Peeters A J - - 1991
In recent studies from Sweden an increased prevalence of HLA-B27 associated diseases and of HLA-B27 was found in an unselected group of men with permanently implanted pacemakers and with a heart block. Furthermore, a significantly increased prevalence of HLA-B27 was found in men with a pacemaker who had no clinical ...
Van Erckelens F - - 1991
The case of a woman with an asymptomatic transvenous left ventricular endocardial pacemaker lead is presented. The chest X ray and the electrocardiogram suggested pacemaker catheter malposition. By two-dimensional echocardiography, the pacemaker lead was shown to cross from the left atrium through the mitral valve and implant in the left ...
van Gelder L M - - 1991
Holter recording of a patient with an implanted dual chamber rate responsive pacemaker revealed an electrocardiogram, where ventricular depolarization seemed to be initiated by the atrial stimulus. In a second patient with a VVI pacemaker, Holter recording showed delay of the pacemaker impulse that was registered after the onset of ...
Silka M J - - 1991
A young patient, who experienced a cerebral embolic event 30 days after transvenous pacemaker lead placement, is reported. This patient had previously been paced with an epicardial lead without evidence of right to left intracardiac shunt. However, hemodynamic evaluation post-embolism demonstrated a marked temporal disparity of the pulmonary and systemic ...
Myers M R - - 1991
Within a few months of implantation, permanent pacemaker leads become ensheathed in fibrocollagenous tissue. This tissue may anchor the lead so that it is difficult, dangerous, or impossible to remove it. Leads with bulbous or finned tips are particularly resistant to extraction. The risks of applying traction to an entrapped ...
Walsh E G - - 1991
The resonant frequency of the wrist has been measured in sixteen hypermobile and nine normal women at ten levels of peak torque. At the lowest level the results were identical but at the others the hypermobile values were lower. Damping and thixotropy appeared to be normal. In another group the ...
Korzets A - - 1991
Two cases of subclavian vein stenosis secondary to permanent cardiac pacemakers are presented. Both stenoses were asymptomatic until arteriovenous fistulae/grafts were constructed in order to initiate haemodialysis. One patient experienced severe oedema of the arm which necessitated surgical closure of the graft. A literature review into major venous stenosis and ...
Benrey J - - 1991
During their 33-year history of clinical use, cardiac pacemakers have evolved from devices primarily intended to save lives into complex systems designed to improve the cardiac patient's overall quality of life. To help physicians cope with this rapidly changing field, this review outlines current indications for pacemaker therapy and examines ...
Della Bella P - - 1990
Holter monitoring in a 75-year-old man with a VVI pacemaker with rate hysteresis and concomitant quinidine treatment documented the occurrence of several episodes of non-sustained polymorphous ventricular tachycardia, triggered by each first paced beat following the longer escape interval. These arrhythmias disappeared when quinidine was withdrawn or when the pacemaker ...
Kirby R L - - 1990
Coupling between cardiac and locomotor rhythms has been identified while people walk, run, hop and cycle at cadences natural to them. To test the hypothesis that cardiac-locomotor coupling occurs during finger tapping, we studied 20 normal subjects tapping a telegraph key at a comfortable rate for 10 min. 15 subjects ...
Vanerio G - - 1990
STUDY OBJECTIVE: Determine the effect of percutaneous catheter ablation (CA) on permanent pacemakers. MEASUREMENTS AND RESULTS: Twenty-three patients who underwent CA at The Cleveland Clinic Foundation from September 1983 to January 1990, and had a previously implanted pacemaker were studied. Electrocardiographic data during the CA procedure and clinic data including ...
Cosentino S - - 1990
The occurrence of pollens and molds in the atmosphere of Cagliari, Italy over a 3-year period (1986-88) is reported. Pollen grains are present in the air from February to July, with a maximum in May. Urticaceae and Cupressaceae were the major contributors to the total pollen airspora, followed by Graminaceae, ...
Grier D - - 1990
The chest radiographs of 600 consecutive patients undergoing insertion of a permanent cardiac pacemaker were reviewed to determine the incidence and nature of abnormalities present. Abnormalities were detected on the chest radiographs of 131 patients (21.8%). Unsatisfactory electrode tip position and other features related to the electrode wire were commonest ...
DeHaan K C - - 1990
Forty-three pregnant Dorset and Dorset crossbred ewes were assigned randomly to a control group or implanted with either 300 mg trenbolone acetate (Low TBA) or 1,200 mg trenbolone acetate (High TBA) between d 40 and 60 of gestation. Adjusted weaning weights for ewe lambs were 23.3% less (P less than ...
Durand L G - - 1990
A surgical protocol was designed to implant in dogs a programmable atrioventricular pacemaker and to destroy the bundle of His with one to four 0.1 ml formaldehyde injections. The heart rate and P-R interval were paced at 100 beats min-1 and 75 ms, respectively. Cardiac inotropy was then varied in ...
Kertes P J - - 1990
In Australia, most patients requiring permanent cardiac pacing have either high grade atrioventricular block or sick sinus syndrome. Many receive simple ventricular demand pacemakers, but more 'physiological' systems are now available that allow changes in pacing rate depending on metabolic needs. The indications for pacemakers and the types available are ...
Marshall I - - 1990
Some patients undergoing cardiothoracic surgery require cardiac pacing. Surgical diathermy interferes with the operation of external pacemakers, and can cause a loss of cardiac output. The addition of a simple two-stage LC filter to the front end of the pacemaker enables cardiac output to be maintained during the use of ...
Sturgis L M - - 1990
4 physiological measures--electromyogram, respiration rate, heart rate, and skin conductance--were recorded for 11 high and 11 low hypnotizable Ss. It was hypothesized (a) that physiological responsiveness during hypnosis would vary depending on the nature of the task instructions, and (b) that high hypnotizable Ss would show more physiological responsiveness than ...
Masterson M M - - 1990
In order to analyze the impact of different polarity and electrode designs on the acute pacing and sensing characteristics of pacemaker leads, 80 patients with complete heart block or sinus node dysfunction undergoing pacemaker implantation received eight different leads from five manufacturers. Once the leads were positioned, volt and current ...
Masterson M - - 1990
The judicious use of antitachycardia pacemakers can enhance the benefits of automatic implantable cardioverter defibrillators in certain patients. Both devices were implanted in 10 highly selected patients with drug-refractory pace-terminable sustained ventricular tachycardia. During the observation period of 8 +/- 4.8 months, the automatic pacemakers detected 1,542 episodes of ventricular ...
Pelleg A - - 1990
Adenosine exerts pronounced depressant effects on cardiac pacemakers. Previous studies in vitro have indicated that different pacemakers exhibit variable sensitivity to adenosine: ventricular greater than junctional greater than sinus node pacemakers. This study tested the hypothesis that ventricular pacemakers are more sensitive to adenosine than sinus node pacemakers in vivo ...
Chew P H - - 1990
An 81-year-old man was treated for high degree AV block and syncope with an AV universal (DDD) pacemaker. Bipolar active fixation atrial and ventricular leads were used. Intermittent oversensing from the ventricular lead was detected on Holter monitoring following implantation. This resulted in inappropriate inhibition of ventricular pacing. Ventricular electrogram ...
So L Y - - 1990
A baby with congenital heart block and hydrops fetalis diagnosed prenatally was delivered at 36 weeks of gestation. Heart failure was controlled with temporary cardiac pacing which was complicated by perforation of the myocardium. She made an uneventful recovery after implantation of a permanent pacemaker. Sjögren's syndrome A antibodies were ...
Vera Z - - 1990
Elective cardioversion was undertaken in a patient with a VVI pacemaker and atrial tachyarrhythmia after converting the pacemaker to a VOO mode of function. The cardioverter output energy was unwittingly synchronized to the pacemaker output pulses that were falling randomly in various portions of the cardiac cycle. This resulted in ...
Das G - - 1990
Artificial pacemakers are electronic devices used primarily to control cardiac rate in patients in whom the intrinsic heart rate is inadequate for a normal life style. These devices automatically and rhythmically provide electrical impulses to stimulate the heart. Electrical stimulation of various organs of the human body was already in ...
Mori Y - - 1990
Practical method was devised for precise approach to hypothalamic nuclei in the Shiba goat. A stereotaxic instrument and a brain atlas with stereotaxic coordinates were developed. For an accurate placement of probes into specific hypothalamic regions a radiographic method was employed in which radio-opaque material was injected into the lateral ...
Evans L - - 1990
The effectiveness of air cushion restraint systems, or airbags, in preventing fatalities is estimated by assuming that they do not affect ejection probability, and protect only in frontal, or near frontal, crashes with impact-reducing effectiveness equal to that of lap/shoulder belts. In order to compute airbag effectiveness, lap/shoulder belt effectiveness ...
Garson A A - - 1990
A method is presented for obtaining data about a pacemaker from a routine ECG without any prior information about the type of pacemaker or the pacemaker parameters. The method begins with assessment of the mode of the pacemaker (AAI, VVI, VDD, DVI, or DDD) and the presence of physiologic sensing. ...
Theiss M - - 1990
Between May 1985 and July 1988, 11 patients with cardiac pacemakers were treated for renal or ureteral calculi by extracorporeal shock wave lithotripsy. During treatment and at follow-up no dysfunction of the pacemakers was noted. There were no cardiac complications during extracorporeal shock wave lithotripsy. All 11 patients were free ...
Tan U - - 1990
Paw preference assessed by a food-reaching test was studied in male and female cats. Of the total sample (N = 66), 34 (51.5%) were right-preferent, 24 (36.4%) left-preferent, and 8 (12.1%) ambilateral. In the total sample, there was evidence for an overall paw preference, general paw preference, right-, and left-paw ...
Björnström M - - 1990
Five saliva stimulants (Salivin, V6, Mucidan, Ascoxal-T and Nicotinamide) and three saliva substitutes (Saliment, Salisynt and an ex témpore solution) were evaluated in 106 patients with a low salivay flow rate and a long history of dry mouth. The study was carried out as a multi-centre study in collaboration with ...
Silver P J - - 1990
Cyclic nucleotide phosphodiesterase (PDE) isozymes isolated by DEAE-Sephacel or Mono-Q High Performance Liquid Chromatography from cardiac left ventricular tissue of normal subjects and patients with end-stage heart failure have been compared. With both separation techniques, four major peaks of PDE activity were evident in the soluble fractions; only one peak ...
Callaghan F J - - 1990
An overview of advances is presented. The focus is on automatic functions that have been developed to monitor the patient continuously and readjust the postventricular atrial refractory period, the atrioventricular (AV) delay, the ventricular refractory period, and the pacemaker stimulus intensity. The advent of automatic algorithms for the postventricular atrial ...
Marzocchi M - - 1990
Patients using diaphragm pacemakers have several respiratory-related problems placing them at high risk for death during sleep, including central hypoventilation, abnormal arousal responses, upper airway and/or tracheostomy obstruction, and, in the case of high quadriplegia, lack of motor response to airway obstruction. The recent death from airway obstruction of a ...
Chen D - - 1990
The use of transcutaneous electrical nerve stimulation (TENS) has increased in recent years for the management of chronic pain. One of its few contraindications is the presence of a cardiac pacemaker. Clinicians have recommended that cardiac monitoring be performed for a short interrupted period during the first application of TENS ...
Glazer H S - - 1989
The appearance of pneumothorax on lateral radiographs obtained with the patient erect were reviewed in 100 patients (122 total examinations). A pneumothorax could be seen on the lateral projection in 89% of the examinations (109 of 122). The displaced pleural line was most frequently identified anteriorly or posteriorly and was ...
Shandling A H - - 1989
The physiological benefit of rate responsive, single-chamber cardiac pacing is well documented. We studied the activity response of nine atrially placed Activitrax II pacemakers. Seven patients were noted to have an inadequate activity-rate response with maximal pacing rates of 85 to 101 beats/min. Marker Channel analysis revealed that the upper ...
Bocka J J - - 1989
The concept of transcutaneous external cardiac pacing has been present for approximately 200 years. However, it was not until the early 1950s that transcutaneous pacing was practical. Implantable pacemakers were introduced in the late 1950s, superceding the more cumbersome and uncomfortable external models. Recent technologic improvements and the development of ...
Rubio P A - - 1989
In the following simplified method for inserting temporary pacemaker electrodes, the cardiac pacing wire itself is used as a suture. This quick, atraumatic technique allows for extra-secure placement, provides excellent electrode contact, and prevents accidental dislodgement, even during cardiopulmonary resuscitation. Because removal of the electrodes is not necessary, complications associated ...
Van Hemel N M - - 1989
Transient programmed upper limit stimulation (150 bpm) was observed during repetitively utilized electrocautery in the beginning of an open-heart surgical procedure in a patient with a minute ventilation rate responsive ventricular pacemaker. This tachycardia caused severe hemodynamic deterioration, and was also initiated by internal heart massage and manual ventilation. Considering ...
Combs W J - - 1989
Investigation of dual chamber pacing and sensing interactions at high rates is becoming increasingly important with the advent of sensor driven dual chamber pacemakers. The present study was designed to investigate the pacemaker and lead interactions that will affect cross-talk during high rate atrial and ventricular pacing. The study was ...
Wallenhaupt S L - - 1989
The availability of external atrioventricular sequential pacemakers has improved the management of patients with sinus bradycardia, junctional rhythm, and atrioventricular block. However, these pacemakers are of less value in patients with postoperative heart block and accelerated atrial rhythms. The temporary use of a modified explanted dual-chamber demand pacemaker may counteract ...
Howard P J - - 1989
Dysphagia is a frequent cause of referral for oesophageal manometry although the motor response to eating is not routinely studied. We examined symptoms and oesophageal motor patterns in response to eating bread in 30 patients with either gastro-oesophageal reflux (n = 20), or normal oesophageal function tests (n = 10). ...
Madsen G M - - 1989
Pacemakers with a rate-responsive function, based on calculation of ventilatory minute volume, may induce tachycardia in patients who undergo hyperventilation during general anaesthesia. If hyperventilation is desired, it is recommended that the pacemaker is reprogrammed in order to avoid tachycardia. If the programming device is not available, a magnet may ...
Mickley H - - 1989
Runaway pacemaker is a rare, but still existing potential lethal complication in permanent pacemakers. Within 4 1/2 years, we saw two cases of runaway pacemaker in patients with multiprogrammable, VVI pacemakers (Siemens-Elema, Model 668). In both cases a pacemaker-induced ventricular tachycardia (rate 240-260 beats/min) was documented. One patient died. Runaway ...
Suzuki Y - - 1989
A noninvasive heart rate (HR) monitoring system for avian embryos has been developed based on the ballistocardiogram (BCG). The BCG was detected using a phonograph cartridge as a record of the velocity of the minute ballistic movements of the eggshell, which are generated by recoil and impact of heart contraction ...
Ahlfeldt H - - 1989
Modulation of ventricular parasystole by sinus beats has been shown to result in a biphasic phase response curve. Some reports also indicate that the modulation effect could be described by a triphasic response with an early phase of acceleration, which would correspond to the supernormal phase of excitability. Two cases ...
Ellestad M H - - 1989
Since July 1980, 90 patients have had 95 permanent pacemakers implanted via an iliac vein approach. An incision is made superior to the inguinal ligament and the iliac vein is cannulated with a single lead for the ventricle or two leads for the atrium and ventricle. The pulse generator is ...
Morris D C - - 1989
Using a percutaneous femoral vein approach under fluoroscopic control, a malpositioned ventricular pacemaker electrode was released from the right ventricular wall by hooking the lead with a deflecting wire inserted into a RIM catheter. A closed loop was formed by tightening the handle of the wire allowing the electrode to ...
Robles de Medina E O - - 1989
The electrocardiograms of 2 patients with frequent premature ventricular complexes characterized by variable coupling intervals and fusions with sinus activations were analyzed according to the modulated parasystole and reflection hypotheses of Moe et al. In addition, the ectopic activity was associated with couplets, tachycardia and ventricular fibrillation. Departures from the ...