meimei - - 2011
OBJECTIVES: Because of difficulties associated with pediatric speech testing, most pediatric cochlear implant (CI) speech studies necessarily involve basic and simple perceptual tasks. There are relatively few studies regarding Mandarin-speaking pediatric CI users' perception of more difficult speech materials (e.g., words and sentences produced by multiple talkers). Difficult speech materials ...
|
||
|
Vasavada Abhay R - - 2011
We describe a technique of pars plicata manual posterior capsulorhexis performed after implantation of an intraocular lens (IOL) in pediatric cataract surgery. The technique can be used to create a posterior capsulectomy of a desirable size in a controlled manner to avoid destabilization of the IOL. It can be applied ...
|
||
|
Green K M J - - 2011
This study aimed to examine auditory and visual cortical activations in bilateral cochlear implant recipients using [(18)F]-FDG positron emission tomography. We aimed to compare the activations from use of the first implant alone, the second implant alone, and both implants together. When both implants were activated simultaneously, summation of cortical ...
|
||
|
Sparta Dennis R - - 2011
In vivo optogenetic strategies have redefined our ability to assay how neural circuits govern behavior. Although acutely implanted optical fibers have previously been used in such studies, long-term control over neuronal activity has been largely unachievable. Here we describe a method to construct implantable optical fibers to readily manipulate neural ...
|
||
|
Chuang Shu-Fen - - 2010
Cast posts require sufficient length for prosthesis retention and root strength. For prefabricated metal and fiber posts, the effects of different post lengths on the strength and internal stress of the surrounding root need evaluation. The purpose of this study was to examine, using both experimental and finite element (FE) ...
|
||
|
Silva N R F A - - 2011
This study tested the hypothesis that all-ceramic core-veneer system crown reliability is improved by modification of the core design. We modeled a tooth preparation by reducing the height of proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. The CAD-based tooth preparation was replicated and positioned in ...
|
||
|
Uy Joanne N - - 2010
In badly damaged teeth and teeth with short clinical crown heights, the placement of foundation restorations has been advocated to permit the development of retention and resistance form. However, there is little information on the effect of these foundation restorations on the clinical performance of the definitive restoration. The purpose ...
|
||
|
Rasimick Brian J - - 2010
Previous clinical studies indicated loss of retention between dowel and tooth was a major cause of failure for passive endodontic dowels. Advances in luting cement technology may have improved the retention of dowels. The purpose of this systematic review was to determine the clinical failure modes for dowel/core/crown restorations luted ...
|
||
|
Floerkemeier Thilo - - 2011
The osteonecrosis of the femoral head implies significant disability partly due to pain. After conventional core decompression using a 10-mm drill, patients normally are requested to be non-weight bearing for several weeks due to the risk of fracture. After core decompression using multiple small drillings, patients were allowed 50% weight ...
|
||
|
Hatta Minori - - 2011
The purpose of this study was to evaluate the fracture loads of post-and-core systems with two different individually formed fibre post designs and polymerization conditions. Totally seventy-two (n=8/group) bovine teeth were cut and made up the root length of 15.0mm. They were divided into 3 main groups (Group A, B, ...
|
||
|
Naumann M - - 2011
To investigate the load capability of root filled teeth restored with glass fibre posts when the same self-adhesive composite resin cement was used as post cement and core build-up material. Human maxillary central incisors were divided into four groups (n=10). Teeth were root filled, decoronated and restored using glass fibre ...
|
||
|
Erdemir Ugur - - 2010
The objective of this study was to evaluate the push-out bond strengths of carbon and glass fiber posts adhesively luted with Panavia F 2.0 and RelyX Unicem luting cements, as well as a modified application procedure using RelyX Unicem cement in combination with a single-bottle total-etch adhesive in 3 segments ...
|
||
|
Hikasa Takayuki - - 2010
The aim of this study was to compare the core survival rates (CSRs) of cast metal versus resin core restorations luted with adhesive resin cement, as well as to determine the risk factors for core failure. Nine hundred ninety-one patients (2,124 cores) who received either cast metal or resin cores ...
|
||
|
Pereira Priscilla Cristoforides - - 2010
The aim of this study was to evaluate the influence of two adhesive systems and the post space region on the degree of conversion of dual resin cement and its bond strength to root dentin. One three-step etch-and-rinse (All-bond 2, Bisco) and another one-step self-etch (Xeno III, Dentsply) adhesive systems ...
|
||
|
Brito-Junior Manoel - - 2010
The aim of this study was to evaluate the effect of simulated periodontal ligament (SPDL) on custom cast dowel and core removal by ultrasonic vibration. Thirty-two human maxillary canines were included in resin cylinders with or without SPDL made from polyether impression material. In order to allow tensile testing, the ...
|
||
|
Garbin C A - - 2010
To compare stress distribution between a fractured maxillary central incisor restored with direct composite resin only (CR) or associated with different post materials, using finite element analysis. A three-dimensional model of a sound maxillary central incisor and supporting structures was constructed, using data from the dental literature. Changes were made ...
|
||
|
Gómez-Polo Miguel - - 2010
The aim of this retrospective study was to compare the cumulative survival rate of teeth restored with prefabricated posts and with cobalt-chrome cast post-cores. 112 endodontically treated teeth restored with prefabricated post and cobalt-chrome cast post-and-cores were evaluated. Teeth were considered as failures when were objective or radiologic sign of ...
|
||
|
Mao Haiyan - - 2011
The purpose was to investigate by push-out tests and scanning electron microscopy (SEM)/energy-dispersive spectroscopy (EDS) the effect, after first acid etching the post space walls, of three radicular dentine treatments on the regional bond strength of quartz fibre posts placed using two heavily filled resin luting cements. The crowns of ...
|
||
|
Coniglio Ivanovic - - 2011
This study aimed at evaluating the post-root dentin push-out bond strength of circular and oval posts luted in oval-shaped canals with two different resin cements. Twenty extracted premolars with oval-shaped canals were selected, endodontically instrumented and obturated. The teeth were divided into two groups according to the drill used for ...
|
||
|
Macedo Vanessa Cruz - - 2010
As opposed to the cementation metal posts, the cementation of fiber posts has several details that can significantly influence the success of post retention. This study evaluated the effect of the relining procedure, the cement type, and the luted length of the post on fiber posts retention. One hundred eighty ...
|
||
|
Zorba Yahya Orçun - - 2010
The aim of this study was to evaluate the effects of different curing units and 2 luting cements on the push-out bond strength of a translucent fiber post. Thirty maxillary incisor roots were endodontically treated. Post spaces were prepared, and the smear layers were removed. Posts (FRC Postec Plus) were ...
|
||
|
Baldissara P - - 2010
This study evaluated the performance of different adhesive-cement-core combinations coupled with quartz fiber dowels after cyclic loading and fracture strength tests and assessed the microleakage using dye penetration method. Forty maxillary canines (N=10 per group) were restored with fiber dowels (Quartz fiber DT Light Post) and four adhesive-cement-core material combinations ...
|
||
|
Lindblad Ritva M - - 2010
Chlorhexidine is used as final irrigant before endodontic obturation and fiber-reinforced composite posts are recommended for restoration retention. Our aim was to evaluate the effect of chlorhexidine on adhesion of cements used in post cementation. We hypothesized that chlorhexidine would not negatively affect the immediate bond strength. Root canals of ...
|
||
|
Liu Peng - - 2010
Prefabricated glass fiber posts are widely used; however, their shape cannot be changed and they can be unsuitable for severely damaged teeth with wide root canals. This clinical report describes a procedure for restoring a severely damaged anterior tooth with a customized 1-piece glass fiber post and core, fabricated using ...
|
||
|
- - 2010
In this in vitro study, 'grayish gingival shadowing cannot be reduced with white posts'.
|
||
|
Rödig Tina - - 2010
PURPOSE: To evaluate the bond strength between two fiber posts (FRC Postec and DT Light Post) and different composite resins following different surface treatments of the posts. MATERIALS AND METHODS: One hundred sixty extracted teeth were divided into sixteen groups (n = 10). After pretreatment of the post surface with ...
|
||
|
Bittner Nurit - - 2010
One-piece milled zirconia posts and cores present an esthetic option as foundation restorations for ceramic crowns. To date, dimensional fit and load capacity of 1-piece zirconia posts and cores have not been determined. The purpose of this study was to evaluate the accuracy of fit of milled zirconia posts and ...
|
||
|
Naumann M - - 2010
The aim of this investigation was to test the in vitro performance of a self-adhesive resin composite core build-up in comparison with two typical conventional etch-and-rinse composite core build-up materials, before and after 1year of storage in 0.5% chloramine solution (LTS). Sixty human maxillary central incisors were divided into three ...
|
||
|
Papadopoulos Triantafillos - - 2010
The aim of this study was to evaluate the mechanical behavior of endodontically treated teeth restored with fiber reinforced composite posts versus titanium posts, by both experimental testing and numerical simulation (finite element analysis (FEA)). Forty maxillary central incisors were endodontically treated to a size 45 file and then obturated ...
|
||
|
Mumcu Emre - - 2010
By means of a micro push-out test, this study compared the bond strengths of two types of fiber-reinforced posts cemented with luting cements based on two currently available adhesive approaches as well as evaluated their failure modes. Sixty extracted single-rooted human maxillary central incisor and canine teeth were sectioned below ...
|
||
|
Kivanç Bagdagül Helvacioglu - - 2010
The aim of the study was to compare the fracture resistance of maxillary premolars with one remaining cavity wall restored using different post systems. Forty-eight maxillary premolars were endodontically treated and randomly assigned to four groups for postcore restoration. The first three test groups were restored with polyethylene woven fiber ...
|
||
|
Lencioni Karina Albino - - 2010
The purpose of this study was to compare the tensile strength of commercially pure titanium dowels and cores cemented with zinc phosphate or resin cements. Twenty-one extracted human canines were endodontically treated. The root preparations were accomplished using Largo reamers (10mm in depth and 1.7 mm in diameter). Acrylic resin ...
|
||
|
Prithviraj D R - - 2010
BACKGROUND AND OBJECTIVES: There are numerous post and core systems variety of materials. Several methods are used to increase the retentive strength.The present study was conducted with the purpose of analysis of the effect of surface treatment with ethyl alcohol, resin primer and air-borne alumina particle abrasion on retention of ...
|
||
|
Davis Peter - - 2010
The aims of this study were to evaluate the flexural strength of two different types of glass fibre-reinforced posts bonded to dual-cure composite resin cements. Forty glass methacrylate-based fibre posts (GC Fiber Post) and 20 glass fibre inter-polymerizing network posts (everStick POST) were divided into three groups. Group 1 contained ...
|
||
|
Bönecker-Valverde Guilherme - - 2010
The purpose of the present study was to evaluate the in vitro seal capability of interim post and core crown restorations. Eighty teeth were selected and divided into 8 groups. Four experimental groups received interim posts and core crowns. Half of each group was decoronated at the cementum-enamel junction, groups ...
|
||
|
Schmitter M - - 2010
In dentistry the restoration of decayed teeth is challenging and makes great demands on both the dentist and the materials. Hence, fiber-reinforced posts have been introduced. The effects of different variables on the ultimate load on teeth restored using fiber-reinforced posts is controversial, maybe because the results are mostly based ...
|
||
|
Hattori Masayuki - - 2010
The aim of this study was to evaluate the durability of unidirectional and bidirectional fiber-reinforced post systems under static and cyclic loading. Three prefabricated fiber posts with one of two core composite resins each or a post resin were used. Each specimen was subjected to a three-point bending test after ...
|
||
| 1 2 3 4 5 6 7 8 9 10 > | ||